This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See the “Installation
Requirements” section for further notes.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration
in these installation instructions.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
follow instructions.
You
instructions.
W11209522C
can be killed or seriously injured if you don't
follow
INSTALLATION REQUIREMENTS
Tools and Parts
Tools needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
■ Measuring tape
■ Pencil
■ Masking tape or
thumbtacks
■ Scissors
■ No. 3 Phillips screwdriver
for ¼- 20 x 3" bolts
■ Drill
3
■
/16" (5 mm), 3/8" (10 mm),
5
/8" (16 mm) drill bits
3
■
/4" (19 mm) hole saw
Parts supplied
For information on reordering, see the “Replacement Parts”
section.
NOTE: The hardware items listed here are for wood studs. For
other types of wall structures, be sure to use appropriate
fasteners.
A
B
C
J
■ Diagonal wire cutting
pliers
■ Stud finder
7
■
/16" socket wrench
(or box wrench) for
1
/4" x 2" lag screws
■ 1½" (3.8 cm) diam. hole
drill bit for wood or metal
cabinet
■ Keyhole saw
■ Caulking gun and
weatherproof caulking
compound
■ Duct tape
DEF
H
G
Materials Needed
Standard fittings for wall or roof venting. See the “Venting Design
Specifications” section.
Location Requirements
IMPORTANT: Check the opening where the microwave oven will
be installed. The location must provide:
■ Minimum installation dimensions. See the “Installation
Dimensions” illustration.
■ Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum 3/8" (10 mm) thickness drywall or plaster/lath within
cabinet opening.
■ Support for weight of 150 lbs (68 kg) which includes
microwave oven and items placed inside the microwave
oven and upper cabinet.
■ Grounded electrical outlet inside upper cabinet. See the
“Electrical Requirements” section.
NOTES:
■ If installing the microwave oven near a left sidewall, make
sure there is at least 6" (15.2 cm) of clearance between the
wall and the microwave oven so that the door can open fully.
■ Some cabinet and building materials are not designed to
withstand the heat produced by the microwave oven for
cooking. Check with your builder or cabinet supplier to make
sure that the materials used will not discolor, delaminate, or
sustain other damages.
Special Requirements
For Wall Venting Installation Only:
■ Cutout must be free of any obstructions so that the vent fits
properly and the damper blade opens freely and fully.
For Roof Venting Installation Only:
■ If you are using a rectangular-to-round transition piece, the
3" (7.6 cm) clearance needs to exist above the microwave
oven so that the damper blade can open freely and fully. See
“Rectangular to Round Transition” illustration in the “Venting
Design Specifications” section.
A.3/16-24 x 3" round-head bolts (2)
B. 1/4-20 x 3" flat-head bolts (2)
C. Washers (2)
D.3/16" toggle nuts (2)
E. 1/4" x 2" lag screws (2)
F. Sheet metal screws 5/32" x 5/16"
(0.4 cm x 0.8 cm) (2)
G. Power supply cord bushing (1)
H. Damper assembly (for wall or roof
venting)
J. Vent cover (2)
Not Shown:
■ Mounting plate
(Located on the upper
polyfoam)
■ Grease filters
■ Charcoal filters
NOTE: Depending on model, grease filter and charcoal filter may
be combined.
2
Installation Dimensions
A B
Bump out mounting
bracket
14"
12"
DEEPER
15"
14"
DEEPER
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See the “Electrical Requirements” section.
12" (30.5 cm) min.
14" (35.6 cm) max.
upper cabinet and
side cabinet depth
60" ( 152.4 cm) min.
30"
(76.2 cm)
min.
24"
(61 cm)
typical*
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Observe all governing codes and ordinances.
Required:
■ A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply with a
fuse or circuit breaker
Recommended:
■ A time-delay fuse or time-delay circuit breaker
■ A separate circuit serving only this microwave oven
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
*24” (61 cm) is typical for 60” (152.4 cm) installation height.
Exact dimensions may vary depending on type of range/
cooktop below.
NOTE: To ensure good performance, do not obstruct top vent
airflow. If cabinets are deeper than 14" (35.6 cm) but no more
than 15" (38.1cm), use the bump out mounting kit replacing the
mounting plate from the wall. The bump out mounting kit
(part # W11185746) is not provided but can be purchased from
Whirlpool.
mounting plate
Product Dimensions
*Overall depth of product will vary slightly depending on door
design.
GROUNDING INSTRUCTIONS
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING:Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS
"
/
10
26.2cm
18"
45.5cm
29
" (76.0 cm)
⁄
/
10
26.2cm
"
3
A
BCD
A
B
A
C
D
Charcoal filter
INSTALLATION INSTRUCTIONS
Wall Venting Installation Only
1. Using diagonal wire cutting pliers, gently snip out the
rectangular vent cover on the damper plate.
A
A. Diagonal wire cutting pliers
B. Damper vent covers
B
Install Damper Assembly
(for wall venting only)
1. Check that damper blade moves freely, and opens fully.
2. Position the damper assembly on the back of the microwave
oven so that the damper blade hinge is at the top, and the
damper blade opens away from the microwave oven.
Install Damper Assembly
(for roof venting only)
1. Check that damper blade moves freely, and opens fully.
2. Position the damper assembly on the top of microwave oven
so that the damper blade hinge is at the top, and the damper
blade opens away from the microwave oven.
B
A. Screws
B. Damper assembly
C Damper blade
D Top of the microwave oven
3. Secure damper assembly with 2 Sheet metal screws
5
/32" x 5/16" (0.4 cm x 0.8 cm).
Note: To ensure good performance of airflow, for Wall and Roof
venting, remove the charcoal filter from the bottom plate before
operating the microwave oven.
A. Back of microwave oven
B. Damper assembly
C. Damper blade
D. Sheet metal screw 5/32" x 5/16"
(0.4 cm x 0.8 cm)
3. Secure damper assembly with 2 Sheet metal screws
5
/32" x 5/16" (0.4 cm x 0.8 cm).
Roof Venting Installation Only
1. Remove screws attaching damper plate to top of microwave
oven exterior. Slide damper plate toward the front of the
microwave oven and lift up.
4
A. Screws
B. Damper plate
Grease filter
Vent Cover Installation
E
A
E
(for both upper vent and wall vent installation)
1. Remove screws attaching vent cover B, C and D to top of
microwave exterior. Slide out vent covers B, C and D.
Keep the vent cover C for step 2 use.
A
2. Place the vent cover C (removed from step 1) to the first
position to the left and rotate it 180 degrees.
C
B
C
D
A. Screws
B. Vent Cover
C. Vent Cover
D. Vent Cover
E. Top front of the
microwave
NOTE: Keep the vent cover B and vent cover D for recirculation
in future.
3. Remove the vent covers located in the upper polyfoam (see
item J in "Parts Supplied" section).
4. Attach the vent covers to vents B & C using the screws
removed in step 1.
B
C
A. Screw
B. Vent cover (located
in upper polyfoam)
C. Vent cover (located
in upper polyfoam)
E. Top front of the
microwave
Locate Wall Stud(s)
NOTE: If no wall studs exist within the cabinet opening, do not
install the microwave oven.
See illustrations in “Possible Wall Stud Configurations.”
1. Using a stud finder, locate the edges of the wall stud(s)
within the opening.
2. Mark the center of each stud and draw a plumb line down
each stud center. See illustrations in “Possible Wall Stud
Configurations.”
5
Possible Wall Stud Configurations
C
F
D
Figure 1
C
F
D
Figure 3
E
F
Figure 2
These depictions show examples of preferred installation configurations with the mounting plate.
No Wall Studs at End Holes
B
D
A
E
C
A
E
No Wall Studs at End Holes
B
A
C
A
E
D
NOTE: If wall studs is within 6" (15.2 cm) of the vertical centerline (see "Mark Rear Wall" section), only recirculation or roof venting
installation can be done.
Wall Studs at End Holes
B
D
A
E
A. End holes (on mounting plate)
B. Cabinet opening vertical centerline
C. Wall stud centerlines
D. Holes for lag screws
E. Support tabs
F. Mounting plate center markers
A,
C
E
6
Wall Studs at End Holes
Figure 4
A,D
F
D
A
B
B
E
C
A. End holes (on mounting plate)
B. Cabinet opening vertical centerline
C. Wall stud centerlines
D. Holes for lag screws
E. Support tabs
F. Mounting plate center markers
Prepare Upper Cabinet
You can find the quick reference guide direct from the mounting
plate marking, or use this installation guide for installation.
See below install steps:
1. Disconnect power to outlet.
2. Remove all contents from upper cabinet.
3. Mark centerline on bottom of upper cabinet. Place mounting
plate against the bottom of the upper cabinet. Make sure the
mounting plate centerline aligns with the vertical centerline
on the rear wall.
The “Rear wall” arrows must be against the rear wall so that
the holes cut into the upper cabinet align with the holes in
the top of the microwave oven.
Note: If the wall behind the microwave oven (as installed) has a
partial wall covering (for example, tile backslash), be sure the
“Rear Wall” arrows align to the thickest part of the rear wall (for
example, the thickness of the tiles rather than the drywall).
A,
C
E
D
G
E
t
Note: If upper cabinet is metal, the supply cord bushing needs
to be installed around the supply cord hole as shown.
A
A. Metal cabinet
B. Power supply cord bushing
A. Centerline
4. Make sure the 10 3/4"(27.3 cm) dimension from the rear wall
to points “D” and “E” on the template is maintained.
5. Place mounting plate against the bottom of upper cabinet
line and mark power supplier hole, cut the 1¹⁄2" (3.8 cm)
diameter hole at the circular shaded area “G” on the
6. Drill 3/8" (10 mm) holes at points “D” and “E” on the
template. These are for two 1⁄4-20 x 3" bolts and washers
used to secure the microwave oven to the upper cabinet.
Note: If replacing a range hood that has the direct wire power
supply coming from the wall, install outlet box accessory kit
in upper cabinet. The Outlet Box Kit (part #W11082816) is not
provided but can be purchased from Whirlpool.
template. This hole is for the power supply cord.
7
Roof Venting Installation Only
Fold Forward
A
A1
A2
7. If venting through the roof, mark and trace the corner
punches on the mounting plate. Set mounting plate aside,
cut the venting area out from the bottom of the upper
cabinet using a keyhole saw.
3. Align the center markers on the mounting plate to the
centerline of the wall. Make sure it is leveled and top of the
mounting plate is butted up against the bottom edge of the
upper cabinet.
NOTE: If the front edge of the upper cabinet is lower than the
back edge, lower the mounting plate so that its top is leveled
with the front edge of the cabinet.
D
4 Corners
Mark Rear Wall
The microwave oven must be installed on a minimum of 1 wall
stud, preferably 2, using a minimum of 1 lag screw, preferably 2.
1. Fold 2 mounting tabs forward into the tab cutout. Note that
the tabs will NOT be flush after folding.
2. Mark centerline on the back wall. Place mounting template
against the back wall, find and clearly mark the vertical
centerline of the opening.
C
B
A. Rear wall
B. Mounting Template
C. Top of mounting template must
align with front edge of cabinet
D. Front edge of upper cabinet
Wall Venting Installation Only
4. If venting through the wall, place mounting plate on the wall
and mark the cut-out area. Set mounting plate aside, then
using a keyhole saw, cut out hole in the wall at back venting
area.
Cut-out area for
BACK WALL Venting
B1
B2
A
A. Centerline
8
Drill Holes in Rear Wall
A
B
A
B
In addition to being installed on at least 1 wall stud, the
mounting plate must attach to the wall at both end holes. If the
end holes are not over wall studs, use two 3/16-24 x 3” round
head bolts with toggle nuts; if 1 end hole is over a wall stud, use
1 lag screw and one 3/16-24 x 3” round-head bolt with toggle
nut; or if both end holes are over wall studs, use 2 lag screws.
Following are 3 installation configurations.
2. Start toggle nuts on bolts from the back of the mounting
plate. Leave enough space for the toggle nuts to go
through the wall and to open.
Installation for No Wall Studs at End Holes (Figures 1
and 2)
1. Drill 5/8” (16 mm) holes through the wall at both end holes
marked in Step 3 of “Mark Rear Wall.”
2. Drill 3/16” (5 mm) hole(s) into the wall stud(s) at the hole(s)
marked in Step 6 of “Mark Rear Wall.” Refer to figures 1 and
2 in “Possible Wall Stud Configurations” in the “Locate Wall
Stud(s)” section.
Installation for Wall Stud at One End Hole (Figure 3)
1. Drill a 3/16” (5 mm) hole into the wall stud at the end hole
marked in Step 3 of “Mark Rear Wall.”
2. If installing on a second wall stud, drill a 3/16” (5 mm) hole
into the wall stud at the other hole marked in Step 6 of
“Mark Rear Wall.” Refer to Figure 3 in “Possible Wall Stud
Configurations” in the “Locate Wall Stud(s)” section.
3. Drill a 5/8” (16 mm) hole through the wall at the other end
hole.
Installation for Wall Studs at Both End Holes
(Figure 4)
1. Drill 3/16” (5 mm) hole into the wall stud at the end hole
marked in Step 3 of “Mark Rear Wall.
Attach Mounting Plate to Wall
NOTE: Secure the mounting plate to the wall at both end holes
drilled into the wall studs and/or drywall using either
round-head bolts and toggle nuts or
1/
4
" x 2" lag screws.
Refer to illustrations in “Possible Wall Stud Configurations” in the
“Locate Wall Stud(s)” section.
For fast wall and roof vent installation, see the quick reference
guide on the mounting plate.
No Wall Studs at End Holes (Figures 1 and 2)
NOTE: The mounting plate must be secured to the wall on at
least 1 wall stud as well as at both ends.
1. With the support tabs of the mounting plate facing forward,
3/
16
insert
-24 x 3" round-head bolts through both end holes of
mounting plate.
3/
16
-24 x 3"
C
A. 3/16-24 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
3. Position mounting plate on the wall.
4. Push the 2 bolts with toggle nuts through the drywall and
finger tighten the bolts to make sure toggle nuts have
opened against drywall.
C
D
A. 3/16-24 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
D. Drywall
5. Insert lag screw(s) into the hole(s) drilled into wall stud(s) in
Step 2 of “Installation for No Wall Studs at End Holes” in the
“Drill Holes in Rear Wall” section.
6. Check alignment of mounting plate, making sure it is level.
7. Securely tighten all lag screws and bolts.
Wall Stud at One End Hole (Figure 3)
1. With the support tabs of the mounting plate facing forward,
insert a
fits over the
for Wall Stud at One End Hole” in the “Drill Holes in Rear
Wall” section.
2. Start a toggle nut on the bolt from the back of the mounting
plate. Leave enough space for the toggle nut to go through
the wall and to open.
3. Position mounting plate on the wall.
4. Push the bolt with toggle nut through the drywall and finger
tighten the bolt to make sure toggle nut has opened against
drywall.
5. Insert a lag screw into the remaining end hole.
6. If installing on a second wall stud, insert a lag screw into
the other hole drilled in Step 2 of “Installation for Wall Stud
at One End Hole” in the “Drill Holes in Rear Wall” section.
Check alignment of mounting plate, making sure it is level.
7. Securely tighten the lag screw(s) and bolt.
3/
16
-24 x 3" round-head bolt through the end hole that
5/
8
" (16 mm) hole drilled in Step 3 of “Installation
Wall Studs at Both End Holes (Figure 4)
1. Position mounting plate on the wall.
2. Insert lag screws into both end holes.
3. Check alignment of mounting plate, making sure it is level.
4. Securely tighten the lag screws.
9