KitchenAid YGH8155XMB1, YGH8155XMB2, YKHMS155LWH2, YKHMS155LBL2, YKHMS155LBT2 Installation Guide

...
MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide. These installation instructions cover different models. The appearance of your particular model may differ slightly from the
illustration in these installation instructions. NOTES:
Proper installation isthe responsibility of the installer.
Product failure dueto improper installation is not coveredunder the warranty.
DEL'ENSEMBLEFOUR MICRO-ONDES/HOTTE
Ce produit est congu pour I'utilisation au-dessus d'appareils de cuisson 61ectriques ou _.gaz de 36" (91,4 cm) de largeur
ou moins.
Ces instructions d'installation sent valables pour plusieurs mod_les. IIse peut que I'apparence de votre propre mod_le soit 16g_rement diff6rente de celle montr6e sur les illustrations dans ce document.
REMARQUES :
C'est &I'installateur qu'il incombe de realiserune installation correcte.
Lesdefaillances duproduit dues &une installation incorrecte nesent pas couvertes par lagarantie.
Table of Contents / Table des mati@res
MICROWAVE HOOD COMBINATION SAFETY ......................... 2
VENTING DESIGN SPECIFICATIONS ......................................... 2
INSTALLATION REQUIREMENTS .............................................. 3
Tools and Parts .......................................................................... 3
Location Requirements .............................................................. 4
Product Dimensions ................................................................... 4
Electrical Requirements ............................................................. 5
INSTALLATION INSTRUCTIONS ................................................ 5
Remove Mounting Plate ............................................................ 5
Rotate Air Deflector .................................................................... 5
Locate Wall Stud(s) .................................................................... 7
Mark Rear Wall ........................................................................... 8
Drill Holes in Rear Wall ............................................................... 8
Attach Mounting Plate to Wall ................................................... 9
Prepare Upper Cabinet .............................................................. 9
Install Damper Assembly ........................................................ 10
Installthe Microwave Oven ..................................................... 10
Complete installation .............................................................. t 2
ASSISTANCE .............................................................................. 12
Replacement Parts.................................................................. t 2
Accessories ............................................................................. 12
SleCURITle DE L'ENSEMBLE FOUR .&MICRO-ONDES/HOTTE....13
SPleCIFICATIONS/CONCEPTION DU CIRCUIT D'IeVACUATION .13
EXIGENCES D'INSTALLATION ......................................................... 15
Outillage et pieces ........................................................................... t 5
Exigenees d'emplacement .............................................................. 15
Dimensions du produit ..................................................................... t6
Specifications _lectriques ................................................................ t6
INSTRUCTIONS D'INSTALLATION ................................................... 17
D_pose de la plaque de montage ................................................... 17
R_orientation du d_flecteur d'air ..................................................... 17
Identifier la position du/des poteaux du colombage mural ............ 19
Trac_ sur lemur arriere .................................................................... 20
Percage de trous dans lemur arri_re .............................................. 20
Fixation de la plaque de montage sur le mur .................................. 21
Preparation du placard mural .......................................................... 22
Installation du module du clapet anti-reflux .................................... 22
Installation du four & micro-ondes ................................................... 22
Achever I'installation ........................................................................ 24
ASSISTAN CE ...................................................................................... 24
Pieces de rechange ......................................................................... 24
Accessoires ...................................................................................... 24
IMPORTANT: Read Installation Instructions thoroughly before beginning installation. Save Installation Instructions for local house inspector's use.
IMPORTANT : Lire completement les instructions d'installation avant de commencer I'installation. Conserver ces instructions d'installation & I'usage de I'inspecteur local des installations de la maison.
8206197
MICROWAVE HOOD COMBINATION SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
VENTING DESIGN SPECIFICATIONS
This section is intended for architectural designer and builder/contractor reference only.
NOTES:
Vent materials needed for installation are not provided with microwave hood.
We do not recommend using a flexible metal vent. Toavoid possible product damage, be sure to vent air outside,
unless using ventless (recirculating) installation. Do not vent exhaust air into concealed spaces, such as spaces within walls or ceilings, attics, crawl spaces or garages.
For optimal venting installation, we recommend:
using roof or wall caps that have back draft dampers
using a rigid metal vent
using the most direct route by minimizing the length of the vent and number of elbows to provide efficient performance
using uniformly sized vents
using duct tape to seal all joints in the vent system
using caulking compound to seal exterior wall or roof opening around cap
not installing 2 elbows together, for optimal hood performance
If venting through the wall, be sure that there is proper clearance within the wall for the damper to open fully.
If venting through the roof, and rectangular to round transition is used, be sure there is at least 3" (7.6 cm) of clearance between
the top of the microwave oven and the transition piece. See "Rectangular to Round Transition" illustration.
Roof venting Roof cap
Wall venting Wall cap
Rectangular to Round Transition NOTE: The minimum 3" (7.6 cm) clearance must exist between
the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
3W' x 10" (8.3 x 25.4 cm) vent system = 73ft (22.2 m) total
A B
i_( 6ft (1.8 m) _
2 ft TI I
(0.6m)
B C
E
3" (7.6 cm)
F
t
A. Roof cap B. 6" (15.2 cm) min. diameter round vent C. Elbow (for wall venting only) D. Wall cap
E. 3¼" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)
rectangular to round transition piece
F Vent extension piece, at least 3" (7.6 cm) high
Recommended Standard Fittings
The following length equivalents are for use when figuring vent length. See the examples in "Recommended Vent Length."
A B C
C
A. One 3 ¼" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
B. 1wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A
I,_ 6 ft (1.8 rn)
B
................................................................................
C D
A. Two 90° elbows = 20 ft (6.1 m) B. 1 wall cap = 40 ft (12.2 m)
C. 1rectangular to round transition piece = 5 ft (1.5 m) D. 2 ft (O.6 m) + 6 ft (1.8 m) straight = S ft (2.4 m)
Ifthe existing vent is round, a rectangular to round transition piece must be used. In addition, a rectangular 3" (7.6 cm) extension vent
between the damper assembly and rectangular to round transition piece must be installed to keep the damper from sticking.
E F G
A. Rectangular to round transition piece: 3 ¼" x 10" to 6" =5 ft
(8.3 x 25.4 cm to !5.2 cm = 1.5 m) B. Roof cap: 3 ¼" x 10" =24 ft (8.3 x 25.4 cm = 7.3 m) C. 90° elbow: 3 ¼" x 10" =25 ft (8.3 x 25.4 cm = 7.6 m) D. 90 ° elbow: 6" = !0 ft (15.2 cm = 3 m)
E. Wall cap: 3¼" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m) F. 45 ° elbow: 6" = 5 ft (15.2 cm = 1.5 m)
G. 90 ° flat elbow: 3¼" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
Recommended Vent Length
A 3W' x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.
The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. See
"Recommended Standard Fittings" section for equivalent lengths. For best performance, use no more than three 90° elbows. Tocalculate the length of the system you need, add the equivalent
lengths of each vent piece used in the system. See the following examples:
INSTALLATION
REQUIREMENTS
Tools Needed
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools
listed here.
Measuring tape
Pencil
Masking tape or thumbtacks
Scissors
No. 2 Phillips screwdriver
No. 3 Phillips screwdriver for 1/4-20 x 3" round-head bolts
Electric drill 3/16" (5 mm), 3/8" (10 mm)
drill bits
3/4" (19 mm) hole saw
Stud finder 7116" socket wrench
(or box wrench) for 1/4" x 2" lag screws
1W' (3.8 cm) diam. hole drill
bit for wood or metal cabinet
Keyhole saw
Caulking gun and weatherproof caulking
compound
Duct tape
PartsSupplied Forreorderinformation,see"ReplacementParts"section. NOTE:Thehardwareitemslistedhereareforwoodstuds.For othertypesofwallstructures,besuretouseappropriate
fasteners.
Special Requirements
For Wall Venting Installation Only:
The 12" x 4" (30.5 x 10.2 cm) cutout area must align with the rectangular hole in the mounting plate.
Cutout must be free of any obstructions so that the vent tube fits properly, and the damper blade opens freely and fully.
For Roof Venting Installation Only:
If using rectangular to round transition piece, the 3" (7.6 cm) clearance needs to exist above the microwave oven so that
the damper blade can open freely and fully. See "Rectangular to Round Transition" illustration in "Venting Design
Specifications" section.
Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See "Electrical Requirements" section.
A B
A. 1/4-20 x 3" bolts (6) B. Washers (2) C. Toggle nuts (4) D. 1/4" x 2" lag screws (4)
E. Power supply cord bushing (!) F Damperassembly (for wall or roof
venting)
NOTE: Depending on model, aluminum grease filter and charcoal filter may be combined.
Materials needed
Standard fittings for wall or roof venting. See "Venting Design Specifications" section.
Check the opening where the microwave oven will be installed. The location must provide:
Minimum installation dimensions. See "Installation Dimensions" illustration.
Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and minimum 3/8" (9.5 mm) thickness drywall or plaster/lath within cabinet opening.
Support for weight of 150 Ibs (68 kg), which includes microwave oven and items placed inside the microwave oven and upper cabinet.
Grounded electrical outlet inside upper cabinet. See "Electrical Requirements" section.
NOTES:
If installing the microwave oven near a left sidewall, make sure *_ there is at least 6" (15.2 cm) of clearance between the wall and
the microwave oven, so that the door can open fully.
Some cabinet and building materials are not designed to 16w' withstand the heat produced by the microwave oven for (41.3cm)
cooking. Check with your builder or cabinet supplier to make | sure that the materials used will not discolor, delaminate or
sustain other damages.
Not Shown:
Upper cabinet template
Mounting plate (attached to back of microwave oven)
Aluminum grease filters Charcoal filters (Depending
on model, charcoal filters may not be included. See
Use and Care Guide.)
66" (167.6 cm) rain.
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop below.
/
l
u ...........
30" (76.2 cm) typ!cal*
_ 12" (36.5 cm) rain.
14" (35.6 cm) max.
-_@_ .....
__ : ::::;: r:z:: ::: :
A.2" x 4" wallstud B. Grounded3 prong outlet
t
15"
[38.1 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
Observe all governing codes and ordinances. Required: [] A 120 Volt, 60 Hz, AC only, 15- or 20-amp electrical supply
with a fuse or circuit breaker.
Recommended: [] A time-delay fuse or time-delay circuit breaker.
[] A separate circuit serving only this appliance.
GROUNDING INSTRUCTIONS
[] For all cord connected appliances:
The microwave oven must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed
and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS
INSTALLATIONINSTRUCTIONS
NOTE: To avoid possible damage to the work surface, place a protective cover on the work surface.
1. Remove any remaining contents from the microwave oven cavity.
2. Remove the mounting plate by peeling off the strips of tape that attach it to the back of the microwave oven, and set the
mounting plate aside.
A B C
®® ®o ®o
® ® /e
e e eemeeoeeoeeeeeoeeoeee_ee e
0"_ ...................... _0
® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ®
A. Back of microwave oven B. Mounting plate
C. Tape (multiple locations)
3. Tape microwave oven door closed so that door does not swing open while microwave oven is being handled.
NOTE: Do not grip or use the door or door handle while the microwave oven is being manipulated.
%oteb Def eckx'
The microwave oven is set for ventless (recirculating) installation. For wall or roof venting, changes must be made to the venting
system. NOTE: Skip this section if you are using ventless (recirculating)
installation. Keep the damper assembly in case the venting method is changed, or the microwave oven is reinstalled in
another location where wall or roof venting may be used.
Wall Venting Installation Only
1. Remove 5 screws attaching damper plate to top of microwave oven exterior, then lift off damper plate.
A
A. Damperplate
2. Keep damper plate and screws together and set aside.
3. Slideairdeflectoroutofmicrowaveoven.
A.Air deflector
4.
Rotate air deflector front to back so that deflector vanes face the back of the microwave oven, and the exhaust port (open
end) of air deflector aligns with microwave oven exhaust port.
A
A. Microwave oven exhaust port B. Air deflector exhaust port (open end) C. Deflector vanes
Roof Venting Installation Only
1.
Repeat Step 1 from "Wall Venting Installation Only."
2.
Repeat Step 2 from "Wall Venting Installation Only."
3.
Repeat Step 3 from "Wall Venting Installation Only."
4.
Rotate air deflector so that deflector vanes face the top of the microwave oven, and the exhaust port (open end) of air
deflector aligns with microwave oven exhaust port.
A
A. Microwave oven exhaust port B. Deflector vanes
C. Air deflector exhaust port (open end)
5=
Slide air deflector into the back of the microwave oven as shown, making sure its exhaust port (open end) aligns with the
microwave oven exhaust port.
5=
Slide air deflector into the back of the microwave oven as shown, making sure its exhaust port (open end) aligns with the
microwave oven exhaust port.
A
C
A. Microwave oven exhaust port B. Air deflector exhaust port (open end)
C. Deflector vanes
6. Reattach damper plate with screws.
A. Microwave oven exhaust port B. Deflector vanes
C. Air deflector exhaust port (open end)
6=
Reattach damper plate at corners with 4 screws. Save the fifth screw for later use.
Lx}c@e S ud(s}
NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within install the microwave oven, the opening.
See illustrations in "Possible Wall Stud Configurations," 2. Mark the center of each stud, and draw a plumb line down
Possible Wall Stud Configurations
These depictions show examples of preferred installation configurations with the mounting plate.
each stud center. See illustrations in "Possible Wall Stud Configurations."
No Wall Studs at Corner Holes
Figure 1
_i_ _i_
One Wall Stud at Two Corner Holes
Figure3
No Wall Studs at Corner Holes
Figure2
,ii'
i i I
i i
i i
NOTE: If wall stud is behind vent opening, only ventless (recirculating) or roof venting installation can be done.
Wall Studs at All Four Corner Holes
Figure4
.D
A. Corner holes (on mounting plate) B. Cabinet opening vertical centerllne
C. Wall vent opening (on mounting plate) D. Wall stud centerllnes
E. Holes for lag screws
F. Support tabs
G. Mounting plate center markers
The microwave oven must be installed on a minimum of I wall stud, preferably 2, using a minimum of 1 lag screw, preferably 2 or
more.
1. Using measuring tape, find and clearly mark the vertical centerline of the opening.
A. Centerline
2. With the support tabs facing forward (see illustrations in "Possible Wall Stud Configurations" in "Locate Wall Stud(s)"
section), align the mounting plate center markers to the centerline on the wall, making sure it is level, and that the top of the mounting plate is butted up against the bottom edge of the upper cabinet.
NOTE: If the front edge of the upper cabinet is lower than the back edge, lower the mounting plate so that its top is level with the front edge of the cabinet.
Wall Venting Installation Only
Centeriine
Upper Cabinet Bottom
J
t
4" (10.2 cm)
IP
6" (15.2 cm) 6" (15.2 cm)
6. Mark the centerline 3/8" (1cm) down from the bottom edge of the upper cabinet.
7. Using measuring tape, measure out 6" (15.2 cm) on both sides of the centedine, and mark.
8. Measure down 4" (10.2 cm) from the mark made in Step 6, and mark.
9. Using a straightedge, draw the 2 horizontal, level lines through the marks made in steps 6 and 8.
10. Draw the 2 vertical, plumb lines down from the marks made in Step 7 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle.
This is the venting cutout area.
11. Cut a 3/4" (19 mm) hole in one corner of the cutout area.
12. Using a keyhole saw, cut out the venting cutout area.
A ........
C
B
A. Rear wall
B. Mounting plate C. Top of mounting plate must align
with front edge of cabineL
D. Front edge of upper cabinet
3. Holding the mounting plate in place, mark the 4 corner holes.
4. Find the wall stud centerline(s) marked in Step 2 of "Locate Wall Stud(s)," and mark at least 1, preferably 2 or more, hole(s)
through the mounting plate, closest to the centerline(s). See figures 1, 2 and/or 3 in "Possible Wall Stud Configurations" in "Locate Wall Stud(s)" section. The blackened holes in the
shaded areas are ideal hole locations.
5. Set mounting plate aside.
In addition to being installed on at least 1wall stud, the mounting plate must attach to the wall at all 4 corner holes. If the holes are not over wall studs, use four 1/4-20 x 3" round-head bolts with
toggle nuts; if 2 holes are over wall studs, use 2 each of lag screws and 1/4-20 x 3" round-head bolts with toggle nuts; or if all
4 holes are over wall studs, use 4 lag screws. Following are 3 installation configurations.
Installation for No Wall Studs at Corner Holes (Figures 1 & 2)
1. Drill 3/4" (19 mm) holes through the wall at all 4 corner holes marked in Step 3 of "Mark Rear Wall."
2. Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s) marked in Step 4 of "Mark Rear Wall." Refer to figures 1 and 2 in "Possible Wall Stud Configurations" in "Locate Wall Stud(s)"
section.
Installation for One Wall Stud at Two Corner Holes (Figure 3)
1. Drill 3/16" (5 mm) holes into the wall stud at the 2 corner holes marked in Step 3 of "Mark Rear Wall."
2. If installing on a second wall stud, drill 3/16" (5 mm) hole(s) into the wall stud at the holes marked in Step 4 of "Mark Rear
Wall." Refer to Figure 3 in "Possible Wall Stud Configurations." in "Locate Wall Stud(s)" section.
3. Drill 3/4" (19 mm) holes through the wall at the other 2 corner holes.
Installation for Wall Studs at All Four Corner Holes
(Figure 4)
1. Drill 3/16" (5mm)holes into the studs at the 4 corner holes marked in Step 3 of "Mark RearWall."
Loading...
+ 16 hidden pages