KitchenAid YKGRC608LS0, KGSC308LSS0, KGRC707LWH0, KGRC608LSS0, KGRC707LBL0 Installation Guide

...
HOME APPLIANCES
Tip Over Hazard
A child or adult can tip the range and be killed.
Reconnect the anti=tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
o ®
9758639
R
Part No. 9758639
I
a
these
iMPORTANT : Installer: Leave installation instructions
with the homeowner.
Homeowner: Keep installation
instructions and anti:tip bracket template for future reference.
Save installation Instructions for local
electrical inspector's use.
O_So
30" (76.2
F
\
with semf-cmeaning thermal/convection oven
Before you start...
Your safety and the safety of others
are very important.
Wehaveprovided many important safety messagesin this manuaIand on your appliance. Always readand
obeyall safety messages.
This isthe safety aIert symb0i. This symb0t aierts you to potential hazards
that can kiii or hurt you and others.
Ati safety messageswiii f0ii0w the safety alert symbol
and eitherthe word "DANGER"or "WARNING". These
words mean:
Cabinet opening dimensions
25" (63.5 cm) countertop depth (with or without backsplash) and 24" (61 cm) base cabinet depth, 36" (91.4 cm) countertop height
Freestanding
"_ _3" (33 cm) max.
pper cabinet depth j _,_j. 18" (45.7 cm)
30" (76.2 cm) cabinet clearance to to countertop
///_...._ opening w_dth cooktop, see
30" (76.2 cm)
(7.3,,cm_.t.._,_ opening width
(22.9 cm)
For minimum upper side cabinet
***Note
Youcan be killed or sed0usly injured ifyou don't
f0H0w instructions.
AII safety messageswilI teli you what the p0tentiai
hazardis, teli you how to reduce the chance of injury,
and teii you what can happenif the instructions are not
followed.
WARNING: _fthe information in this
manual is not followed exactmy, a fire
or expmosion may resuJt causing
property damage, personal injury or
death.
- Do not store or use gasoline or other flammabme vapors and miquids in
the vicinity of this or any other
appliance.
-WHAT TO DO iF YOU SMELL GAS
o Do not try to _ight any appliance. o Do not touch any e_ectrica_ switch
o Do not use any phone in your
building.
4" (10.2 cm) min. clearance
from both sides of range to
side wall or other combustible material.
Gas line opening can be located within this
area.
2" (5.1 cm)__
! (I5.2 cm)
(25.4 cm) Outlet should be
2-1/2" (6.4 cm) 1
floor gas line "_\ _h._// opening if directly _ I - / below regulator
7/8" (2.2 cm) min.
required between
cabinet opening and door or hinge
opening.
located within the 18" x
10" (45.7 cmx 25.4 cm)
shaded area. 1
o Immediately call your gas supplier
from a neighbor's phone. Follow the gas supplier's instructions.
o if you cannot reach your gas
supplier, call the fire department.
- Installation and service must be
performed by a qualified instalmer, service agency or the gas supplier.
Countertop opening dimensions that are shown must be used. Given dimensions provide required
clearances. To eliminate the risk of burns or fire by reaching
over heated surface units, cabinet storage space located above the surface units should be avoided.
If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the
bottom of the cabinets. Read electrical and carpentry instructions.
Proper installation is your responsibility. A qualified technician must install this range. Make sure you have everything necessary for correct installation. It
is the customer's responsibility to make sure that the countertop has been properly prepared and that
the installation clearances specified on the model/serial rating plate are met. The model/serial rating plate is located on the oven frame behind the
oven drawer. Check location where range will be installed. The
range should be located for convenient use in the kitchen. Recessed installations must provide
complete enclosure of the sides and rear of range.
All openings in the wall or floor where range is to be
installed must be sealed. IMPORTANT: Some cabinet and building materials
are not designed to withstand the heat produced by the oven for baking and self-cleaning. Check with your builder or cabinet supplier to make sure that
the materials used will not discolor, delaminate or sustain other damage.
It is the customer's responsibility: To contact a qualified electrical installer.
Panel A
30" (76.2 cm)
opening width
4 (10 2 cm) mln
other combustible mater_i --\ _//
(22.9 cm)
3 _
(7.6 cm)
Gas line opening should be located within this
shaded area.
floor gas line opening if
directly below regulator
To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 -- latest edition*, or CSA Standard
C22.1, Canadian Electrical Code, Part 1 --latest
edition**, and all local codes and ordinances.
NOTE: This appliance is manufactured for use with Natural Gas. Conversion to LR Gas can be made
using the kit included in your literature package.
NOTE: The metal chassis of the range must be grounded in order for the control panel to work. If the metal chassis of the range is not grounded, no
keypads will operate. Check with a qualified electrician if you are not sure the range is grounded.
(15.
Rear vent must be installed on all slide-in
models for proper
ventilation. See Step 7,
Panel D.
IMPORTANT:
Outlet should be located within
(61 cm)
7/8" (2.2 cm) min. required between opening.
the 18" x 10" (45.7 x 25.4 cm)
shaded area.
pening and door or hinge
IMPORTANT: Observe all governing codes and
ordinances.
Grounded electrical outlet is required. See
"Electrical requirements," Panel C.
Cabinet opening dimensions that are shown must be used.
Do not pinch the power supply cord between the range and the wall.
Do not seal range to side cabinets.
Copies of the standards listed may be obtained from:
*National Fire Protection Association
One Batterymarch Park Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant'Valley Road Cleveland, Ohio 44131-5575
*** NOTE: 24" (61 cm) min. when bottom of wood or
metal cabinet is protected by not less than 1/4" (6.4 mm) flame retardant miltboard covered with not tess than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) rain. clearance between the top of the cooking platform and the bottom of an unprotected
wood or metal cabinet.
ran es:
for
countertop preparation
30 _
(76.2 cm)
opening,
width
1/2"
p"
30-7/8"
(78.4 cm) Formed or tiled countertop
. / trimmed 1/2" (1.3 cm)back
The cooktop sides of the siidedn range fit over the cutout edge of your countertop.
if you have a square finish (flat) countertop and
the opening width is 30" (76.2 cm), no
countertop preparation is required. Formed front-edged countertops: Must have
molded edge shaved flat 1/2" (1.3 cm) from
each front corner of opening. Tile countertops may need trim cut back
1/2" (1.3 cm) from each front corner andlor rounded edge flattened.
at front corners of countertop opening.
(63.5 cm)
Cooktop sides of range fit over edges of countertop opening.
if countertop opening width is greater than
30" (76.2 cm), adjust the 1/2" (1.3 cm) dimension.
Countertop must be level. Place level on
countertop, first side to side; then front to back.
if countertop is not level, range will not be level
Oven must be level for satisfactory baking
conditions.
ation:
Assemble the required tools and parts before starting
instaiJation. Read and follow the instructions provided
with any tooJs listed here.
level Phillips scewdriver
flat-blade screwdriver or 5/16""(7.9 mm) nut driver 3/8" ( 9.5 mm) ratchet adjustable wrench pliers
hammer measureing tape or ruler
hand or electric drill wood floor: 1/8" (0.3 cm) drill bit
concrete/ceramic floor: 3116" (0.48 cm) carbide- tipped masonry drill bit
LR gas conversion requires: pin pick up (claw attachment)
5/16" nut driver
arts sup
ied for
uct dimensions
Freestanding Range
30" (76.2 cm)
range width
36-1/8"
(91.8 cm)
cooktop
height
44-3/8"
(112.7 cm)
-4
n:
burner grates and caps
vent cap
LR conversion orifice spud kit: 1 - 0.95 mm (0.0374") cooktop (blue)
2 - 0.67 mm (0.0264") cooktop (bJack)
1 - 1.05 mm (0.0413") cooktop (green) 1 -#65 (0.0350") broil burner
anti)-tig
anchors
_ 2 plastic
(#10 x 1-1/2")
(Bracket must be securely mounted to sub-floor. Thickness of flooring may require longer screws to anchor the bracket to sub-floor.)
1-1/2"
(3.8 cm)
28 _
(71.1 cm)
depth
with
handle
30" (76.2 cm) j Jar I
rear vent width
Slide-in Range
36-1/8"
(91.8 cm)
cooktop
height
iMPORTANT: Rear vent must not
be obstructed for proper ventilation on
aJlsJidedn models.
See Step 7, Panel D.
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280); or when such
standard is not appJicabJe,the Standard for
Manufactured Homes installations (Manufactured Home Sites, Communities and Setups), ANSI
A225.1/NFPA 501A*, or with local codes.
In Canada, the installation of this range must conform
with the current standards CAN/CSA-Z240 -- latest edition**, or with local codes.
When this range is installed in a mobile home, it must
be secured to the floor during transit. Any method of
securing the range is adequate as long as it conforms to the standards listed above.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch Park Quincy, Massachusetts 02269
**CSA International
8501 East Pleasant'Valley Road Cleveland, Ohio 44131-5575
PaneJ B
(2.54 cm) spacer
(71.1 cm) ...
depth "_
with
handle
30"
(76.2 cm)
28"
width
The floor anti-tip bracket must
be instaJJed.To instaJJthe anti-tip bracket shipped with the range,
see PaneJ D and the anti-tip
bracket template.
Loading...
+ 4 hidden pages