Déplacement de la cuisinière .....................................................20
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
ve for local electrical inspector's use.
W10694065B
RANGE SAFETY
Your safety and the safety of others are very important.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
TANT :
ver pour consultation par l'inspecteur local des installations électriques
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
Range Foot
Anti-Tip
Bracket
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation instructions.
Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed and engaged.
Failure to follow these instructions can result in death or serious burns to children and adults.
To verify the anti-tip bracket is installed and engaged:
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor or wall.
• Slide range back so rear range foot is under anti-tip bracket.
• See installation instructions for details.
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools Needed
■ Tape measure
■ Level
■ Phillips screwdriver
■ Flat-blade screwdriver
Parts supplied
Check that all parts are included.
■ 3 - 10-32 hex nuts (attached to terminal block)
■ 3 - Terminal lugs
■ Oven racks
■ 2 - #12 x 1
■ Anti-tip bracket (taped inside upper oven with package
5
/8" screws (for mounting anti-tip bracket)
containing literature)
Anti-tip bracket must be securely mounted to back wall or
floor. Thickness of floor may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
If using a power supply cord:
■ A UL Listed power supply cord kit marked for use with
ranges. The cord should be rated at 250 volts minimum,
40 amps or 50 amps that is marked for use with nominal
13/8" (3.5 cm) diameter connection opening and must end
in ring terminals or open-end spade terminals with
upturned ends.
■ A UL Listed strain relief.
Check local codes. Check existing electrical supply. See the
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
■ Wrench or pliers
3
■
/8" nut driver
■ Hand or electric drill
1
■
/8" (3.2 mm) drill bit
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■ It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the control panel.
■ To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
■ The floor anti-tip bracket must be installed. To install the
antitip bracket shipped with the range, see the “Install AntiTip Bracket” section.
■ Grounded electrical supply is required. See the “Electrical
Requirements” section.
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate or sustain other damage. This
range has been designed in accordance with the requirements
of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
Mobile home installations require:
■ When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
■ Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to
be revised. See the “Electrical Connection” section.
2
Product Dimensions
B**
C*
K
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (63.5 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible
walls with zero clearance.
A*
D
E***
/16" ± 1/16" (76.0 cm ±
A. 353/4" ± 1/8" (90.8 cm ±
0.3 cm) cooktop height
(minimum) with leveling legs
screwed all the way in*
B. Model/serial/rating plates
(located behind the control
panel)**
F
C. 473/8" ± 1/8" (120.3 cm
± 0.3 cm) overall height
(minimum) with leveling legs
screwed all the way in*
1
D. 28
/2" ± 1/4" (72.4 cm ±
0.6 cm) depth with handle
1
E. 26
/8" ± 1/8" (66.4 cm ±
0.3 cm)***
15
F. 29
0.2 cm) width
* Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
** Model/serial/rating plates may be rotated up from behind the
control panel for viewing from the front of the range.
*** Excludes handle. Dimension given is from wall to front of
oven door and will vary based on electric outlet receptacle
installation.
B
C
D
A
E
J
I
A. 18" (45.7 cm) upper
cabinet to countertop
B. 13" (33.0 cm) upper
cabinet depth
C. 30" (76.2 cm) min.
opening width.
D. For minimum clearance
to the top of the cooktop,
see NOTE.
E. U.S.A.: 30" (76.2 cm) min.
opening width
Canada: 31" (78.7 cm)
min. opening width
G
H
F. Cabinet door or hinge
should not extend into
cutout*
G. 1
right side cabinet
H. 2" (5.1 cm) min. from floor
I. 7" (17.8 cm) height
J. 8" (20.3 cm) width
K. 3
floor
F
1
/2" (3.8 cm) min. from
1
/2" (8.9 cm) min. from
Proper positioning of outlet shown above.
* Nothing located in shaded areas can extend more than
11/2" (3.8 cm) from wall or range will not slide all the way back.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than 1/4" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or
metal cabinet.
3
Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■ Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial rating plate.
The model/serial rating plate is located behind the control
panel. Refer to the figures in “Product Dimensions” in the
“Location Requirements” section.
■ This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, UL Listed, 40- or
50- amp power supply cord (pigtail) (see the following Range
Rating chart). If local codes do not permit ground through
the neutral, use a 4-wire power supply cord rated at 250
volts, 40- or 50-amps and investigated for use with ranges.
Range Rating*Specified Rating of
120/240 Volts120/208 VoltsAmps
8.8 - 16.5 KW
16.6 - 22.5 KW
* The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
** If connecting to a 50-amp circuit, use a 50-amp rated cord
with kit. For 50-amp rated cord kits, use kits that specify use
with a nominal 13/8" (34.9 mm) diameter connection opening.
■ A circuit breaker is recommended.
■ The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic
sheathed, copper or aluminum cable. See the “Electrical
Connection - U.S.A. Only” section.
■ Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
■ A UL Listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
■ Wire sizes and connections must conform with the rating of
the range.
■ The wiring diagram is located on the Tech Sheet.
■ The Tech Sheet is located on the back of the range inside a
clear plastic bag.
1 Batterymarch Park
Quincy, MA 02169-7471
Power Supply Cord Kit
and Circuit Protection
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
neutral by a link. The ground must be revised so the green
ground wire of the 4-wire power supply cord is connected to the
cabinet. See the “Electrical Connection - U.S.A. Only” section.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL Listed, 4-wire, 250-volt, 40- or 50-amp, range
power supply cord (pigtail) must be used. This cord contains
4 copper conductors with ring terminals or open-end spade
terminals with upturned ends, terminating in a NEMA Type
14-50P plug on the supply end.
The fourth (grounding) conductor must be identified by a green
or green/yellow cover and the neutral conductor by a white
cover. Cord should be Type SRD or SRDT with a UL Listed strain
relief and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord
are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-10 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL Listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord
contains 3 copper conductors with ring terminals or open-end
spade terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance
end must be provided at the point the power supply cord enters
the appliance. This uses a 3-wire receptacle of NEMA Type
10-50R.