INSTALLATIONINSTRUCTIONS
ANDUSE ANDCARE GUIDE
ArchitectTMSeriesOutdoorBuilt-lnSideBurner
IMPORTANT:
Read and save these instructions.
IMPORTANT:
Installer: Leave Installation Instructions with the consumer.
Consumer: Keep Installation Instructions for future
reference.
Save Installation Instructions for local electrical inspector's
use.
Write the model and serial numbers in space provided below before
installing or using outdoor Side Burner. The numbers are stamped on
the identification label, located on bottom flange of the control panel.
they are also located on the model/serial number plate, located on the
side panel.
Model #
Serial #
Model KSBN220SSS
Quick Reference
Table of Contents:
Pages
2 Outdoor Built-In Side Burner Safety
4 Installation Requirements
4 Tools and Parts
4 Location Requirements
4 Product Dimensions
5 Enclosure Cutout Dimensions
5 Gas Supply Requirements
6 ArchitecVMSeries Built-InOutdoor Side
Burners
6 L.P. Gas Conversion
6 Outdoor Side Burner Installation
7 Check and Adjust the Burners
8 Outdoor Side Burner Use
8 Using the Outdoor Side Burner
9 Cleaning
10 Warranty
11 Requesting Assistance or Service
I_itchen_kid _
FORTHE WAY IT'S MADE _'
Part No. 9763758
OUTDOOR BUILT-INSIDEBURNER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
followYoucaninstructions,be killed or seriously injured if you don't immediately
Youinstructions,can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
FOR YOUR SAFETY
If you smell gas:
* Shut off gas to the appliance.
FOR YOUR SAFETY
* Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliances.
- Extinguish any open flame.
- Open lid.
- If odor continues, immediately call your
- An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
gas supplier or your fire department.
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
. Do not try to light any appliance.
. Do not touch any electrical switch; do not use any phone in your building.
. Clear the room, building, or area of all occupants.
. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
. If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
IMPORTANTSAFETY INSTRUCTIONS
1. Do not install portable or built-in grills in or on a recreational
vehicle, portable trailer, boat or in any other moving installa-
tion.
2. Always maintain minimum clearances from combustible
construction, see "Location Requirements" section.
3. The outdoor cooking gas appliance shall not be located under
overhead unprotected combustible construction.
4. This outdoor cooking gas appliance shall be used only
outdoors and shall not be used in a building, garage, or any
other enclosed area.
5. Keep any electrical supply cord and fuel supply hose away
from any heated surfaces.
6. Keep outdoor cooking and appliance area clear and free from
combustible materials, gasoline and other flammable vapors
and liquids.
7. Do not obstruct the flow of combustion and ventilation air.
Keep the ventilation openings of the cylinder enclosure free
and clear from debris.
8. Inspect the gas cylinder supply hose before each use of the
grill. If the hose shows excessive abrasion or wear, or is cut, it
MUST be replaced before using the grill. Contact your dealer
and use only replacement hoses specified for use with the
grill. If removal of an access plate(s) or opening of a door(s) is
required for this inspection, instructions shall be provided on
how to gain access for the inspection.
9. Visually check the burner flames. They should be blue. Slight
yellow tipping is normal for L.R gas.
10. Check and clean burner/venturi tube for insects and insect
nest. A clogged tube can lead to fire under the grill.
11. The L.R gas supply cylinder to be used must be:
,,constructed and marked in accordance with the
Specification for L.R Gas Cylinders of the U.S. Department
of Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339, Cylinders, Spheres, and Tubes for
Transportation of Dangerous Goods; and Commission.
,,provided with a listed overfilling prevention device.
,,provided with a cylinder connection device compatible with
the connection for outdoor grill appliances.
12. Always check connections for leaks each time you connect
and disconnect the L.R gas supply cylinder. See "Installation
Instructions" section.
13. When the outdoor cooking gas appliance is not in use, the
gas must be turned off at the supply cylinder.
14. Storage of an outdoor gas grill appliance indoors is permis-
sible only if the cylinder is disconnected and removed from the
outdoor gas grill.
15. Cylinders must be stored outdoors and out of the reach of
children and must not be stored in a building, garage, or any
other enclosed area.
16. The pressure regulator and hose assembly supplied with the
outdoor gas grill must be used. A replacement pressure
regulator and hose assembly specific to your model is avail-
able from your outdoor grill dealer.
17. The cylinder supply system must be arranged for proper vapor
withdrawal.
18. Gas cylinder must include a collar to protect the cylinder valve.
Save These Instructions
If the following information is not followed exactly, a fire
causing death or serious injury may occur.
,, Do not store a spare LP-gas cylinder under or near this side
burner.
,, Never fill the cylinder beyond 80 percent full.
IMPORTANT:
This side burner is manufactured for outdoor use only.
For side burners that are to be used at elevations above 2000 feet,
orifice conversion is required. See "Gas Supply Requirements"
section.
It is the responsibility of the installer to comply with the minimum
installation clearances specified on the model/serial rating plate.
The model/serial rating plate can be found on the side panel.
Copies of the standards listed may be
obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
The California Safe Drinking Water and Toxic Enforcement
Act requires the Governor of California to publish a list of
substances known to the State of California to cause cancer,
birth defects, or other reproductive harm, and requires
businesses to warn of potential exposure to such substances.
WARNING: This product contains a chemical known to the
State of California to cause cancer, birth defects, or other
reproductive harm.
This appliance can cause Iowqevel exposure to some of the
substances listed, including benzene, crystalline silica, carbon
monoxide, toluene, and soot.
In the State of Massachusetts, the following installation
instructions apply:
,, Installations and repairs must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified or licensed
by the State of Massachusetts.
,, If using a ball valve, it shall be a T-handle type.
,,A flexible gas connector, when used, must not exceed 3 feet.
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
,, Level
,, Small flat-blade screwdriver
,, Flat-blade screwdriver
,, Phillips screwdriver
,, Tape measure or ruler
,, Slip-joint pliers
,, Pipe wrench
Parts needed
, Gas line shutoff valve
, 1/2" male pipe thread nipple for connection to pressure
regulator
* L.P. gas-resistant pipe-joint compound
, CSA design-certified outdoor flexible stainless steel appliance
connector
[4-5 ft. (1.2-1.5 m)] or rigid gas supply line as needed
,, Noncorrosive leak detection solution
Parts supplied
,, Convertible regulator set for 4" W.C. natural gas
Fire Hazard
Do not use side burner near combustible materials.
Do not store combustible materials near side burner.
Doing so can result in death or fire.
Select a location that provides minimum exposure to wind
and traffic paths. The location should be away from strong
draft areas.
Do not obstruct flow of combustion and ventilation air.
Fire Hazard
Do not install this side burner on or near combustible
materials.
Doing so can result in death or fire.
il
Explosion Hazard
Do not store fuel tank in a garage or indoors.
Do not store side burner with fuel tank in a garage or
indoors,
Failure to follow these instructions can result in death,
explosion, or fire.
Clearance to combustible construction for built-in outdoor side
burners:
,,A minimum of 12" (30.5 cm) must be maintained between the
sides and back and any combustible construction.
,,A 12" (30.5 cm) minimum clearance must also be maintained
below the cooking surface and any combustible construction.
(30.5cm)
p 12"
T
13-1/4"
(88.7cm)
2_ @@
1/2"
male NPT
3-1/2"