KitchenAid KICU265H, 423, KICU285H User Manual 2

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
KICU265H KICU285H
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply. Use copper wire only. A time­delay fuse or circuit breaker and separate circuit is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 4360369 Rev. C
10-15-02
®
8’ (2.4 m) min. ­9’ (2.7 m) max. ceiling to floor
support structure
24" (61 cm) min. bottom of canopy to cooking surface
canopy
lower chimney
upper chimney
36" (91.4 cm) base cabinet height
3-1/4" x 10" (8.3 cm x 25 cm) through the roof
roof cap
Horizontal wall venting
3-1/4" x 10" (8.3 cm x 25 cm) through the wall
wall cap
Vertical roof venting
The vent system length should not exceed the lengths shown in the chart below.
Vent size Maximum length
3-1/4" x 10" 35 ft. (10.7 m)
(8.3 cm x 25 cm)
7" (17.8 cm) round 40 ft. (12.2 m)
8" (20.3 cm) round 50 ft. (15.2 m)
9" (22.9 cm) round 60 ft. (18.3 m)
Vent Piece 3-1/4" x 10" (8.3 cm x 25 cm) 7" (17.8 cm), 8" (20.3 cm)
Rectangular or 9" (22.9 cm) Round
45° elbow 7.0 feet 2.5 feet
(2.1 m) (0.8 cm)
90° elbow 5.0 feet 5.0 feet
(1.5 m) (1.5 m)
90° flat elbow 12.0 feet
(3.7 m)
transition to round 5.0 feet
(1.5 m)
wall cap 0.0 feet
(0.0 m)
3-1/4" x 10” (8.3 cm x 25 cm) elbow
wall cap
Maximum length = 35 ft. (10.7 m)
1 — 90° elbow = 5 ft. (1.5 m) 8 ft. (2.4 m) straight = 8 ft. (2.4 m) 1 — wall cap = 0 ft. (0 m)
Length of 3-1/4" x 10" (8.3 cm x 25 cm) system = 13 ft. (4 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
v
ent system
To calculate the length of the system you need, add the equivalent feet for each vent piece used in the system.
Note: Flexible vent is Not recommended.
If it is used, each foot of flexible vent used is equivalent to two feet (61 cm) of straight metal vent when calculating the vent system length. (Example: A flexible elbow equals two standard elbows.)
36" hood 35-3/8" (89.9 cm) or 48" hood 47-1/4" (120 cm) overall width
23-5/8" (60 cm) overall depth
24-5/8" (62.5 cm) min. ­34-3/4" (88.3 cm) max. overall chimney height
23-5/8" (60 cm) lower chimney height
1" (2.5 cm) min. ­11-1/8" (23.8 cm) max. upper chimney height
10-1/4" (26 cm) canopy height
7 1/16"
(17.9 cm)
10 7/8"
(27.6 cm)
Note: 3-1/4" x 10" (8.3 cm x 25 cm) rectangular vent must be used inside chimney cover. Round vent will not fit inside chimney cover.
Note: 3-1/4" x 10" (8.3 cm x 25 cm) rectangular vent must be used inside chimney cover. Round vent will not fit inside chimney cover.