30" Freestanding and Slide-In Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
KGRS807S
KGRS807X
KGSK901S
KGSS907S
KGSS907X
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10526089A
2/13/13
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with Natural
gas or, after proper conversion, for use with LP gas.
●
This range is factory set for use with Natural gas. See the “Gas
Conversions” section. The model/serial rating plate located behind the
storage drawer on the right-hand side oven frame has information on
the types of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas
without consulting the serving gas supplier. See the “Gas Conversions”
section.
Gas Supply Line
●
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient
gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON®†tape.
Flexible metal appliance connector:
●
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
●
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
●
Do not kink or damage the flexible metal tubing when moving the
range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to
obtain an in-line connection to the range. The rigid pipe must be level
with the range connection. All strains must be removed from the
supply and fuel lines so range will be level and in line.
●
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Page 1 of 2
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be
provided.
ELECTRICAL REQUIREMENTS
Freestanding Range
B
A
F**
A. " (14.6 cm)
B. 30" (76.2 cm)
C. 41
" (106 cm) overall height
with leveling legs screwed all
the way in
D. 36" (91.4 cm) cooktop trim
height with leveling legs
screwed all the way in*
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1" (2.5 cm) beyond
24" (61 cm) base cabinet.
C
D*
E. Model/serial number plate
(located on the right-hand
side oven door trim)
" (69.2 cm) max. from
F. 2 7
handle to standoff at back
of range**
B
A. Gas supply line
B. Shutoff valve “open” position
C. To range
A
C
Slide-in Range
A
F
B*
E**
A. 30 " (77.6 cm)
B. 35
" (90.5 cm) height to
underside of cooktop edge
with leveling legs screwed
all the way in*
C. Model/serial number plate
(located on the right-hand
side oven door trim)
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**
D
D 30" (76.2 cm)
on models KGRS807XSP and
KGSS907XSP) from handle to
standoff at back of range**
F. 23" (58.4 cm) countertop
notch to rear of cooktop
INSTALLATION CLEARANCES
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm)
countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop surface.
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1⁄4" (0.64 cm) flame retardant millboard covered with not
less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10526089A
2/13/13
Page 2 of 2
The cooktop sides of the slide-in range fit over
the cutout edge of your countertop.
If you have a square finish (flat) countertop and
the opening width is 30" (76.2 cm), no
countertop preparation is required.
Formed front-edged countertops must have
molded edge shaved flat ³⁄₈" (1.0 cm) from each
front corner of opening.
Tile countertops may need trim cut back ³⁄₈"
(1.0 cm) from each front corner and/or rounded
edge flattened.
If countertop opening width is greater than 30"
(76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on
countertop, first side to side, then front to back.
If countertop is not level, range will not be
level. Range must be level for satisfactory
baking conditions.
SLIDE-IN RANGE COUNTERTOP PREPARATION
30"
(76.2 cm)
"
30
(78.1 cm)
segnaR nI-edilSsegnaR gnidnatseerF
M
N
"
(1.0 cm)
M
A. 18" (45.7 cm) upper cabinet to countertop
B. 13" (33 cm) upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of the cooktop, see NOTE.
E. 30" (76.2 cm) min. opening width
F. This shaded area recommended for installation of rigid gas pipe.
G. 6" (15.2 cm) available area for gas and electric installation
H. Grounded outlet
I. 7" (17.8 cm)
J. 1
¹⁄₂
" (3.8 cm)
¹⁄₂
" (11.4 cm)
K. 4
L. 5" (12.7 cm) min. clearance from both sides of the range to the
side wall or other combustible material.
M. Cabinet door or hinge should not extend into the cutout.
A. 18" (45.7 cm) upper cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of the cooktop, see NOTE.
E. 30" (76.2 cm) min. opening width
F. This shaded area recommended for installation of rigid gas pipe.
G. 6" (15.2 cm) available area for gas and electric installation
H. Grounded outlet
I. 7" (17.8 cm)
J. 1
¹⁄₂
" (3.8 cm)
K. 4
¹⁄₂
" (11.4 cm)
L. 5" (12.7 cm) min. clearance from both sides of the range to the
side wall or other combustible material for models KGSS907 and
KGRS807.
2" (5.1 cm) min. clearance for model KGSK901
M. 22
¹⁵⁄₁₆
" (58.3 cm) opening depth
N. ¾" (1.9 cm) radius both corners
O. Cabinet door or hinge should not extend into the cutout.
O