Kitchenaid KGCU462VSS, KGCU467VSS, KGCU407VSS, KGCU463VSS, KGCU482VSS Dimension Guide

...
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
KGCU407V KGCU462V KGCU463V KGCU467V
KGCU482V KGCU483V KGCU484V
Type of Gas Natural Gas:
This cooktop is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.
This cooktop is factory-set for use with Natural gas. To convert to LP gas, see the Gas Conversion instructions provided in the package containing literature. The model/ serial rating plate located on the left underside of the cooktop burner base has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the cooktop from the
gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. To convert to LP gas, use the LP gas conversion kit provided with the cooktop and see the “Gas Conversions” section.
Electrical:
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this cooktop be provided.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10271686D
08/26/09
Commercial Style Gas Cooktop
®
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.
It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the underside of the cooktop burner base.
It is recommended that a 600 CFM or larger vent hood be installed above the cooktop.
It is not recommended that a microwave hood combination be mounted above the cooktop.
The cooktop should be installed in a location away from strong draft areas, such as windows, doors and strong heating vents or fans.
All openings in the wall or floor where cooktop is to be installed must be sealed.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.
Page 1 of 2
C
B
A
A. 30" (76.2 cm) cooktop: 29
36" (90.4 cm) cooktop: 35 48" (121.9 cm) cooktop: 47
B. 36" (91.4 cm) long 3 prong grounding-type
power supply cord
⁵⁄₈
" (75.1 cm)
⁵⁄₈
" (90.4 cm)
⁵⁄₈
" (120.8 cm)
D
E
C. Model/serial rating plate (located on the
underside of the cooktop burner base)
D. Island trim or optional backguard
E. 27¾" (70.5 cm)
A
B
G
E
Side View of Cooktop
F
A. 27¾" (70.5 cm) B. 1¼" (3.2 cm)
⁷⁄₁₆
" (18.8 cm)
C. 7 D. Gas inlet is located 1
the cooktop burner base and 4 from left-hand side of the cooktop burner base.
⁷⁄₈
" (4.8 cm) from the back of
⁷⁄₈
" (12.4 cm) in
C
D
E. 22" (55.9 cm)
⁵⁄₈
" (9.2 cm)
F. 3
G. 1" (2.6 cm)
Commercial Style Gas Cooktop
CABINET REQUIREMENTS
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10271686D
08/26/09
Page 2 of 2
®
Gas and Electric Connection Locations
A
O
E
D
N
A. Grounded 3-prong outlet should be located on
left-hand side of the cutout 16" (40.6 cm) max. from enclosure sidewall
B. 10" (25.4 cm) min. clearance from countertop to
top of the outlet C. 14" (35.6 cm) countertop to the gas supply line D. Gas supply line should be located in this area on
rear or side walls, or the supply line can come up
B
C
through the floor.
NOTE: Solid side and bottom of cutout enclosure not shown.
D
A. See chart.
C
P
F
L
J
I
K
D
E
C
G
A**
B min.*
H
L
M
B. See chart.
C. See chart.
D. See chart.
E. See chart.
F. 18" (45.7 cm) min. clearance upper
cabinet to countertop
¾
" (1.9 cm) back of cabinet cutout to gas
G.
opening cutout
6⁷⁄₈
H.
" (16.1 cm) gas opening cutout depth
I.
12½
" (31.7 cm) gas opening cutout width
22¼
J. " (56.5 cm) cabinet cutout depth
K. 2" (5.1 cm) cabinet side to gas cutout
L. 6" (15.2 cm) min. distance on both sides of the
cooktop to the side wall or other combustible material above cooking surface
M. 24" (61.0 cm) cabinet depth
7¼
N. " (18.4 cm) cabinet depth to countertop O. Notch to be equal on both sides
P. 13" (33.0 cm) upper cabinet depth
Size Model A**
Cooktop Cutout to Back Wall
30" (76.2 cm) KGCU407 30" (76.2 cm) ) 30" (76.2 cm) or
36" (91.4 cm) KGCU462
KGCU463 KGCU467
48" (121.9 cm) KGCU482
KGCU483 KGCU484
1¾" (4.4 cm)**
1½" (3.8 cm)** 1¾" (4.4 cm) 1¾" (4.4 cm)
1½" (3.8 cm)** 1¾" (4.4 cm)** 1½" (3.8 cm)**
B* Cooktop to
Cabinet
42" (106.7 cm)
42" (106.7 cm)
*NOTES: Dimension “B” can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet is covered by not less than
0.25" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. If installing a range hood above the cooktop, follow the range hood instructions for dimensional clearances above the cooktop
surface.
**NOTE: If backwall is constructed of a combustible material and a backguard is not installed, a minimum clearance of dimension A +
6" (15.2 cm) is required for
48" (121.9 cm) cooktops and cooktops with a grill.
C Optional
Backguard
D Cabinet and
Countertop
E Countertop Only
Opening
30" (76.2 cm) 29¼" (74.3 cm)
29 (75.9 cm) for
⁷⁄₈"
zero clearance
36" (91.4 cm)
35¼" (89.5 cm)
36" (91.4 cm) or
⁷⁄₈"
35 (91.1 cm) for zero clearance
48" (121.9 cm)
47¼" (120.0 cm) 48" (121.9 cm) or
⁷⁄₈"
47 (121.6 cm) for zero clearance