Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire.
Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
Réglage de la taille des flammes ...............................................19
Achever le réglage des brûleurs.................................................20
COOKTOP SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
•
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
•
If you cannot reach your gas supplier, call the fire department.
– Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
■
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
■
If using a ball valve, it shall be a T-handle type.
■
A flexible gas connector, when used, must not exceed 3 feet.
2
Tools and Parts
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is
not proper and complete until the
operation of the converted appliance is
checked as specified in the
manufacturer's instructions supplied with
this kit.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A
B
C
D
Gather the required tools and parts necessary for correct LP gas
conversion.
For models KCGS550ESS, KCGS556ESS, KCGS950ESS and
KCGS956ESS use the following parts:
■ LP orifice package (W10676662)
■ Conversion instructions (W10597146A)
For all other models use the following parts:
■ LP orifice package (W10676661)
■ Conversion instructions (W10597146A)
High Altitude Conversion
®†
adapter
To convert the cooktop for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
For models KCGS550ESS, KCGS556ESS, KCGS950ESS and
KCGS956ESS use the following parts:
■ Part Number W10679116 - LP high altitude
■ Part Number W10679118 - Natural gas high altitude
For all other models use the following parts:
■ Part Number W10679114 - LP high altitude
■ Part Number W10679113 - Natural gas high altitude
To order, see the “Assistance or Service” section of the User Guide.
IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer. Before proceeding with
conversion, shut off the gas supply to the cooktop prior to
disconnecting the electrical power.
Convert from Natural Gas to LP Gas
1. Turn manual shutoff valve to the closed position.
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas flow
3. Determine the type of regulator you have:
Style 1: The cap has a slot and “NAT” printed on it.
Remove access cap by using a flat-blade screwdriver or coin,
turning the access cap counterclockwise.
3
The gas pressure regulator has 2 settings that are stamped
A
B
CDE
A
A
on either side of the cap. Turn the cap and reinstall into
regulator with the stamp “LP” visible from the outside of the
regulator.
Style 2: The cap does not have a slot and requires a wrench
to be removed.
Remove the access cap by using a wrench, turning the
access cap counterclockwise.
Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the “NAT” or “LP” position. Turn over the spring
retainer so the “LP” is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
LP Gas Orifice Spud Chart for Kit W10676661
Burner
Rating
5,000 BTUGreen660.66 mm
7,000 BTUWhite750.75 mm
8,000 BTUOrange790.79 mm
11,000 BTURed970.97 mm
13,000 BTUYellow1081.08 mm
16,000 BTUPink1151.15 mm
12,000 BTU
Inner
Outer
ColorStamp (A) Size
Brown
Brown
85
48
0.85 mm
0.48 mm
Burner Models for Kit W10676661
Model No.Left
WCG51US0D
MGC7430D
ICS500DS00
WCG75US0D
MGC9530D66Green
WCG97US0D
KCGS350E
ICS655DS00
WCG51US6D
MGC7536D75White75White
WCG97US6D
MGC9536D
KCGS356E
Front
66
Green
75
White79Orange85Brown48Brown66Green75White
75
White75White85Brown48Brown66Green97Red
Left
Rear
108
Ye ll o w
115
Pink
Center
Inner
Ye ll o w
Center
Outer
N/AN/A97
N/AN/A97
108
N/A66
A. Size stamp
Right
Rear
Red75White
Red75White
Green97Red
Right
Front
A. Access cap
B. Gasket
C. Gas pressure regulator
D. LP position
E. NAT position
4. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Gas Supply Pressure Testing
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
5. If the burner grates are installed, remove them.
Use the following charts to match the correct gas orifice spud
with the burner location and model being converted.
LP Gas Orifice Spud Chart for Kit W10676662
Burner
Rating
5,000 BTU
6,000 BTUGreen700.70 mm
9,100 BTUBlack890.89 mm
11,000 BTUOrange970.97 mm
13,000 BTU
Inner
Outer
14,000 BTU
Inner
Outer
16,000 BTU
Inner
Outer
9,000 BTU
Inner
Outer
ColorStamp (A) Size
White
Blue
Brown
Blue
Ye ll o w
Blue
Red
Pink
Pink
660.66 mm
45
97
45
101
45
105
40
80
0.45 mm
0.97 mm
0.45 mm
1.01 mm
0.45 mm
1.05 mm
0.40 mm
0.80 mm
A. Size stamp
4
Burner Models for Kit W10676662
B
D
C
E
A
D
A
B
C
A
B
C
D
E
D
A
B
C
A
A
B
A
B
Model No.Left
KCGS550E
KCGS556E
KCGS950ES
KCGS956ES
Front
Black66White45Blue97Brown70Green89Black
Black66white45Blue
Black66White45Blue97Brown70Green40Pink80Pink
Orange66White45Blue
89
89
89
97
Left
Rear
Center
Inner
Burner locations
Center
Outer
Ye ll ow70Green89Black
Right
101
105
Red70Green40Pink80Pink
Rear
Right
Front
Inner
Right
Front
Outer
N/A
N/A
Torch Burner
A. Inner burner cap
B. Inner burner base
C. Outer burner base
D. Burner support
E. Gas tube opening
7. To Convert Standard Burner:
■ Use 7.0 mm wrench to loosen and remove the orifice
spud (A).
■ Set gas orifice spud aside.
■ Replace with correct LP gas orifice spud. See LP gas
orifice spud charts.
A. Left front
B. Left rear
C. Center
D. Right rear
E. Right front
6. Remove all burner caps and burner bases (see the User
Guide for burner reference).
To remove the burner base for the Dual Flame and Dual Tier
Ultra Torch burners use a Torx
Dual Tier Ultra Burner
A. Inner burner cap
B. Outer burner cap
C. Gas tube opening
D. Burner base
®
T10 driver to remove the screw.
Standard and Dual Flame
A. Burner cap
B. Igniter electrode
C. Burner base
D. Gas tube opening
A. Orifice spud
8. To Convert Dual Tier Ultra and Dual Flame Burners:
■ Use 7.0 mm wrench to loosen and remove the inner
orifice spud (A) and the outer orifice spud (B).
■ Set gas orifice spuds aside.
■ Replace with correct LP gas orifice spuds. See the LP gas
orifice spud charts.
Dual Tier Ultra Burner
A. Inner orifice spud
B. Outer orifice spud
Dual Flame Burners
A. Inner orifice spud
B. Outer orifice spud
5
9. To C onvert To r ch Burner
A
B
C
B
C
A
A
B
C
A
B
C
D
NAT
■
Remove the spring that is shown in the following
illustration (C).
■ Use 7.0 mm wrench to loosen and remove the inner
orifice spud (A) and the outer orifice spud (B).
■ Set gas orifice spuds aside.
■ Replace with correct LP gas orifice spud. See the LP gas
orifice spud charts.
■ Return the spring to its original location.
A. Inner orifice spud
B. Outer orifice spud
C. Spring
IMPORTANT: Place Natural gas orifice spuds in plastic parts
bag for future use and keep with package containing
literature.
10. Replace sheet of insulation.
11. Replace burner bases and burner caps.
The igniter electrode is ceramic and could break during
conversion. Be sure that the electrode comes through the
hole in the burner smoothly while you are replacing the burner
base.
Convert from LP Gas to Natural Gas
1. Turn manual shutoff valve to the closed position.
A. To cooktop
B. Shutoff valve (closed position)
C.Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas flow
A. Burner cap
B. Electrode
C. Burner base
12. Open shutoff valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
13. Plug in cooktop or reconnect power.
REMEMBER: Once you have completed converting all of the
cooktop burners, test the cooktop for leaks by brushing on
an approved noncorrosive leak-detection solution. If bubbles
appear, a leak is indicated. Correct any leaks found.
14. To adjust single and dual valves, see the “Flame Height
Adjustment” section.
3. Determine the type of regulator you have:
Style 1: The cap has a slot and “LP” printed on it.
Remove access cap by using a flat-blade screwdriver or coin,
turning the access cap counterclockwise.
The gas pressure regulator has 2 settings that are stamped
on either side of the cap. Turn the cap and reinstall into
regulator with the stamp “NAT” visible from the outside of the
regulator.
Style 2: The cap does not have a slot and requires a wrench
to be removed.
Remove the access cap by using a wrench, turning the
access cap counterclockwise.