30" (76.2 cm) and 36" (91.4 cm)
Gas Downdraft Cooktop
PRODUCT MODEL NUMBERS
KCGD500G
KCGD506G
GAS REQUIREMENTS
Type of Gas
Natural Gas:
This cooktop is factory set for use with Natural gas. If
converting to LP gas, see the “LP Gas Conversion” instructions
provided in the package containing literature. The model/serial/
rating plate located on bottom of the cooktop has information
on the types of gas that can be used. If the types of gas listed
do not include the type of gas available, check with the local
gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial/rating plate for use with a different
gas without consulting the serving gas supplier. See the “Gas
Conversion” instructions provided in the package containing
literature.
Gas Supply Line
■ Provide a gas supply line of
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds
that resist the action of LP gas must be used. Do not use
TEFLON®† tape. With LP gas, piping or tubing size should
be 1⁄2" minimum. Usually, LP gas suppliers determine the
size and materials used in the system.
PRODUCT DIMENSIONS
30" (76.2 cm) Cooktop 36" (91.4 cm) Cooktop
3
⁄4" (1.9 cm) rigid pipe to the
Flexible metal appliance connector:
■ If local codes permit, use a
steel tubing gas connector, designed by CSA to connect
the cooktop to the rigid gas supply line.
1
■ A
⁄2" male pipe thread is needed for connection to the
female pipe threads of the inlet to the cooktop pressure
regulator.
■ Do not kink or damage the flexible metal tubing when
moving the cooktop.
■ Must include a shut-off valve:
The supply line must be equipped with a manual shut-off
valve. This valve should be located in the same room. It
must be accessible without removing the cooktop, and it
should be in a location that allows ease of opening and
closing. Do not block access to shut-off valve. The valve is
for turning on or shutting off gas to the cooktop.
A. Gas supply line
B. Shut-off valve open position
C. To cooktop
1
⁄2" or 3⁄4" I.D. flexible stainless
B
A
C
A
B
A. 211/2" (54.6 cm)
B. 1911/16" (50.0 cm)
C. Model/serial/rating
plate location
A
B
D
E
H
A 30" (76.2 cm)
B. 4" (10.2 cm)
C. 619/32" (16.8 cm)
D. 187/16" (46.8 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
E. 111/16" (4.3 cm) recommended
minimum cabinet to motor clearance
F. 121/2" (31.8 cm)
G. 14" (35.6 cm)
H. 281/4" (71.4 cm)
C
C
GF
A
A. 211/2" (54.6 cm)
B. 1911/16" (50.0 cm)
C. Model/serial/rating
plate location
A
B
D
E
A. 36" (91.4 cm)
B. 4" (10.2 cm)
C. 619/32" (16.8 cm)
D. 187/16" (46.8 cm)
Dimensions are for planning purposes only. For complete details, see
Installation Instructions packed with product. Specifications subject to
change without notice.
E. 103/8" (26.4 cm) recommended
F. 121/2" (31.8 cm)
G. 13" (33.0 cm)
H. 343/8" (87.3 cm)
H
minimum cabinet to motor clearance
C
GF
B
C
Page 1 of 2
Ref. W10848427B
01/2017
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It
is recommended that a separate circuit serving only this cooktop be provided.
CABINET DIMENSIONS
A
D
C
N
B
L
E
F
G
H
M
I
K
J
K
M
A. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61.0 cm]
minimum clearance if bottom of wood or metal cabinet is covered by
not less than 1/4" [0.6 cm] flame-retardant millboard covered with not
less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel,
0.024" [0.06 cm] aluminum, or 0.020" [0.05 cm] copper)
D. 13" (33.0 cm) recommended upper cabinet depth
E. 21/8" (5.4 cm)
F. 1915/16" (50.6 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet: 12" (30.5 cm) minimum from bottom of
countertop
I. Junction box or outlet: 10" (25.4 cm) from right-hand side of cabinet
J. 285/8" (72.7 cm) on 30" (76.2 cm) models
343/4" (88.3 cm) on 36" (91.4 cm) models
K. 6" (15.2 cm) minimum distance to nearest left and right side
combustible surface above cooktop
L. 2" (5.1 cm) minimum clearance between back wall and countertop
cutout
M. Gas line opening - Wall: anywhere 6" (15.2 cm) below underside of
countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is
recommended.
N. 25" (63.5 cm) depth of countertop
NOTE: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the
cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
■ A minimum side clearance of 6" (15.2 cm) is recommended between side of cooktop and side wall for maximum ventilation
performance.
CUTOUT DIMENSIONS
A
C
H
I
J
G
B
A. 285/8" (72.7 cm) maximum on 30" (76.2 cm) models
343/4" (88.3 cm) maximum on 36" (91.4 cm) models
B. 1915/16" (50.6 cm) maximum on both 30" (76.2 cm) and 36" (91.4 cm)
D
E
F
models
C. 81/2" (21.6 cm) on 30" (76.2 cm) models
171/2" (44.4 cm) on 36" (91.4 cm) models
D. 53/4" (14.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models
E. 21/8" (5.4 cm) minimum space to front edge of cooktop
F. Floor exhaust option
G. 61/8" (15.6 cm) for 6" vent system
H. 81/2" (21.6 cm) on 30" (76.2 cm) models
171/2" (44.4 cm) on 36" (91.4 cm) models
I. 16" (40.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models
J. Wall exhaust option
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see
Installation Instructions packed with product. Specifications subject to
change without notice.
Page 2 of 2