KitchenAid 9763393A User Manual

30" (76.2 CM) AND 36" (91.4 CM)
SLIDE-OUT VENT RANGE HOOD
Installation Instructions and Use &Care Guide
HOTTE D'ASPIRATION AVEC MODULE DE
COMMANDE EXTRACTIBLE DE 30" (76,2 CM)
ET 36" (91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: Installer: Leave installation instructions with the homeowner. Homeowner: Keep installation instructions for future reference.
Save installation instructions for local electrical inspector's use.
IMPORTANT : Installateur : Remettre les instructions d'installation au propriétaire. Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
Conserver les instructions d'installation pour consultation par l'inspecteur local des installations électriques.
9763393A
TABLE OF CONTENTS
TABLE DES MATIÈRES
RANGE HOOD SAFETY .................................................................3
INSTALLATION REQUIREMENTS................................................4
Tools and Parts ............................................................................4
Location Requirements................................................................4
Venting Requirements..................................................................5
Electrical Requirements ...............................................................7
INSTALLATION INSTRUCTIONS..................................................7
Prepare Location.......................................................................... 7
Install Range Hood.....................................................................10
Electrical Connection .................................................................10
Connect the Vent System ..........................................................11
Optional Front Trim Kits.............................................................12
RANGE HOOD USE......................................................................12
KWVU Model Series...................................................................12
GZ and IH Model Series ............................................................13
RANGE HOOD CARE...................................................................13
Cleaning......................................................................................13
Replacing the Bulb.....................................................................13
WIRING DIAGRAMS.....................................................................14
ASSISTANCE OR SERVICE.........................................................16
In the U.S.A. ...............................................................................16
In Canada ...................................................................................16
WARRANTY ..................................................................................17
WARRANTY ..................................................................................18
SÉCURITÉ DE LA HOTTE D’ASPIRATION ................................19
EXIGENCES D’INSTALLATION...................................................21
Outillage et pièces......................................................................21
Exigences d’emplacement.........................................................21
Exigences concernant l’évacuation ...........................................22
Spécifications électriques ..........................................................24
INSTRUCTIONS D'INSTALLATION.............................................25
Préparation de l'emplacement...................................................25
Installation de la hotte de cuisinière...........................................28
Raccordement électrique...........................................................29
Raccordement du circuit d'évacuation......................................29
Ensembles de garniture (option) ................................................30
UTILISATION DE LA HOTTE DE CUISINIÈRE...........................30
Modèles Séries KWVU ..............................................................30
Modèles Séries GZ et IH ............................................................31
ENTRETIEN DE LA HOTTE DE CUISINIÈRE .............................31
Nettoyage ...................................................................................31
Remplacement de la lampe .......................................................31
SCHÉMA DE CÂBLAGE...............................................................32
ASSISTANCE OU SERVICE.........................................................33
GARANTIE ....................................................................................34
GARANTIE.....................................................................................35
2
RANGE HOOD SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
Before servicing or cleaning the unit, switch the power off at
the service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes & standards, including fire-rated construction.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
Ducted systems must always be vented outdoors. CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into spaces within walls ceilings, attics, crawl spaces, or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
Never leave the surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
SMOTHER FLAMES with a close fitting lid, cookie sheet, or
other metal tray, then turn off the gas burner or electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
The fire department is being called. You can fight the fire with your back to an exit.
a
Based on "Kitchen Fire Safety Tips" published by NFPA.
a
SAVE THESE INSTRUCTIONS
3
INSTALLATION REQUIREMENTS
Tools andParts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Too ls ne ed ed
Level
Drill
1¹⁄₄" drill bit
³⁄₈" (8 mm) nut driver or ratchet
Pencil
Pliers
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Phillips screwdriver
Flat-blade screwdriver
Saber or keyhole saw
Vent clamps
Metal snips
Parts supplied
Check that all parts are included.
Literature package
2 screws
Damper
Plastic cover (used for customized front panel)
Hardware package
Parts needed
Tw o ¹⁄₂" (12.7 mm) UL listed or CSA approved conduit
connectors
Wall cap
Metal vent system
Power supply cable
Optional parts needed:
Wood filler strips for cabinets with recessed bottoms. Length
and thickness determined by recess dimensions. See “Prepare Location” section.
Two, 1" x 1" x 5" (25.4 x 25.4 x 127 mm) wood pieces for
cabinet floor. See “Prepare Location” section.
Four, 1¹⁄₄" (31.8 mm) wood screws
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult your cooktop/range manufacturer installation instructions before making any cutouts.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The hood is factory set for vented installations through the
roof or wall. For non-vented installations, Recirculation Kit Part
No. 883140 is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.
4
FRONT OF VENT HOOD
Shelf extends
7" (17.8 cm)
9¹⁄₂"
(24.1 cm)
Product Dimensions
30" (76.2 cm) model: 26" (66.0 cm) 36" (91.4 cm) model: 32" (81.3 cm)
10"
2³⁄₈" (6.0 cm)
8"
(20.3 cm)
(5.1 cm)
(25.4 cm)
2"
30" (76.2 cm) model: 8" (20.3 cm) 36" (91.4 cm) model: 11" (27.9 cm)
4³⁄₈" (11.1 cm)
30" (76.2 cm) model: 13" (33.0 cm) 36" (91.4 cm) model: 16" (40.6 cm)
¹⁄₄"
(6.4 mm)
3¹⁄₄" (8.3 cm)
³⁄₈" (9.5 mm)
1"
(25.4 mm)
Installation Clearances
24" (61 cm) min. 30" (76.2 cm)
suggested max. bottom of cabinet to cooking surface
15" (38.1 cm) min. clearance upper cabinet to countertop
36" (91.4 cm)
base cabinet
height
9¹⁄₈"
(23.2 cm)
11"
(27.9 cm)
30" (76.2 cm) or 36" (91.4 cm) min.
cabinet opening width
13" (33 cm)
cabinet depth
1⁵⁄₈" (41.3 mm)
1¹⁄₄" (31.8 mm)
⁵⁄₈" to 2¹⁄₈" (1.6 cm to 5.4 cm)
(5.1 cm)
1⁷⁄₁₆"
(3.6 cm)
66"(167.6 cm)
min.
72" (182.9 cm)
max. to bottom of cabinet frame
BACK OF
VENT HOOD
30" (76.2 cm) model: 29⁷⁄₈" (75.9 cm) 36" (91.4 cm) model: 35⁷⁄₈" (91.1 cm)
2"
Venting Requirements
Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type wall caps.
Use a metal vent only. A rigid metal vent is recommended. Do
not use plastic or metal foil vent.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than one elbow is used.
Do not install 2 elbows together.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range hood.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
Determine which venting method is best for your application.
Cold weather installations
An additional back draft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent system enters the heated portion of the house.
5
Makeup air
B
B
E
Local building codes may require the use of makeup air systems when using ventilation systems with greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.
Venting Methods
Recommended Standard Fittings
Vent Piece 3¹⁄₄" x 10" (8.3 cm x 25 cm)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 90° elbow
5.0 ft (1.5 m)
The vent system needed for installation is not included. A 3¹⁄₄" x 10" (8.3 cm x 25 cm) rectangular vent system is recommended.
Roof Venting Wall Venting
A
A. 3¹⁄₄" x 10" (8.3 cm x 25 cm)
vent through the roof
B. Roof cap
A
A. 3¹⁄₄" x 10" (8.3 cm x 25 cm)
vent through the wall
B. Wall cap
Calculate Vent System Length
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) flat elbow
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) wall cap
12.0 ft (3.7 m)
0.0 ft (0.0 m)
Recirculating Vent Through the Soffit/Cabinet
This vent hood is factory set for venting through the roof or wall. For recirculating installations, Recirculation Kit Part Number 883140 is available from the dealer or an authorized parts distributor. Damper installation is not required.
A
B
C
D
The recommended vent system length is 3¹⁄₄" x 10" (8.3 cm x 25 cm) vent with maximum length of 26 ft (8 m) for vent system. For the best performance, use no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet (meters) for each of the vent pieces used in the system.
Example vent system
x 10" (8.3 cm x 25 cm)
3¹⁄₄"
90˚ elbow
6 ft (1.8 m)
3 ft
(0.93 m)
Maximum Length = 26 ft (8 m)
1 - 90° elbow = 5 ft (1.5 m) 1 - wall cap = 0 ft (0 m) 9 ft (2.8 m) straight = 9 ft (2.8 m) System length = 14 ft (4.3 m)
Wall cap
A. 3¹⁄₄" x 10" (8.3 cm x 25 cm) vent B. 3
¹⁄₄" x 10" (8.3 cm x 25 cm) elbow
C. Vent cover D. Soffit
D
C
B
A
A. Hood B. Vent system C. Top of cabinet
D. Vent cover
E. Ceiling or soffit
6
Electrical Requirements
For GZ or IH model series:
WARNING: To reduce the risk of fire or electrical shock, do not
use this fan with any solid state speed control device.
For KWVU model series:
This fan is suitable for use with solid state speed controls. IMPORTANT: Observe all governing codes and ordinances. Save
Installation Instructions for electrical inspector’s use. It is the customer’s responsibility to contact a qualified electrical
installer, and to assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
INSTALLATION INSTRUCTIONS
A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is
required.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the range
hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused
disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable.
Wire sizes (copper wire only) and connections must conform
with the rating of the appliance as specified on the model/ serial rating plate.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
A ¹⁄₂" (12.7 mm) UL listed or CSA approved strain relief must
be provided at each end of the power supply cable (at the range hood and at the junction box).
Prepare Location
It is recommended that the vent system be installed before hood is installed.
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for vent fittings.
Preparation
WARNING
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1. If possible, disconnect and slowly move the freestanding
range from the cabinet opening to provide easier access to upper cabinet and rear wall.
2. Determine which venting method to use: roof, wall, or non-
vented.
3. Determine and clearly mark a centerline on the underside of
the cabinet.
A
A. Centerline
4. Measure and mark lines as shown for your size of vent hood.
Use a saber saw or keyhole saw to cut an opening through the underside of the cabinet.
1
¹⁄₂"
(3.8 cm)
9
³⁄₁₆"
(23.3 cm)
30" (76.2 cm) hood - 13 36" (91.4 cm) hood - 16
¹⁄₁₆" ¹⁄₁₆"
(33.2 cm) (40.8 cm)
The finished cutout size will be: 30" (76.2 cm) hood - 9³⁄₁₆" x 26¹⁄₈" (23.3 cm x 66.4 cm) 36" (91.4 cm) hood - 9³⁄₁₆" x 32¹⁄₈" (23.3 cm x 81.6 cm)
7
5. If the cabinet bottom is recessed above a support frame,
wood filler strips need to be installed on the right and left sides of the cutout to provide sides of clearance for the sliding screen. Wood filler strips should be flush with or recessed ¹⁄₁₆"-¹⁄₈" (1.6 mm-3.2 mm) from the bottom of the support frame.
A
Transfer measurement A and B to the cabinet back wall. Measure from the underside of the cabinet or wood filler strips, if used. Mark the cutout as shown. Use a saber saw or keyhole saw to cut a rectangular opening for the vent.
10 ³⁄₄"
(27.3 cm)
A
B
A. Wood filler strips
6. Complete cabinet preparation following the instructions for
your type of installation.
Venting Outside Through the Roof
Measure and mark the lines as shown. Use a saber saw or keyhole saw to cut a rectangular opening for the vent.
(10.2 cm)
Cutout
Centerline
4"
(25.4 mm)
1"
10
³⁄₄"
(27.3 cm)
Centerline
Cutout
Venting Inside Through the Soffit/Cabinet
Measure and mark a rectangular vent opening in the soffit using the method shown for venting through the wall. Measure and mark the same centerline on the soffit above the vent hood area.
A
B
A. Vent cover
B. Centerline
Venting Outside Through the Wall
Assemble the vent that you will use over the vent opening. Do not attach the vent at this time. Measure from the top of the screen housing to the top of the vent opening (A) and back to the bottom of the vent opening (B). Remove the vent.
B
A
8
Use the vent cover from the Recirculation Kit or other vent cover as a template to outline an opening for the vent. Use a saber saw or keyhole saw to cut a rectangular opening for the vent system.
The hood can be vented inside through the top of the cabinet.
(10.2 cm)
Cutout
Centerline
4"
(25.4 mm)
1"
10
³⁄₄"
(27.3 cm)
The Recirculation Kit Part Number 883140 must be used.
7. Install the vent system according to the method needed. Use
caulking to seal the exterior wall or roof opening.
8. Determine wiring knockout. To wire through the top wiring knockout:
Measure and mark a parallel line either 10⁵⁄₈" (27 cm) for the 30" (76.2 cm) hood or 11⁵⁄₈" (29.5 cm) for the 36" (91.4 cm) hood to the right of the centerline on the cabinet ceiling. Mark a point on this line that is 4" (10.2 cm) from the back wall of the cabinet. Drill a 1¹⁄₄" (3.2 cm) diam. hole through the cabinet ceiling.
A
10. Measure the thickness of the cabinet floor, including the filler
strips, if used. If the thickness is less than ⁵⁄₈" (15.9 mm), install wood filler strips that are a minimum length of 5" (12.7 cm) onto the cabinet floor. The mounting bracket adjusts from ⁵⁄₈" (15.9 mm) to 2¹⁄₈" (54 mm) for the wood filler strips.
A
B
A. Wiring cutout
To wire through the rear wiring knockout:
Measure and mark a parallel line 11³⁄₈" (29.8 cm) for the 30" (76.2 cm) hood or 14³⁄₈" (36.5 cm) line for the 36" (91.4 cm) hood to the right of the centerline on the cabinet back wall. Mark a point on this line that is 8¹⁄₄" (21 cm) from the bottom of the cabinet. Drill a 1¹⁄₄" (3.2 cm) diam. hole through the wall.
A
A. Less than B. Wood fillers (thickness as required)
⁵⁄₈
" (15.9 mm)
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
11. Remove the vent hood from the carton. Attach the damper to
the vent opening. If the roof cap or wall cap has a damper, do not attach the damper to the vent hood.
A
A. Wiring cutout
9. Run the wiring through the wall or cabinet according to the national Electrical Code and all local codes and ordinances.
Use caulking to seal around wire opening. NOTE: Do not turn on power until installation is complete.
A. Damper
12. Remove the top or rear knockout from the wiring opening,
depending on which one will be used.
A
A. Wiring knockouts
9
13. Place the vent hood on its back side on a protected surface. a) Slide the screen forward.
b) Pull the tabs to remove the filters. c) Remove the terminal box cover. d) Close the screen. e) Slide the mounting brackets to the top position.
2. Check that the front panel is parallel with the cabinet front
when the screen is pushed in. Slide the screen forward. Tighten the mounting bracket screws so that the vent hood is secured to the cabinet.
A
B
A
A. Terminal box cover
NOTE: For some installations using the recirculating kit, it may be easier to attach the vent system to the hood before lifting the hood into its final position. Seal the connection with clamps.
Install RangeHood
1. Lift the vent hood into its final position and feed the electrical wire through the wiring opening in the range hood. The mounting brackets should overlap the cabinet bottom or wood filler strips. Center the range hood.
A
B
C
D
A. Mounting bracket screw B. Flat-blade screwdriver
3. Align the hood front panel with the cabinet. Slide the screen
forward. Locate the 2 screws on each side and turn them counterclockwise to loosen the screws. Adjust the front of the vent vertically, ³⁄₈" (9.5 mm) up or down, or horizontally, ³⁄₄" (19 mm) front to back, until the front is flush with the cabinet. Tighten the screws. If it is necessary to adjust the given dimensions, lower and add or remove the filler strips or redrill mounting holes.
A
B
A. Phillips screwdriver B. Adjustment screws
Electrical Connection
WARNING
10
A. Mounting bracket B. Cabinet bottom
C. Optional wood filler strip
D. Vent hood
Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Connect the white wire of the power supply cable to the white
wire in the hood with a twist-on connector.
3. Connect the black wire of the power supply cable to the
black wire in the hood with a twist-on connector.
WARNING
Electrical Shock Hazard Electrically ground blower. Connect ground wire to green ground screw in
terminal box. Failure to do so can result in death or electrical shock.
Recirculation installations:
Connect the vent system to the hood vent opening. Seal the connection with clamps.
Install Recirculation Kit (Part Number 883140)
1. Pull out on the range hood to expose the filters.
2. Remove the 2 metal filters.
3. Locate tabs “A” and slots “B” in the opening. This is where
the filter will fit into place.
B
4. Connect the power supply ground wire to the green ground
screw inside the vent hood terminal box.
A
B
C
E
D
A. White wires B. Green ground screw C. Ground wire
5. Replace the terminal box cover.
D. Black wires
E. Twist-on connectors
Connect the Vent System
Vented installations:
Replace the metal filter. Connect the vent system to the hood vent opening. Seal the connection with clamps.
A
A. Tab B. Slot
4. Place charcoal filter into opening, resting the back of the filter
on tabs “A,” then clip filter tabs “C” into slots “B.”
A
B
C
A
A. Tab B. Slot C. Filter tabs
5. Replace metal filters.
6. Reconnect power.
7. Check the operation of the vent hood fan and light.
8. Push the range hood back in.
To order replacement kits, see the “Assistance or Service” section.
A
A. Filter
11