KitchenAid 9752043 User Manual

Installation Instructions
IMPORTANT: Read and save these instructions.
IMPORTANT: Installer: Leave Installation Instructions with the
homeowner. Homeowner: Keep Installation Instructions and anti-tip bracket template for future reference. Save Installation Instructions for local electrical inspector's use.
www.kitchenaid.com
30" (76.2 cm)
Electric Range
with self-cleaning
thermal/convection oven
Part No.9752043 Rev. B
®
HOME APPLIANCES
Freestanding Range
Slide-in Range
Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is
moved. Failure to follow these instructions can result in
death or serious burns to children and adults.
WARNING
Read electrical and carpentry instructions. Proper installation is your responsibility. A
qualified technician must install this range.Make sure you have everything necessary for correct installation. It is the customer’s responsibility to make sure that the countertop has been properly prepared and that the installation clearances specified on the model/serial rating plate are met.The model/serial rating plate is located on the oven frame behind the drawer.
Check location where range will be installed. The range should be located for convenient use in the kitchen. Recessed installations must provide complete enclosure of the sides and rear of range.
ALL OPENINGS IN THE WALL OR FLOOR WHERE RANGE IS TO BE INSTALLED MUST BE SEALED.
IMPORTANT: Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking and self­cleaning. Check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.
It is the customer’s responsibility: To contact a qualified electrical installer. To assure that the electrical installation is
adiquate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standard C22.1, Canadian Electrical Code, Part 1 — latest edition**, and all local codes and ordinances.

Before you start...

7/8" (2.2 cm) min. required between cutout and cabinet door or hinge.
junction box – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 7" (17.8 cm) max. from floor.
30-3/8" (77.2 cm) opening width
22-3/4" (57.8 cm) opening depth

Cabinet opening dimensions

25" (63.5 cm) countertop depth and 24" (61 cm) base cabinet depth, 36” (91.4 cm) counter top height

Slide-in ranges: countertop preparation

4" (10.2 cm) min. clearance from both sides of range to side wall or other combustible material.
***
Note: 24" (61 cm) min. when bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) min. clearance between the top of the
cooking platform and the bottom of an unprotected wood or metal cabinet.
30" (76.2 cm) min. cabinet opening width
1/2" (1.3 cm) radius both corners
The cooktop sides of the slide-in range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop and the opening width is 30-3/8" (77.2 cm), no
countertop preparation is required. Formed front-edged countertops: Must have
molded edge shaved flat 1/4" (0.64 cm) from each front corner of opening.
Tile countertops may need trim cut back 1/4" (0.64 cm) from each front corner and/or rounded edge flattened.
If countertop opening width is greater than 30-3/8" (77.2 cm), adjust the 1/4" (0.64 cm)
dimension. Countertop must be level. Place level on
countertop, first side to side; then front to back. If countertop is not level, range will not be level. Oven must be level for satisfactory baking conditions.
Important: Observe all governing codes and ordinances.
When installing a range under existing cabinets and the installation does not meet the minimum cabinet clearances, install a range hood above the cooktop to avoid burn hazards.
Grounded electrical outlet is required. See Electrical requirements,” Panel B.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
Do Not pinch the power supply cord between the range and the wall.
Do Not seal range to side cabinets.
For minimum clearance to the top of the cooktop, see Note.***
18" (45.7 cm) upper cabinet to countertop
13" (33 cm) max.
upper cabinet depth
Panel A
1-1/2" (3.8 cm)
25-3/4"
(65.4 cm)
depth with
handle
When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) countertop — front of oven door protrudes 1-7/8" (4.8 cm) beyond 24" (61 cm) base cabinet.
30"
(76.2 cm)
cooktop
width
36" (91.4 cm)
cooktop
height with
feet loosened
1-1/2 turns
36" (91.4 cm) cooktop height with feet loosened 1-1/2 turns
44-3/8" (112.7 cm) overall height
30"
(76.2 cm)
cooktop
width
8-1/4"
(21 cm)

Product dimensions

Freestanding Range Slide-in Range
The floor anti-tip bracket MUST be installed.To install the anti-tip bracket shipped with the range, see Panel C and the anti-tip bracket template.
Anti-tip bracket:
27-3/4"
(70.5 cm)
depth with
handle
22-5/8" (57.5 cm)
30"
(76.2 cm)
width
30"
(76.2 cm)
width
Mobile home installation
The installation of this range must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280); or when such standard is not applicable, the Standard for Manufactured Homes Installations (Manufactured Home Sites, Communities and Setups), ANSI A225.1/NFPA 501A, or with local codes*.
In Canada, the installation of this range must conform with the current standards CAN/CSA-Z240 latest edition**, or with local codes.
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
Four-wire power supply cable must be used in a mobile home installation.The appliance wiring will need to be revised.See four-wire electrical connection, Panel B.
Copies of the standards listed may be obtained from:
*
National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269
**
Canadian Standard Association 178 Rexdale Boulevard Rexdale (Toronto), Ontario M9W 1R3
Formed or tiled countertop trimmed 1/4" (0.64 cm) back at front corners of countertop opening.
30-7/8"
(78.4 cm)
1/4" (0.64 cm)
22-5/8" (57.5 cm)
Note: The metal chassis of the range MUST be
grounded in order for the control panel to work.If the metal chassis of the range is not grounded, NO keypads will operate.Check with a qualified electrician if you are in doubt as to whether the metal chassis of range is grounded.
1" (2.5 cm)
1" (2.5 cm) spacer
30-3/8"
(77.2 cm)
opening
width
Cooktop sides of range fit over edges of countertop opening.
7/8" (2.2 cm) min. required between cutout and cabinet door or hinge.
junction box – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 7" (17.8 cm) max. from floor.
30-1/4" (76.8 cm) opening width
4" (10.2 cm) min. clearance from both sides of range to side wall or other combustible material.
30" (76.2 cm) min. cabinet opening width
For minimum clearance to the top of the cooktop, see Note.***
18" (45.7 cm) upper cabinet to countertop
13" (33 cm) max.
upper cabinet depth
Freestanding Range
Slide-in Range
This is the safety alert symbol. This symbol alerts you to potential hazards
that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:
You can be killed or seriously injured if you don’t follow instructions.
D ANGER
WARNING
Your safety and the safety of others
are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
You can be killed or seriously injured if you don’t immediately
follow instructions.
Loading...
+ 3 hidden pages