Kitchenaid 720-0819g Us Owner's Manual

ITM. / ART. 1500299
2 BURNER OUTDOOR GAS GRILL
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-877-373-2301
or visit our website at www.Kitchenaidgrills.com
Languages spoken: English, Spanish, French 8 a.m.-5 p.m., PST. Monday-Friday.
GRIL À GAZ EXTÉRIEUR À
Instructions d’installation et Guide d’utilisation et d’entretien
Pour des questions à propos des caractéristiques, du fonctionnement/rendement, des pièces, des accessoires ou du service,
composer le: 1-877-373-2301
ou visiter notre site web www.Kitchenaidgrills.com
Langues parlées: anglais , espagnol, français entre 8 h et 17 h, HNP, du lundi au vendredi.
PARILLA DE GAS PARA EXTERIORES
CON 2 MECHEROS
Instrucciones de instalación y Manual de uso y cuidado
Para consultas respecto a características, funcionamiento, rendimiento, piezas, accesorios o servicio técnico, llame al: 1-877-373-2301
o visite nuestro sitio de internet en www.Kitchenaidgrills.com
Lenguages ablados: Ingles, Espanol y Frances de 8 a.m.-5 p.m., PST. Lunes-Viernes.
Table of Contents / Table des matières / Índice ................................................................. 2
For outdoor use only. Not for commercial use. Pour usage extérieur seulement. Pas à des fins commerciales. Para uso al aire libre solamente. No para uso comercial.
Keep this manual for future reference. Conserver ce manuel à titre de référence ultérieure. Conserve el presente manual para consultas futuras.
720-0819G (LP) / 730-0819G (NG)
19000672A0
TABLE OF CONTENTS
OUTDOOR GRILL SAFETY ………………………….…………3
PACKAGE PARTS LIST ......................................................5
ASSEMBLY INSTRUCTIONS .…………………....……….……8
INSTALLATION REQUIREMENTS ……..………………....24
Location Requirements ……………..………………...………24 Product Dimensions ………………………………………….24 Gas Supply Requirements ……………………….……….….…25 Gas Connection Requirements …………………....……..25 Make Gas Connection …………….…………….………………27
GAS CONVERSION ………………………………...............28
Tools and Parts for Gas Conversion ………………….........28
Conversion from LP Gas to Natural Gas ………………......28
Make Gas Connection ……………………............……………29
Checking and Adjusting Burners ……….………..………….31
OUTDOOR GRILL USE ….……….…………..…….……….32 Using Your Outdoor Grill ……………………….…………….32 TIPS FOR OUTDOOR GRILLING ……………..……………...34 Cooking Methods ………………….…………………………….34 Grilling Chart ………………………….………………...……..35 OUTDOOR GRILL CARE ………………………………...……37
Replacing the Igniter Battery …….…………….……....……....37
General Cleaning ………………………………………......37
TROUBLESHOOTING ...........................................................39
ASSISTANCE ………………………………….…………….….39
Accessories ………………………………………………..……..39
WARRANTY ……………………………………….…………….40
REPLACEMENT PARTS…………………….…………....……82
TABLE DES MATIÈRES
SÉCURITÉ DU GRIL D'EXTÉRIEUR ……….…...…..…….42
LISTE DES PIÈCES DE L’EMBALLAGE ...............................5
CONSIGNES POUR L’ASSEMBLAGE ……………….............8
EXIGENCES D’INSTALLATION …………………..…….....…44
Exigences d'emplacement ………………………..……………44 Dimensions du produit …………………………………….....44 Spécifications de l'alimentation en gaz …………………….45 Exigences concernant le raccordement au gaz …….……..46 Raccordement au gaz ………..…………………………………47 CONVERSIONS POUR CHANGEMENT DE GAZ ………….48
Outils et pièces pour conversion de gaz …………...………....48
Conversion de propane à gaz naturel ……………….......48
Raccordement au gaz ………………………….................49
Contrôle et réglage des brûleurs …………………………....51
UTILISATION DU GRIL D’EXTÉRIEUR …….………………….....52
Utilisation de votre gril d'extérieur ………..…….…….……….52
CONSEILS POUR L'UTILISATION DU GRIL
D’EXTÉRIEUR …………………………..……….........……..54
Méthodes de cuisson …………………..………....……….54 Tableau de cuisson au gril …………………………..……....55 ENTRETIEN DU GRIL D’EXTÉRIEUR ……………………….57 Remplacement de la pile de l’allumeur …….....………….57 Nettoage général ………………………………...……….……..57
DÉPANNAGE .........................................................................59
ASSISTANCE ……………………………………..…………..59
Accessoires ………………………………………………………59
GARANTIE ……………………………………..……..……...….60 PIÈCES DE RECHANGE …………………..…………...…...82
ÍNDICE
SEGURIDAD DEL ASADOR PARA EXTERIORES..........62
LISTA DE CONTENIDO DEL PAQUETE ………………....…..5
INSTRUCCIONE DE MONTAJE …………………....……….8 REQUISITOS DE INSTALACIÓN …………..………………...64
Requisitos de ubicación …………………………….……….....64
Medidas del producto …………………………………………..64
Requisitos del suministro de gas ……………………...........65
Requisitos para la conexión de gas ……………………..........66
Conexión del suministro de gas …………………………….....67
CONVERSIONES DE GAS …………………………........68
Herramientas y piezas para la conversión de gas ..............68
Conversión de gas LP a gas natural …………………..………68 Conexión del suministro de gas ……………………………….68
Revise y regule los quemadores ………………………........71
USO DEL ASADOR PARA EXTERIORES………….………..72 Cómo usar el asador para exteriores ………………………….72 CONSEJOS PARA ASAR AL AIRE LIBRE…………….....74 Métodos de cocción ………………………………………....74
Cuadro para asar …………………………………………......75
CUIDADO DEL ASADOR PARA EXTERIORES……...……..77 Cómo reemplazar la batería del encendedor …………...……77 Limpieza general …………………………………………...……77
SOLUCIÓN DE PROBLEMAS...............................................79
ASISTENCIA ………………………………………….……..…..79
Acesorios …………………………………………………………79
GARANTÍA ……………………………………………..……......80
PIEZAS DE REPUESTO…………………………….............…82
2
OUTDOOR GRILL SAFETY
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or your fire department.
WARNING
1. Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
IMPORTANT: This grill is manufactured for outdoor use only. For grills that are to be used at elevations above 609.6 m (2,000 ft.)
orifice conversion is required. See "Gas Supply Requirements" section. It is the responsibility of the installer to comply with the minimum installation clearances specified on the model/serial rating plate. The model/serial rating plate for freestanding models can be found on the left-hand cabinet door.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type. A flexible gas connector, when used, must not exceed 91.44 cm (3 feet).
CALIFORNIA RESIDENTS ONLY - WARNING:
This product and the fuels used to operate this product (liquid propane), and the products of combustion of such fuels, can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm.
For more information go to: www.P65Warnings.ca.gov.
3
2.54 cm (1")
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electrical shock, Injury to persons, or damage when using the outdoor cooking gas appliance, follow basic precautions, including the following:
Do not install portable or built-in outdoor cooking gas
appliances in or on a recreational vehicle, portable trailer, boat or in any other moving installation.
Always maintain minimum clearances from combustible
construction, see "Location Requirements" section.
The outdoor cooking gas appliance shall not be located
under overhead unprotected combustible construction.
This outdoor cooking gas appliance shall be used only
outdoors and shall not be used in a building, garage, or any other enclosed area.
Keep any electrical supply cord and fuel supply hose away
from any heated surfaces.
Keep outdoor cooking gas appliance area clear and free
from combustible material, gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air.
Keep the ventilation openings of the cylinder enclosure free and clear from debris.
Open the cabinet door and inspect the gas cylinder supply
hose before each use of the outdoor cooking gas
appliance. If the hose shows excessive abrasion or wear, or is cut, it MUST be replaced before using the outdoor cooking gas appliance. Contact your dealer and use only replacement hoses specified for use with the outdoor cooking gas appliance.
Visually check the burner flames.
They should be blue. Slight yellow tipping is normal for LP gas. The flames should be approximately 2.54 cm (1") high.
Check and clean burner/venturi tube for insects and insect
nest. A clogged tube can lead to fire under the outdoor cooking gas appliance.
The LP gas supply cylinder to be used must be:
- constructed and marked in accordance with the Specification for LP Gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-b339, Cylinders, Spheres, and Tubes for Transportation of Dangerous Goods; and Commission.
- provided with a listed overfilling prevention device.
- provided with a cylinder connection device compatible with the connection for outdoor cooking gas appliances.
Always check connections for leaks each time you connect
and disconnect the LP gas supply cylinder. See "Installation Instructions" section.
When the outdoor cooking gas appliance is not in use, the
gas must be turned off at the supply cylinder.
Storage of an outdoor cooking gas appliance indoors is
permissible only if the cylinder is disconnected and removed from the outdoor cooking gas appliance.
Cylinders must be stored outdoors and out of the reach of
children and must not be stored in a building, garage, or any other enclosed area.
The pressure regulator and hose assembly supplied with
the outdoor cooking gas appliance must be used. A
replacement pressure regulator and hose assembly specific to your model is available from your outdoor cooking gas appliance dealer.
Gas cylinder must include a collar to protect the cylinder
valve.
For appliances designed to use a CGA791 connection:
Place a dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
If the following information is not followed exactly, a fire causing
death or serious injury may occur.
Do not store a spare LP gas cylinder under or near this
outdoor cooking gas appliance.
Never fill the cylinder beyond 80 percent full.
SAVE THESE INSTRUCTIONS
4
Package Parts List
Lista de contenido del paquete
Liste des pièces de l'emballage
5
7
3
6
8
4
1 2510
Package Parts List
Lista de contenido del paquete
Liste des pièces de l'emballage
13
15
11
14
16
12
x2
x2
9
6
Package Parts List
Lista de contenido del paquete
Liste des pièces de l'emballage
21
19
22
20
17 18
x2
x2 x2
23
7
Hardware Package List
Lista de tornillos del paquete
Liste des vis de l'emballage
Tools Needed / Herramientas necesarias / Outillage Requis
ASSEMBLY INSTRUCTIONS/INSTRUCCIONES DE ENSAMBLAJE/CONSIGNES POUR L’ASSEMBLAGE
Some parts come with screws pre­installed. Loosen and tighten for final assembly.
Algunas partes vienen con los tornillos pre instalados. Afloje y apriete para el ensamble final.
Certaines pièces sont livrées avec les vis pré-installées. Desserrez et resserrez pour l'assemblage final.
Truss Head Screw 1/4-20 x 1/2"
Tornillo de cabeza ovalada 1/4-20 x 1/2"
Vis cruciforme 1/4-20 x 1/2"
A
x25
Flat head screw 5/32-32 x 3/8"
Tornillo de cabeza plana 5/32-32 x 3/8"
Vis à tête plate 5/32-32 x 3/8"
D
x12
Self-Tapping Screw #8 x 3/8"
Tornillo autorroscante #8 x 3/8"
Vis autotaraudeuse #8 x 3/8"
C
x4
Truss Head Screw 5/32-32 x 2/5"
Tornillo de cabeza ovalada 5/32-32 x 2/5"
Vis cruciforme 5/32-32 x 2/5"
B
x8
8
1.
2.
9
3.
4.
10
5.
6.
11
7.
8.
12
10.
9.
13
11.
12.
14
13.
14.
15
15.
16.
16
17.
18.
17
19.
20.
18
21.
22.
19
23.
24.
20
25.
26.
21
27.
28.
22
29.
30.
23
INSTALLATION REQUIREMENTS
Select a location that provides minimum exposure to wind and traffic paths. The location should be away from strong draft areas. Do not obstruct flow of combustion and ventilation air. Clearance to combustible construction for grill:
A minimum of 91.44 cm (36") must be maintained between
the front of the grill hood, sides and back of the grill and any combustible construction.
A 91.44 cm (36") minimum clearance must also be
maintained below the cooking surface, and the grill shall not be used under overhead combustible construction.
Rotisserie (accessory is not included)*
If you equip your grill with a rotisserie, a 15.2 cm (6") minimum clearance is needed for the rotisserie motor.
A grounded, 3-prong outlet located to the left of the grill is required.
*See "Assistance" section to order.
Product Dimensions
The model/serial number rating plate is located on the inside of the cabinet door. See the following illustration.
A
A. Model/serial number plate
Location Requirements
116.24cm/45.76in/45.76po
124.02cm/48.82in/48.82po
62.15cm/24.46in/24.46po
24
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local
codes and ordinances. In the absence of local codes, installation must conform with either the National Fuel Gas Code, ANSI Z223.1/NFPA54, Natural Gas and Propane Installation Code, CSA B149.1, Propane Storage And Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A119.2/NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable.
IMPORTANT: Grill must be connected to a regulated gas supply. Refer to the model/serial rating plate for information on the type of gas that can be used. If this information does not agree with the type of gas available, check with your local gas supplier.
Gas Conversion:
No attempt shall be made to convert the grill from the gas specified on the model/serial rating plate for use with a different gas type without consulting the serving gas supplier. The conversion kit supplied with grill must be used. See "Gas Conversions" section for instructions.
Gas Pressure Regulator
The gas pressure regulator supplied with this grill must be used. The inlet (supply) pressure to the regulator should be as follows for proper operation:
LP Gas:
Operating pressure: 2.74 kPa (11" WCP)
Inlet (supply) pressure: 2.74 to 3.48 kPa (11" to 14" WCP)
Natural Gas:
Operating pressure: 1.00 kPa (4" WCP) Inlet (supply) pressure: 1.74 to 3.48 kPa (7" to 14" WCP) maximum. Contact local gas supplier if you are not sure about the inlet (supply) pressure.
Gas Supply Requirements
Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 609.6 m (2,000 ft.). For elevations above 609.6 m (2,000 ft.), ratings are reduced at a rate of 4% for each 304.8 m (1,000 ft.) above sea level. Orifice conversion is required. See "Assistance" section to order.
Gas Supply Line Pressure Testing
Testing above 3.5 kPa(1/2 psig) or 14" WCP (gauge):
The grill and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 3.5 kPa (1/2 psig).
Testing below 3.5 kPa (1/2 psig) or 14" WCP (gauge) or
lower:
The grill must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 3.5 kPa (1/2 psig).
Gas Connection Requirements
9 kg (20 lb) LP Gas Fuel Tank
This grill is equipped for use with a 9 kg (20 lb) LP gas fuel tank (fuel tank not supplied). A gas pressure regulator/hose assembly is supplied.
Any brand of 9 kg (20 lb) LP gas fuel tank is acceptable for use
with the grill, provided that it is compatible with the grill’s
retention means (tank tray included). It is also design-certified by CSA International for local LP gas supply or for Natural gas with appropriate conversion.
A. Gas pressure regulator/hose assembly
A. Tank tray locking bracket
A
The 9 kg (20 lb) LP gas fuel tank must be mounted and secured.
Door Style Tank Tray
1. Open cabinet door.
2. Slide the tank tray locking bracket counterclockwise 90º and pull out the tray
A
25
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The qualified Natural gas technician shall provide the Natural gas supply to the selected grill location in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. For conversion to Natural gas, the Natural Gas Conversion Kit supplied with the grill (on some models) or the Natural Gas Conversion Kit Part Number 710-0003 must be used. See "Assistance" section for information on ordering.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. Follow instructions for converting to Natural gas in the "Gas Conversions" section of this manual or the instructions supplied with Natural Gas Conversion Kit Part Number 710-0003. The gas supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the grill and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the grill.
A. Gas supply line
B. Shutoff valve "open" position
C. To grill
A
B
C
A. Locking screw B. Bottom collar C. Mounting hole
5. Slide the drawer with the 20 lb LP gas fuel tank back into the cabinet. Turn the tank tray locking bracket clockwise 90º to tighten.
A
A. Tank tray locking bracket
3. Place the 9 kg (20 lb) LP gas fuel tank bottom collar into the mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the 9 kg (20 lb) LP gas fuel tank to secure.
26
Loading...
+ 60 hidden pages