Location requirements…………………………………..……19
Product Dimensions……………………………….…………19
Gas Supply Requirements…………………………………20
Gas Connection Requirements…………………..………20
Make Gas Connection ………………………………………..…22
GAS CONVERSION………………………………….............23
Tools and Parts for Gas Conversion …………………....23
Conversion from LP Gas to Natural Gas………………….23
Make Gas Connection…………………………...……..……24
Checking and Adjusting Burners… …… … … ….……25
ÍNDICE
OUTDOOR GRILL USE …………………………………………26
Using Your Outdoor Grill ………………………………..….…26
TIPS FOR OUTDOOR GRILLING ……………………….…..28
Cooking Methods ………………….………………………...….28
Grilling Chart ………………………….……………………....….29
OUTDOOR GRILL CARE …………………………………..…31
Replacing the Igniter Battery …….………………….………....31
LISTA DE CONTENIDO DEL PAQUETE………………...…..5
INSTRUCCIONES DE MONTAJE…………………..….….…..7
REQUISITOS DE INSTALACIÓN…………..………………..38
Requisitos de ubicación ……………………………...……….38
Medidas del producto ……………………………….………38
Requisitos del suministro de gas ………………………….....39
Requisitos para la conexión de gas …………………...…….40
Conexión del suministro de gas ………………………41
CONVERSIONES DE GAS ……………………………..….42
Herramientas y piezas para la conversión de gas ..........….42
Conversión de gas LP a gas natural …………………………42
Revise y regule los quemadores ……………………...……...44
TABLE DES MATIÈRES
SÉCURITÉ DU GRIL D'EXTÉRIEUR ………………….……56
LISTE DES PIÈCES DE L’EMBALLAGE...............................5
CONSIGNES POUR L’ASSEMBLAGE………………..….……7
EXIGENCES D’INSTALLATION…………………………..…58
Exigences d'emplacement ……………………………………58
Dimensions du produit ……………………………………...…..58
Spécifications de l'alimentation en gaz ………………..……59
Exigences concernant le raccordement au gaz………………60
Raccordement au gaz……………………………………………61
CONVERSIONS POUR CHANGEMENT DE GAZ …….…....62
Outils et pièces pour conversion de gaz ………….……..…...62
Conversion de propane à gaz naturel ……………….…...…...62
Raccordement au gaz …………………………............…..….63
Contrôle et réglage des brûleurs ……………………….……...64
USO DEL ASADOR PARA EXTERIORES …………………...46
Cómo usar el asador para exteriores …………………………..46
CONSEJOS PARA ASAR AL AIRE LIBRE …………………..48
Métodos de cocción ………………………………………...…...48
Cuadro para asar ……………………………………………...….49
CUIDADO DEL ASADOR PARA EXTERIORES ………….….51
Cómo reemplazar la batería del encendedor …………………51
Limpieza general ………………………………………………….51
SOLUCIÓN DE PROBLEMAS.................................................53
ASISTENCIA………………………………………………..……..53
GARANTÍA …………………………………………………..…....54
PIEZAS DE REPUESTO ……………………………...………77
UTILISATION DU GRIL D’EXTÉRIEUR…….………………...65
Utilisation du gril d’extérieur…………………………………….65
C O N SEI L S P O UR L 'U T I LI S A TI O N DU G RI L
D’EXTÉRIEUR…………………………………...……… .…. 67
Méthodes de cuisson ……………………………...………….…67
Tableau de cuisson au gril ………………………...……...….….68
ENTRETIEN DU GRIL D’EXTÉRIEUR……………………...70
Remplacement de la pile de l’allumeur……………………….70
Nettoyage général …………………………………….……….70
ASSISTANCE……………………………………………….…72
GARANTIE…………………………………………………...…..73
PIÈCES DE RECHANGE …………………………………...…78
OUTDOOR GRILL SAFETY
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from
the appliance and immediately call
your gas supplier or your fire
WARNING
1. Do not store or use gasoline or other
flammable liquids or vapors in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
department.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed
by the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT: This grill is manufactured for outdoor use only. For grills that are to be used at elevations above 2,000 ft (609.6 m)
orifice conversion is required. See “ Gas Supply Requirements” section. It is the responsibility of the installer to comply with the
minimum installation clearances specified on the model/serial rating plate. The model/serial rating plate for freestanding models can
be found on the left-hand cabinet door.
3
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electrical shock,
Injury to persons, or damage when using the outdoor cooking
gas appliance, follow basic precautions, including the following:
Do not install portable or built-in outdoor cooking gas
appliances in or on a recreational vehicle, portable
trailer, boat or in any other moving installation.
Always maintain minimum clearances from
combustible construction, see “ Location Requirements” section. The outdoor cooking gas appliance shall not be located
under overhead unprotected combustible construction.
This outdoor cooking gas appliance shall be used only
outdoors and shall not be used in a building, garage, or
any other enclosed area.
Keep any electrical supply cord and fuel supply hose
away from any heated surfaces.
Keep outdoor cooking gas appliance area clear and
free from combustible material, gasoline and other
flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation
air. Keep the ventilation openings of the cylinder
enclosure free and clear from debris.
Open the cabinet door and inspect the gas cylinder supply
hose before each use of the outdoor cooking gas appliance.
If the hose shows excessive abrasion or wear, or is cut, it
MUST be replaced before using the outdoor cooking gas
appliance. Contact your dealer and use only replacement
hoses specified for use with the outdoor cooking gas
appliance.
Visually check the burner flames.
They should be blue. Slight
yellow tipping is normal for
LP gas. The flames should
be approximately 1" (2.5 cm) high.
Check and clean burner/venturi tube for insects and
insect nest. A clogged tube can lead to fire under the
outdoor cooking gas appliance.
The LP gas supply cylinder to be used must be:
- constructed and marked in accordance with the
Specification for LP Gas cylinders of the U.S.
Department of Transportation (DOT) or the
National Standard of Canada, CAN/CSA-b339,
Cylinders, Spheres, and Tubes for Transportation
of Dangerous Goods; and Commission.
- provided with a listed overfilling prevention device.
- provided with a cylinder connection device
compatible with the connection for outdoor cooking
gas appliances.
Always check connections for leaks each time you
connect and disconnect the LP gas supply cylinder.
See “Installation Instructions” section. When the outdoor cooking gas appliance is not in
use, the gas must be turned off at the supply cylinder.
Storage of an outdoor cooking gas appliance indoors
is permissible only if the cylinder is disconnected
and removed from the outdoor cooking gas appliance.
Cylinders must be stored outdoors and out of the
reach of children and must not be stored in a
building, garage, or any other enclosed area.
The pressure regulator and hose assembly supplied
with the outdoor cooking gas appliance must be
used. A replacement pressure regulator and hose
assembly specific to your model is available from
your outdoor cooking gas appliance dealer.
Gas cylinder must include a collar to protect the
cylinder valve.
For appliances designed to use a CGA791
Connection: Place a dust cap on cylinder valve
outlet whenever the cylinder is not in use. Only
install the type of dust cap on the cylinder valve
outlet that is provided with the cylinder valve. Other
types of caps or plugs may result in leakage of
propane.
If the following information is not followed
exactly, a fire causing death or serious injury may occur.
Do not store a spare LP gas cylinder under or near
this outdoor cooking gas appliance.
Never fill the cylinder beyond 80 percent full.
4
SAVE THESE INSTRUCTIONS
Package parts List
Lista de contenido del paquete
Liste des pièces de l'emballage
1
3
5
2
4
6
7
9
8
10
x3
5
Package parts List
Lista de contenido del paquete
Liste des pièces de l'emballage
11 12
13
x2
14
x3
6
ASSEMBLY INSTRUCTIONS/INSTRUCCIONES DE ENSAMBLAJE/CONSIGNES POUR L’ASSEMBLAGE
Some parts come
with Screws preinstalled.
Loosen and tighten
for final assembly.
Algunas partes
vienen con los
tornillos pre
instalados.
Afloje y apriete para
el ensamble final.
Certaines pièces sont
livrées avec les vis
pré-installées.
Desserrez et
resserrez pour
l'assemblage final.
Hardware package list/ Lista de tornillos del paquete
Liste des vis de l'emballage
Truss Head Screw
1/4 - 20 x 5/8"
Tornillo de cabeza ovalada
1/4 - 20 x 5/8"
Vis cruciforme 1/4 - 20 x 5/8"
Truss Head Screw
5/32 - 32 x 3/8"
Tornillo de cabeza ovalada
5/32 - 32 x 3/8"
Vis cruciforme 5/32 - 32 x 3/8"
A
x22 B
Flat Head Screw
5/32-32x3/8"
Tornillo de cabeza plana
5/32-32x3/8"
vis à tête plate 5/32-32x3/8"
x4
C
x2
Stage Screw 1/4 x 5/16“
Etapa Tornillo 1/4 x 5/16“
Etape vis 1/4 x 5/16"
x4
D
7
1
A
x16
2
8
2
3
3
4
4
5
9
A
Ax2
5
B
6
x2
x2
Bx2
C
6
8
x4
10
7
7
8
1
11
9
A
x2
Cx4
Bx4
10
A
x2
12
11
11
11
12
D
x4
13
13
9
14
10
14
15
12
16
13
15
17
18
16
19
20
14
+
-
17
21
22
18
INSTALLATION REQUIREMENTS
Location Requirements
Product Dimension
Select a location that provides minimum exposure to wind
and traffic paths. The location should be away from strong
draft areas.
Do not obstruct flow of combustion and ventilation air.
Clearance to combustible construction for grill:
A minimum of 36” (92 cm) must be maintained between
the front of the grill hood, sides and back of the grill
and any combustible construction.
A 36” (92 cm) minimum clearance must also be
maintained below the cooking surface, and the grill
shall not be used under overhead combustible
construction.
Rotisserie (accessory – not included)*
If you equip your grill with a rotisserie, a 6" (15.2 cm)
minimum clearance is needed for the rotisserie motor.
A grounded, 3-prong outlet located to the left of the grill is
required.
*See “Assistance” section to order.
The model/serial number rating plate is located on the inside of the
left cabinet door. See the following illustration.
A
19
Gas Supply Requirements
Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice
conversion is required. See “Assistance” section to order.
The grill and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures greater than 1/2 psi (3.5 kPa).
Testing below 1/2 psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge)
or lower:
The grill must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
Gas Connection Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with either the National Fuel Gas Code, ANSI
Z223.1/NFPA54, Natural Gas and Propane Installation Code,
CSA B149.1, Propane Storage And Handling Code, B149.2, or
the Standard for Recreational Vehicles, ANSI A119.2/NFPA
1192 and CSA Z240 RV Series Recreational Vehicle Code as
applicable.
IMPORTANT: Grill must be connected to a regulated gas supply.
Refer to the model/serial rating plate for information on the type
of gas that can be used. If this information does not agree with
the type of gas available, check with your local gas supplier.
Gas Conversion:
No attempt shall be made to convert the grill from the gas
specified on the model/serial rating plate for use with a different
gas type without consulting the serving gas supplier. The
conversion kit supplied with grill must be used. See “Gas
Conversions” section for instructions.
Gas Pressure Regulator
The gas pressure regulator supplied with this grill must be used.
The inlet (supply) pressure to the regulator should be as follows
for proper operation:
LP Gas:
Operating pressure: 11" (27.9 cm) WCP
Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP
Natural Gas:
Operating pressure: 4" (10.2 cm) WCP
Inlet (supply) pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP
maximum.
Contact local gas supplier if you are not sure about the inlet
(supply) pressure.
20 lb LP Gas Fuel Tank
This grill is equipped for use with a 20 lb LP gas fuel tank (fuel
tank not supplied). A gas pressure regulator/hose assembly is
supplied.
Any brand of 20 lb LP gas fuel tank is acceptable for use with
the grill, provided that it is compatible with the grill’s retention
means (tank tray included).
It is also design-certified by CSA International for local LP gas
supply or for Natural gas with appropriate conversion.
A
A. Gas pressure regulator/Hose assembly
20
The 20 lb LP gas fuel tank must be mounted and secured.
Door Style Tank Tray
1. Open cabinet door.
2. Slide the tank tray locking bracket counterclockwise 90 º
and pull out the tray
A
A. Tank tray locking bracket
3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of
the 20 lb LP gas fuel tank to secure.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected grill location in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition,
and local codes. For conversion to Natural gas, the Natural Gas
Conversion Kit supplied with the grill (on some models) or the
Natural Gas Conversion Kit Part Number 710-0003 must be
used. See “Assistance” section for information on ordering.IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
Follow instructions for converting to Natural gas in the “Gas
Conversions” section of this manual or the instructions supplied
with Natural Gas Conversion Kit Part Number 710-0003.
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the grill
and should be in a location that allows ease of opening and
closing. Do not block access to the shutoff valve. The valve is
for turning on or shutting off gas to the grill.
A
5. Slide the drawer with the 20lb LP gas fuel tank back into the
cabinet. Turn the tank tray locking bracket clockwise 90º to
tighten.
B
A. Locking screw
B. Bottom collar
C. Mounting hole
A
A. Tank tray locking bracket
C
A. Gas supply line
B. Shutoff valve “open” position
C. To grill
21
Make Gas Connection
NOTE: If grill is to be converted to Natural gas, follow
instructions in the “Gas Conversions” section.
20 lb LP Gas Fuel Tank
LPGas:
IMPORTANT: A 20 lb LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the grill must be used. Replacement gas pressure
regulator/hose assembly specific to your model is available from
your outdoor grill dealer.
To Connect the 20 lb LP Gas Fuel Tank:
1. Check that the 20 lb LP gas fuel tank is in the “Off”
position. If not, turn the valve clockwise until it stops.
2. Check that the 20 lb LP gas fuel tank valve has the proper
type-1 external male thread connections per ANSI Z21.81.
3. Check that the burner control knobs are in the “Off”
position.
4. Remove any debris and inspect the valve connections,
port, and gas pressure regulator/hose assembly for
damage.
NOTE: Always keep the LP cylinder at 90° (upright)
orientation to provide vapor withdrawal.
A
B
A. Gas pressure regulator/hose assembly
B. 20 lb LP gas fuel tank
Make sure that the cylinder valve connection device
properly mates with the connection device attached to
the inlet of the pressure regulator.
6. Open the tank valve fully by turning the valve
counterclockwise. Wait a few minutes for gas to move
through the gas line.
7. Before lighting the grill, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak.
8. If a leak is found, turn the tank valve off and do not use
the grill. Contact a qualified gas technician to make
repairs.
9. Go to “Check and Adjust the Burners” section.
To Disconnect the 20 lb LP Gas Fuel Tank:
1. Check that the burner control knobs are in the “Off” position
and the grill is cool.
2. Check that the 20 lb LP gas fuel tank is in the “Off” position.
If not, turn the valve clockwise until it stops.
3. Using your hand, turn the gas pressure regulator/hose
assembly counterclockwise to disconnect to the 20 lb LP gas
fuel tank as shown.
Hand loosen only. Use of a wrench could damage the quick
coupling nut.
5. Using your hand, turn the gas pressure regulator/hose
assembly clockwise to connect to the 20 lb LP gas fuel
tank as shown.
Hand tighten only. Use of a wrench could damage the
quick coupling nut.
22
A
B
A. Gas pressure regulator/hose assembly
B. 20 lb LP gas fuel tank
4. Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap on
the valve outlet that is provided with the cylinder valve.
Other types of caps or plugs may result in leakage of
propane.
GAS CONVERSIONS
Tools and Parts for Gas Conversion
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
6mm
Parts supplied
Natural gas orifices
Parts needed
Natural gas conversion kit Part Number 710-0003. See
“Assistance” section to order. The conversion kit includes:
Natural gas regulator 4" W.C. (marked “Natural Gas
Regulator”)
10 ft (3.0 m) Natural gas hose with Quick Connector
assembly 5.9" (150 mm)
6 mm nut driver
6 mm wrench
Hex key
Flat washer
Truss head screw with lock
IMPORTANT: Gas conversions must be done by a qualified
installer. Before proceeding with conversion, shut off the gas
supply to the grill.
Conversion from LP Gas to Natural
Gas
Installation of the regulator
1. Turn off the main gas supply valve.
2. Disconnect 20 lb LP gas fuel tank (if present).
3. Turn off all burner control valves.
4. Remove the 20 lb LP gas fuel tank (if present) from
the grill cart.
5. Use an adjustable wrench to remove the LP
regulator from the manifold.
6. Use an adjustable wrench to install the Natural gas
regulator hose to the manifold and secure. Attach the
Natural gas regulator to the side panel inside the grill
cart with the two screws that are preassembled on the
regulator.
23
Make Gas Connection
1.A combination of pipe fittings must be used to connect the
grill to the existing gas line.
The 10 ft (3.0 m) PVC flexible gas supply hose design
certified by CSA must be used.
Pipe-joint compounds suitable for use with Natural gas
must be used. Do not use Teflon®+ tape.
There must be a certified manual shut-off valve in the gas
supply line near the grill for easy access.
2. Connect the brass connector on one end of the 10 ft (3.0 m)
PVC flexible gas supply hose to the Natural gas pressure
regulator.
3. Connect the quick connector on the other end of the
10 ft (3.0 m) PVC flexible gas supply hose to the rigid Natural
gas supply pipe.
Change Grill Main Burner Valve Orifices
1. Remove the grates and flame tamers.
2. Remove the 2 screws and cotter clip that hold the burner
in place. Set the screw and clip aside. Remove the burner
from the grill by lifting the burner out.
3. Use a 6 mm socket and wrench or 6 mm nut driver to
remove the brass orifice from the end of gas valve. The
main burner NG orifice is located behind the LP orifice,
so no additional orifice needs to be installed.
4. Reinsert the burner and reattach using the 2 screws
and cotter clip previously removed. Repeat the
procedure for each main burner.
IMPORTANT: Open left and right door. Check that the LP
orifice is properly removed inside of the burner venturi from
the hole of the heat shield under the firebox by using a
flashlight.
5. Position the igniters so they are 1/8" (3.2 mm) away
from each burner.
Adjust High Flame Setting Screw
When converting from LP to Natural gas, you will need to adjust
the high flame setting screw for ideal burner flame height.
1. Remove each control knob for the main burners.
† ®TEFLON is a registered trademark of E.I. Du Pont De
Nemours and Company.
24
2. Use a flat-blade screwdriver to turn the high flame
setscrew counterclockwise approximate 90º.
Loading...