King Canada 8449C User Manual

07/2015
1.5 HP AIR COMPRESSOR
MODEL: 8449C
INSTRUCTION MANUAL
COPYRIGHT © 2015 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.
WARRANTY INFORMATION
2-YEAR
LIMITED WARRANTY
PROOF OF PURCHASE
Please keep your dated proof of purchase for warranty and servicing purposes.
REPLACEMENT PARTS
Replacement parts for this product are available at our authorized King Canada service centers across Canada.
LIMITED TOOL WARRANTY
King Canada makes every effort to ensure that this product meets high quality and durability standards. King Canada warrants to the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, normal wear and tear, negligence or accidents, repairs done by an unauthorized service center, alterations and lack of maintenance. King Canada shall in no event be liable for death, injuries to persons or property or for incidental, special or consequential damages arising from the use of our products.
To take advantage of this limited warranty, return the product at your expense together with your dated proof of purshase to an authorized King Canada service center. Contact your retailer or visit our web site at www.kingcanada.com for an updated listing of our authorized service centers. In cooperation with our authorized serviced center, King Canada will either repair or replace the product if any part or parts covered under this warranty which examination proves to be defective in workmanship or material during the warranty period.
OFFERS A 2-YEAR LIMITED WARRANTY
KING CANADA TOOLS
FOR NON-COMMERCIAL USE.
NOTE TO USER
This instruction manual is meant to serve as a guide only. Specifications and references are subject to change without prior notice.
KING CANADA INC. DORVAL, QUÉBEC, CANADA H9P 2Y4
www.kingcanada.com
IMPORTANT SAFETY INSTRUCTIONS
RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN
HOW TO PREVENT IT
It is normal for electrical contacts within the motor and pressure switch to spark.
If electrical sparks from the compressor come in contact with flammable vapors, they may ignite, causing fire or explosion. Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.
Unattended operation of this compressor could result in per­sonal injury or property damage.
RISK OF BURSTING
WHAT CAN HAPPEN
1. Failure to properly drain condensed water from the tank, causing rust and thinning of the steel tank.
2. Modifications or attempted repairs to the tank.
3. Unauthorized modifications to the unloader valve, safety valve or any other components which control tank pressure.
4. Excessive vibration can weaken the air tank and cause rup­ture or explosion.
Attachments & Accessories; Exceeding the operating pressure of air tools can cause them to explode.
Always operate the compressor in a well ventilated area free of combustible materials, gasoline or solvent vapors. If spraying flammable materials, locate the compressor at least 20 feet away from the spray area. An additional length of hose may be required. Store flammable materials in a secure location away from the compressor. Never place objects against or on top of the compressor. Oper­ate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow or fresh air to the ventilation openings. Operate compressor in a clean, dry and well ventilated area. Do not operate compressor indoors in a confined area. Always remain in attendance with the compressor when it is op­erating.
HOW TO PREVENT IT
Drain tank daily or after every use. If the tank developes a leak, replace tank or get a new air compressor. Never drill into, weld or make any modifications to the tank or its attachments.
The tank is designed to withstand specific operating pressures. Never make adjustments or parts substitutions to alter the fac­tory set operating pressures.
For essential control of air pressure, you must install a pressure regulator and pressure gauge to the air outlet.
RISK OF BURNS
WHAT CAN HAPPEN
Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR
WHAT CAN HAPPEN
Oil can leak or spill and could result in fire or breathing hazard, serious injury or death can result. Oil leaks will damage carpet, paint or other surfaces in vehicules or trailers.
HOW TO PREVENT IT
Never touch any exposed metal parts on compressor during or immediately after operation. The compressor will remain hot several minutes after use.
Do not reach around protective shrouds or attempt maintenance until the compressor has cooled down completely.
HOW TO PREVENT IT
Always place compressor on a protective mat when transporting to protect against damage to vehicule from leaks. Remove com­pressor from vehicule immediately apon arrival.