1394 South Third Street, Mebane NC 27302
1-800-880-6788 • www.kiddeus.com
Architectural and Engineering
Specifications
The smoke alarm shall be Kidde Unit PI9000 or approved
equal. It shall be powered by a 9V battery. The unit shall
incorporate both an ionization smoke sensor and a photoelectric smoke sensor with a nominal alarm sensitivity of
1.99%/ft. The temperature operating range shall be
between 40˚F and 100˚F (4˚C and 38˚C) and the humidity
operating range shall be 5% - 95% relative humidity.
The alarm can be installed on the surface of any wall or
ceiling following the UL/NFPA/Manufacturer’s recommended
placement guidelines. The unit shall provide optional tamper resistance that deters removal of the unit from the wall
or ceiling.
The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to
go into alarm. This sequence tests the unit’s electronics,
battery and horn to ensure proper operation.
The unit shall include a piezoelectric horn that is rated
at 85 decibels at 10 feet. In a smoke incident, the horn will
sound in the repetitive manner – three (3) beeps, a pause,
three (3) beeps, a pause.
The unit shall include the Hush
®
feature that silences
the unit. By pressing the Hush
®
button, it will desensitize
the unit form approximately 7 minutes if a nuisance condition occurs. The alarm will chirp every 30-40 seconds during this time and will automatically reset after approximately 7 minutes and sound the alarm if particles of combustion
are still present. The Hush
®
feature shall be overridden and
the unit will alarm if the smoke is too dense.
The unit shall also include a low battery warning utilizing a brief alarm chirp every 30-40 seconds for a minimum
of seven (7) days.
The alarm will utilize a red LED that shall flash once every
30-40 seconds to indicate the alarm is receiving power.
Dual Sensor, Battery Operated
Smoke Alarm
Unit Number PI9000
Item Number 442007
Technical Specifications
Unit Number: PI9000
Item Number: 442007
UPC Number: 0-47871-42007-0
Power Source: 9V Battery
Sensor: Dual Ionization and Photoelectric
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range: 5%-95% relative humidity (RH)
Size: 5.75” in diameter x 1.8” depth
Weight: 1lb
Interconnects: No
LED: Red, normal operation
Warranty: 5 year limited
The unit shall at a minimum meet the requirements of
UL2034, UL217, NFPA72, (chapter 11, 2002 edition) The
State of California Fire Marshall, NFPA101 (One and two
family dwellings) Federal Housing Authority (FHA), Housing
and Urban Development (HUD). It shall also include a 5year manufacturer’s limited warranty.