Thank you for purchasing the Kidde
Combination Smoke and Carbon Monoxide Alarm
Model # KN-COSM-BCA.
This alarm has a five-year limited warranty.
Please take a few minutes to thoroughly read this
user’s guide, and save for future reference. Teach
children how to respond to the alarms, and that they
should never play with the unit.
Your Kidde Smoke/CO Alarm was designed to detect
both smoke and carbon monoxide from any source of
combustion in a residential environment. It is not
designed for use in a recreational vehicle (RV) or boat.
If you have any questions about the operation or
installation of your alarm, please call our toll free
Consumer Hotline at 1-800-880-6788.
The guide on page 25 will help you determine the
correct location of safety products that will help keep
your home a safer place.
1
I l l u s t r a t i o n
I l l u s t r a t i o n
FRONT
Test/Reset/
Hush®
Button
Alarm
Sounder
BACK
Red LED Light
Battery
Chamber
Green LED Light
Battery Placement
32
F e a t u r e s
F e a t u r e s
• Permanent independent smoke and carbon
monoxide sensors (ionization and electrochemical).
• Loud 85 decibel alarm.
• Alarm/Voice message warning system that specifies
which dangerous condition exists, eliminating any
confusion over which alarm is sounding:
FIRE: The alarm/voice pattern is 8 seconds of alarm
beeps followed by the verbal warning message,
“Fire! Feu!” This pattern is repeated until the smoke
is eliminated. The red LED light will flash while in
alarm/voice mode.
CARBON MONOXIDE: The alarm/voice pattern is four
short alarm beeps followed by the verbal warning
message, “Carbon Monoxide! Monox y d e de Carbone!”
This continues until the unit is reset or the CO
eliminated. After four minutes the alarm/voice
pattern will sound once every minute. The red
Light Emitting Diode (LED) light will flash while in
alarm/voice mode.
LOW BATTERY: When the batteries are low and need
replacing the red LED light will flash and the unit
will “chirp” one time, followed by the warn i n g
message, “ L o w Battery. P i l e Faible!” This cycle will
occur once every minute for the first hour. After
the first hour the red LED light will continue to flash
every minute accompanied by the "chirp" only
sound. The voice message “ L ow Battery. P i l eFaible!” will sound once every fifteen minutes
during the “chirp” only cycle. This will continue for
at least seven days.
• One “chirp” every 30 seconds is an indication that
the alarm is malfunctioning. If this occurs call the
Consumer Hotline at 1-800-880-6788.
NOTE: After seven (7) years of cumulative power up,
this unit will "chirp" every 30 seconds. This is an
"operational end of life" feature which will indicate
that it is time to replace the alarm.
• Oversized test button for easy activation.
• Test button performs the following functions:
Tests the units electronics and verifies
proper unit operation
Resets the unit during CO alarm
Activates HUSH® Feature (see Page 16).
Peak Level Memory (See Page 17).
• Mounting bracket designed for easy orientation
of unit.
• Green and red LED lights that indicate normal
operation and alarm status.
Green Light: The green Light Emitting Diode (LED)
flashes every 30 seconds to indicate the unit is
operating properly, and once every 2 seconds to
indicate the unit is in HUSH® mode. The green
light also flashes before a CO reading is taken and
when any button is pressed.
Red Light: When a dangerous level of smoke or
carbon monoxide is detected the red Light Emitting
Diode (LED) will flash and the corresponding alarm
pattern (depending on the source) will sound. If
the unit malfunctions, the red LED light will flash
and the unit will chirp every 30 seconds indicating a
system problem.
• Powered by three (3) AA batteries.
• Battery lockout system that prohibits installation
without using three batteries.
• Smoke alarm takes precedence when both smoke
and carbon monoxide are present.
54
F e a t u r e s
F e a t u r e s
TAMPER RESIST FEATURE
L o c a t i o n
of Posts
FIGURE 1A
A
A
FIGURE 1B
Tamper Resist Feature
To make the Smoke/CO alarm tamper resistant, a
tamper resist feature has been provided. Activate the
tamper resist feature by breaking off the four posts in
the square holes in the mounting plate (see Figure 1A).
Rotate the alarm onto the mounting plate until you
hear the tamper resist tab snap into place, locking the
alarm.
Using the tamper resist feature will help deter children
and others from removing the alarm. To remove the
alarm, press on the tamper resist tab, and rotate the
alarm off of the mounting plate (see Figure 1B).
Smoke Alarm
The smoke alarm constantly monitors the air for
products of combustion that are produced when
something is burning or smoldering. When smoke
particles in the smoke sensor reach a specified
concentration, the alarm/voice message warning system
will sound, accompanied by the flashing red LED light.
NOTE: The smoke alarm takes precedence when both
smoke and carbon monoxide are present.
This unit has a smoke sensor that uses the ionization
t e c h n o l o gy.
S m o ke alarms are devices that can provide early wa rning of
p o s s i b le fi r es at a re a s o n able cost,h o weve r, a l a rms have
sensing limitations.
I o n i z a t i o n sensing alarms may detect invisible fire particles
(associated with fast flaming fires) sooner than
photoelectric alarms.
P h o t o e l e c t ri c sensing alarms may detect visible fire particles
(associated with slow smoldering fires) sooner than
ionization alarms.
Home fi r es develop in diffe rent ways and are often
u n p r e d i c t abl e . For maximum pro t e c t i o n , Kidde re c o m m e n d s
both ionization and photoelectric smoke alarms be installed.
C AU T I O N : Smoke must reach the sensor to be detected.
Smoke alarms may not sense fires starting in chimneys,
walls, on roofs, on the other side of a closed door, or on a
d i ff e r ent floor. The alarm may be unable to wake a sound
s l e e p e r , or someone impaired by alcohol or drugs.