Kidde KN-COP-DP User Manual

AC Powered, Plug-In Carbon Monoxide Alarm
• Part Number 900-0056 • KN-COP-DP
Description
The Kidde 900-0056 is an AC powered, plug-in carbon monoxide alarm that can be installed easily in any stan­dard wall outlet. The 900-0056 uses advanced technolo­gy to monitor for carbon monoxide levels in your home and features a Nighthawk
TM
, electrochemical sensor, the world’s most accurate carbon monoxide sensing technology*. The digital display feature allows for easy viewing of carbon monoxide levels.
Consumer Benefits
The Kidde 900-0056 AC powered, plug-in carbon monoxide alarm provides you and your family a warning signal against the dangers of carbon monoxide levels in your home. This alarm is easily installed in any of your AC wall outlets. The digital display feature allows for easy viewing of carbon monoxide levels from 30-999PPM (parts per million). The 900-0056 is UL listed and offers a 5-year limited warranty.
Features and Benefits
• Digital Display – Displays the level of carbon monoxide
the unit is sensing. The unit updates this reading every 15 seconds.
• Peak Level Button – Displays the peak CO level
recorded by the alarm since it was last reset or unplugged.
•Test Button – Tests unit’s electronic circuitry and horn
and resets the unit during alarm.
*Based on accuracy claims of major manufacturers
NIGHTHAWK
TECHNOLOGY
World’s Most Accurate
Carbon Monoxide Alarm
*
TM
Digital Display
Displays the level of carbon monoxide the unit is sensing. The unit updates this reading every 15 seconds.
Test/Reset Button
Tests units electronic circuitry and horn and resets the unit during alarm.
Peak Level Button
Displays the peak CO level recorded by the alarm since it was last reset or unplugged.
NEW
FEATURE:
Alerts user to replace CO alarm after 7 years of operation
1394 South Third Street, Mebane NC 27302 1-800-880-6788 • www.kiddeus.com
AC Powered, Plug-In Carbon Monoxide Alarm
Part Number 900-0056 Unit Number KN-COP-DP
Architectural and Engineering Specifications
The carbon monoxide alarm shall be Kidde Unit Number KN-COP­DP (part number 900-0056) or approved equal. It shall be powered by a 120VAC, 60 Hz source. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity opera­tion range shall be 5% - 95% relative humidity.
The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL 2034 Single Station Carbon Monoxide Detectors. The unit shall provide accura­cy of +/-20% + 15 parts per million (ppm) when reading CO con­centration levels.
The alarm shall include an attached plug that can be installed in any outlet following the UL/NFPA/Manufacturer’s recommended guidelines. The plug shall be capable of being rotated so the alarm remains vertical independent of whether the electrical socket is mounted vertically or horizontally.
The unit shall incorporate a digital display that meets the sensi­tivity requirements of UL 2034. The display will identify the levels of CO in parts per million (ppm) once that level reaches 30ppm (i.e.: “abnormal” levels). The display will have a red dot in the lower right corner that will blink to indicate the normal operation.
The alarm shall include a test button that will electronically simulate the presence of CO and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation.
The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding level of CO.
The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. When the unit detects carbon monoxide, the alarm pattern will be four (4) short beeps – followed by five (5) seconds of silence – followed by four (4) short beeps. A number reading will appear on the digital display identifying the CO concentration (in ppm).
The unit shall include a peak level memory feature that will store the peak CO level sensed since the unit was last reset. The peak CO level stored in the unit’s memory shall be displayed (in ppm) on the digital display by pressing the appropriate button on the unit. The memory shall also be capable of being reset.
The unit shall be listed to UL 2034. It shall also include a 5-year manufacturer’s limited warranty.
Technical Specifications
Part Number: 900-0056 Unit Number: KN-COP-DP UPC Number: 7-84608-00560-1 Power Source: 120VAC Sensor: Electrochemical Audio Alarm: 85dB at 10ft Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C) Humidity Range: Up to 95% relative humidity (RH) Size: 5.65”L x 3.25”W x 1.9”H Weight: 1lb Interconnects: No Wiring: Plug-In LED: Displays CO concentration in PPM Warranty: 5 year limited
*Based on accuracy claims of major manufacturers
UNIT MASTER PACK CUT CASE POWER TOWER
1
PDQ
2
4
12
36
Ordering Information
Clam Shell UPC: 7-84908-00560-1
Part Dimensions Case/ Layers/ Skid Number I 2 of 5 Pack Quantity (w x d x h inches) Weight Skid Skid Weight
900-0056** N/A Individual 7 x 2.5 x 10.75 1lb N/A N/A N/A 900-0056-02 107 84908 00560 8 PDQ (2 units) 7.75 x 6 x 11.75 2lbs 105 3 210lbs 900-0056-07 207 84908 00560 5 Master Pack (4 units) 7.75 x 11.5 x 12 4lbs 80 4 320lbs 900-0056-012 307 84908 00560 2 Cut Case (12 units) 15 x 18 x 12 12lbs 18 3 216lbs 900-0056-036 407 84908 00560 9 Power Tower (36 units) 20 x 24 x 50 (incl. pallet) 36lbs 3 3 108lbs
**Not for sale by individual unit
3.25"
1.9"
5.65"
Distributed by: