Smoke Alarm
User’s Guide
Model: i9030, i9040, i9040RV i9050, i9060,
i9060RV and i9080
i9040
and
i9030
i9050
ATTENTION: Please take a few minutes to thoroughly read this
user’s guide which should be saved for future reference and
passed on to any subsequent owner.
Manual P/N 820-1493 Rev. A
i9060
and
i9060RV
• 9 Volt Battery Operated
i9040RV
i9080
What to do When the Alarm Sounds!
Smoke Alarm Procedure
NEVER IGNORE THE SOUND OF THE ALARM!
Smoke alarms are designed to minimize false alarms. Cigarette
smoke will not normally set off the alarm, unless the smoke is
blown directly into the alarm. Combustion particles from cooking may set off the alarm if it is located too close to the cooking area. Large quantities of combustion particles are generated from spills or when broiling. Using the fan on a range hood
which vents to the outside (non-recirculating type) will also
help remove these combustion particles from the kitchen.
If the alarm sounds, check for fires first. If a fire is discovered,
follow these steps. Become thoroughly familiar with these
steps and review with all family members:
• Alert small children in the home.
• Leave immediately by your escape plan. Every second
counts, so don’t waste time getting dressed or picking up
valuables.
• In leaving, don’t open any inside door without first feeling its
surface. If hot, or if you see smoke seeping through cracks,
don’t open that door! Instead, use your alternate exit. If the
inside of the door is cool, place your shoulder against it,
open it slightly and be ready to slam it shut if heat and
smoke rush in.
• If the air is smoky, stay close to the floor. Breathe shallowly
through a cloth, wet if possible.
• Once outside, go to your selected meeting place and make
sure everyone is there.
• Call the fire department from your neighbor’s home - not
from yours!
• Don’t return to your home until the fire officials say that it is
all right to do so.
Welcome
i9030, i9040, i9040RV, i9050, i9060, i9060RV, - 9 Volt Battery
Operated Smoke Alarm with “HUSH” Control to temporarily
silence nuisance alarms.
i9080 - 9 Volt Battery Operated Smoke Alarm with “HUSH”
Control to temporarily silence nuisance alarms and with Battery
Powered Safety Light.
Thank you for purchasing this smoke alarm. It is an important part
of your family’s home safety plan. You can trust this product to provide the highest quality safety protection. We know you expect
nothing less when the lives of your family are at stake.
Important Warning Statements
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION
AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE
REFERENCE.
WARNING: BATTERY DOOR WILL NOT CLOSE AND/OR ALARM
WILL NOT ATTACH TO MOUNTING BRACKET UNLESS BATTERY IS
INSTALLED CORRECTLY.
REMOVAL OF BATTERY WILL RENDER THE SMOKE ALARM
INOPERATIVE.
WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER RV OR
MOBILE HOME VEHICLE HAS BEEN IN STORAGE, BEFORE EACH
TRIP AND AT LEAST ONCE A WEEK DURING USE.
CAUTION: DUE TO THE LOUDNESS OF THE ALARM (85 DECIBELS),
ALWAYS STAND AN ARMS-LENGTH AWAY FROM THE UNIT WHEN
TESTING.
CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY
THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION
EXISTS. NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH
CONTROL FEATURE AND SOUND A CONTINUOUS ALARM.
SMOKE ALARMS ARE DEVICES THAT CAN PROVIDE EARLY WARNING OF POSSIBLE FIRES AT A REASONABLE COST; HOWEVER,
ALARMS HAVE SENSING LIMITATIONS. IONIZATION SENSING
ALARMS MA
WITH FAST FLAMING FIRES) SOONER THAN PHOTOELECTRIC
ALARMS. PHOTOELECTRIC SENSING ALARMS MAY DETECT VISIBLE
FIRE PARTICLES (ASSOCIATED WITH SLOW SMOLDERING FIRES)
SOONER THAN IONIZATION ALARMS. HOME FIRES DEVELOP IN
DIFFERENT WAYS AND ARE OFTEN UNPREDICTABLE. FOR MAXIMUM PROTECTION, KIDDE RECOMMENDS THAT BOTH
IONIZATION AND PHOTOELECTRIC ALARMS BE INSTALLED.
Y DETECT INVISIBLE FIRE PARTICLES (ASSOCIATED
Product Specifications
ANYWHERE ALONG
THIS BOLD SURFACE
12”
(300mm)
This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactive material (see section 9). Distributed under U.S. NRC License No. 32-23858-01E.
Manufactured in compliance with U.S. NRC safety criteria in 10 CFR
32.27. The purchaser is exempt from any regulatory requirements. Do
not try to repair the smoke alarm yourself. Refer to the instructions in
section 12 for service.
LOSS OF POWER TO THE ALARM WILL RENDER THIS ALARM
INOPERATIVE.
Contents of This User’s Guide
1. Recommended Locations for Smoke Alarms
2. Locations to avoid
3. Installation Instructions
4. Operation and testing
5. Nuisance Alarms
6. Maintenance
7. Limitations of Smoke Alarms
8. Good Safety Habits
9. NRC Information
10. NFPA Protection Standard 72
11. California State Fire Marshal Required Information
12. Service and Warranty
1. Recommended Locations for Smoke Alarms
• Locate the first alarm in the immediate
area of the sleeping rooms. Try to monitor
the exit path as the sleeping rooms are
usually farthest from the exit. If more than
one sleeping area exists, locate additional
alarms in each sleeping area (See figure 3).
• Locate additional alarms to monitor any
stairway as stairways act like chimneys for
smoke and heat.
• Locate at least one alarm on every floor
level.
• Locate an alarm in every sleeping room.
• Locate an alarm in every room where electrical appliances are operated (i.e. portable
heaters or humidifiers).
• Locate an alarm in every room where
someone sleeps with the door closed. The
closed door may prevent an alarm not
located in that room from waking the
sleeper.
• Smoke, heat, and combustion products
rise to the ceiling and spread horizontally.
Mounting the smoke alarm on the ceiling
in the center of the room places it closest
to all points in the room. Ceiling mounting is preferred in ordinary residential construction.
• For mobile home installation, select locations carefully to avoid thermal barriers
that may form at the ceiling. For more
details, see MOBILE HOME INSTALLATION
below.
• When mounting an alarm on the ceiling,
locate it at a minimum of 4” (10 cm) from
the side wall (see figure 1).
• When mounting the alarm on the wall, use
an inside wall with the top edge of the
alarm at a minimum of 4” (10 cm) and a
maximum of 12” (30.5 cm) below the ceiling (see figure 1).
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4