Agilent 70420A Installation Guide

Agilent Technologies E5500B Phase Noise Measurement System
Installation Guide
Part number: E5500-90002 PrintedinUSA June 2000 Supersedes April 1998 Manual Revision A.01.05
Notice
The information contained in this document is subject to change without notice.
Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Agilent Technologies assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Agilent Technologies.
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of Agilent Technologies.
U.S. Government Restricted Rights
The Software and documentation are provided with "Restricted Rights". Use, duplication or disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data andComputerSoftware clauses in DFARS 252.227-7013 or as set forth in subparagraph (c)(1) and (2) of the Commercial Computer Software ­Restricted Rights clauses at 48 CFR 52.227-19, as applicable. The Contractor for the Software is Agilent Technologies, 3000 Hanover Street, Palo Alto, California 94304.
Trademarks
Windows NT 4.0is a U.S trademarks of Microsoft Corp. Pentiumis a U.S. trademark of Intel Corporation
© Copyright Agilent Technologies 1997, 1998, 2000 Agilent Technologies
Santa Rosa Systems Division 1400 Fountaingrove Parkway Santa Rosa, CA 95403-1799, U.S.A.
Agilent Technologies E5500B Installation Guide
AGILENT TECHNOLOGIES SOFTWARE
The following terms govern your use of the enclosed software programs ("Software") unless you have a separate written agreement with Agilent Technologies.
LICENSE TERMS
License Grant
Agilent Technologies grants you a license to Use one copy of the version of the Software identified in your documentation on any one product. "Use" means storing, loading, installing, executing or displaying the Software. You may not modify the Software or disable any licensing or control features of the Software. Additional copies of the software may be used for the sole purpose of viewing previously measured data.
Ownership
The Software is owned and copyrighted by Agilent Technologiesor its third party licensors. Your license confers no title or ownership in the Software and should not be construed as a sale of any rights in the Software. Agilent Technologies' third party licensors may protect their rights in the event of any violation of these terms.
Copies and Adaptations
You may only make copies or adaptations of the Software for archival purposes or when copying or adaptation is an essential step in the authorized use of the software You must reproduce all copyright notices in the original Software on all authorized copies or adaptations. You may not copy the Software onto any bulletin board or similar system.
No Disassembly or Decryption
You may not disassemble, decompile or decrypt the Software unless Agilent Technologies' prior written consent is obtained. In some jurisdictions, Agilent Technologies' consent may not be required for disassembly or decompilation. Upon request, you will provide Agilent Technologies with reasonably detailed information regarding any disassembly or decompilation.
Transfer
Your license will automatically terminate upon any transfer of the Software. Upon transfer, you must deliver all copies of the Software and related documentation to the transferee. The transferee must accept these License Terms as a condition to the transfer.
Third Party Software
Software may include third party software. Those third parties m ay protect their rights in t he event of any violation of these License Terms.
Agilent Technologies E5500B Installation Guide
iii
Termination
Agilent Technologies may terminate your license upon notice for failure to comply with any of these License Terms. Upon termination, you must immediately destroy the Software, together with all copies, adaptations and merged portions in any form.
Export Requirements
You may not export or re-export the Software or any copy or adaptation in violation of any applicable laws or regulations.
iv
Agilent Technologies E5500B Installation Guide
What You’ll Find in This Manual…
Chapter 1 E5500B Installation
Agilent Technologies E5500B Installation Guide
v

Limited Warranty

Software AgilentTechnologieswarrants that the software will perform substantiallyin

accordance with the written materials for a period of one (1) year from the date of receipt.
Agilent Technologies does not warrant that the operation of the software will be uninterrupted or error free. In the event that this software product fails to execute its programming instructions during the warranty period, the customer’s remedy shall be to return the media to Agilent Technologies for replacement. Should Agilent Technologies be unable to replace the media within a reasonable amount of time, Customer’s alternate remedy shall be a refund of the purchase price upon return of all copies of the software.

Media Agilent Technologies warrants the media upon which this product is

recorded to be free from defects in materials and workmanship under normal use for a period of one (1) year from the date of purchase. In the event any media prove to be defective during the warranty period, Customer’s remedy shall be to return the media to Agilent Technologiesfor replacement. Should Agilent Technologies be unable to replace the media within a reasonable amount of time, Customer’s alternate remedy shall be a refund of the purchase price upon return of the product and all copies.

Notice of Warranty Claims

Limitation of Warranty

Customer shall notify Agilent Technologies in writing of any warranty claim not later than thirty (30) days after the expiration of the warranty period.
Agilent Technologies makes no other express warranty, whether written or oral, with respect to this product.
Any implied warranty of merchantability or fitness is limited to one (1) year duration of this written warranty.
This warranty gives specific legal rights, and Customer may also have rights which vary which vary from state to state, or province to province.
Exclusive Remedies The remedies provided above are Customer’s sole and exclusive remedies.
In no event shall Agilent Technologies be liable for any direct, indirect, special, incidental, or consequential damages (including lost profit) whether based on warranty, contract, tort, or any other legal theory.

Assistance For assistance, call your local Agilent TechnologiesSalesand Service Office

(refer to “Service and Support” on page -vii).
vi
Agilent Technologies E5500B Installation Guide

Service and Support

Any adjustment, maintenance, or repair of this product must be performed by qualified personnel. Contact your customer engineer through your local Agilent Technologies Service Center. You can find a list of Agilent Technologies Service Centers on the web at
http://www.agilent.com/find/tmdir.
If you do not have access to the Internet, one of these Agilent Technologies centers can direct you to your nearest Agilent Technologies representative:
United States: Agilent Technologies
Test and Measurement Call Center PO Box 4026 Englewood, CO 80155-4026 (800) 452 4844 (toll-free in US)
Canada: Agilent Technologies Canada Ltd.
5150 Spectrum Way Mississauga, Ontario L4W 5G1 (905) 206 4725
Europe: Agilent Technologies European Marketing Centre
Postbox 999 1180 AZ Amstelveen The Netherlands (31 20) 547 9900
Japan: Yokogawa-Agilent Technologies Ltd.
Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi Tokyo 192, Japan (81) 426 56 7832 (81) 426 56 7840 (FAX)
Latin America: Agilent Technologies Latin American Region
Headquarters 5200 Blue Lagoon Drive, 9th Floor Miami, Florida 33126, U.S.A. (305) 267 4245 (305) 267 4288 (FAX)
Australia/New Zealand:
Asia-Pacific: Agilent Technologies Asia Pacific Ltd.
Agilent Technologies Australia Ltd. 31-41 Joseph Street Blackburn, Victoria 3130 Australia 1 800 629 485 (toll-free)
17-21/F Shell Tower, Times Square 1 Matheson Street, Causeway Bay Hong Kong (852) 2599 7777 (852) 2506 9285 (FAX)
Agilent Technologies E5500B Installation Guide
vii
Notice.....................................................ii
AGILENTTECHNOLOGIESSOFTWARELICENSETERMS....iii
WhatYou’llFindinThisManual…..............................v
LimitedWarranty............................................vi
Software................................................vi
Media..................................................vi
NoticeofWarrantyClaims..................................vi
LimitationofWarranty.....................................vi
ExclusiveRemedies.......................................vi
Assistance...............................................vi
ServiceandSupport.........................................vii
1. WelcometotheE5500BPhaseNoiseMeasurementSystemSeriesof Solutions
WhatYou’llFindinThisChapter................................1-1
Introduction................................................1-3
SystemRequirements........................................1-4
Step1.UnpackingYourSystem................................1-5
Step2.InstallingtheHardware.................................1-6
Step2a-RemovingyourComputer’sCover...................1-7
Step2b-AccessingyourComputer’sISASlots................1-8
Step2c-TakingESDPrecautions...........................1-9
Step2d-InstallingtheInterfaceCards.......................1-10
Step2e-ReplacingtheComputerCover.....................1-13
Step3.InstallingtheI/OLibraries.............................1-16
Step3a-InstallingtheAgilent/HPI/OLibraries...............1-16
Step3b-InstallingtheAgilent/HPI/OLibraryUpgrade........1-17
Step4.InstallingthePC-DigitizerSoftware.....................1-19
Step5.InstallingtheWindowsNT4.0ServicePack...............1-20
Step6.InstallingtheMeasurementSoftware.....................1-22
Step7.UsingtheAssetManagertoConfigureyourSystem.........1-23
DefaultGPIBAddresses.................................1-32
Step8.EnteringtheLicenseKeyforthePhaseNoiseTestSet.......1-33
Step9.StartingtheMeasurementSoftware......................1-36
Step10.UsingServerHardwareConnectionstoSpecifyAssetsforthe
ConfidenceTest........................................1-37
Step11.RunningtheSoftwareConfidenceTest..................1-39
BeginningtheMeasurement...............................1-41
MakingtheMeasurement.................................1-42
Congratulations........................................1-42
Agilent Technologies E5500B Installation Guide
Contents-1
1 Welcome to the E5500B Phase Noise
Measurement System Series of Solutions
Agilent Technologies E5500B Installation Guide
1-1
Welcome to the E5500B Phase Noise Measurement System Series of Solutions

What You’ll Find in This Chapter...

“Introduction” on page 1-3
“System Requirements” on page 1-4
“Step 1. Unpacking Your System” on page 1-5
“Step 2. Installing the Hardware” on page 1-6
“Step 3. Installing the I/O Libraries” on page 1-16
“Step 4. Installing the PC-Digitizer Software” on page 1-19
“Step 5. Installing the Windows NT 4.0
Service Pack” on page 1-20
“Step 6. Installing the Measurement Software” on page 1-22
“Step 7. Using the Asset Manager to Configure your System” on page
1-23
“Step 8. Entering the License Key for the Phase Noise Test Set” on page
1-33
“Step 9. Starting the Measurement Software” on page 1-36
“Step 10. Using Server Hardware Connections to Specify Assets for the
Confidence Test” on page 1-37
“Step 11. Running the Software Confidence Test” on page 1-39
1-2
Agilent Technologies E5500B Installation Guide
Welcome to the E5500B Phase Noise Measurement System Series of
Solutions

Introduction

This installation guide will take you though the process of installing both the hardware (if you did not order a preconfigured system from Agilent Technologies) and the E5500 Phase Noise Software. A confidence test is also included as the last step in the installation procedure.
Table 1 Installation Steps
If you ordered a preconfigured system, do these steps:
Skip “System Requirements” on page 1-4 Read “System Requirements” on page 1-4
“Step 1. Unpacking Your System” on page 1-5 “Step 1. Unpacking Your System” on page 1-5
Skip Steps 2 to 8 “Step 2. Installing the Hardware” on page 1 -6
“Step9. Starting the Measurement Software” on page 1-36
“Step 10. Using Server Hardware Connections to Specify Assets for the Confidence Test” on page 1-37
If you ordered an Option 1FF (delete computer), do these steps:
“Step3. Installing the I/O Libraries” on page 1-16 “Step 4. Installing the PC-Digitizer Software” on page 1-19
“Step5. Installing the Windows NT 4.0 page 1-20
“Step6. Installing the Measurement Software” on page 1-22 “Step7.UsingtheAssetManagertoConfigureyourSystem”
on page 1-23 “Step8. Entering the License Key for the Phase Noise Test
Set” on page 1-33 “Step9. Starting the Measurement Software” on page 1-36
“Step10. Using Server Hardware Connections to Specify Assets for the Confidence Test” on page 1-37
Service Pack” on
“Step11. Runningthe Software ConfidenceTest” on page 1-39
“Step11. Running the Software Confidence Test” on page 1-39
Agilent Technologies E5500B Installation Guide
1-3
Welcome to the E5500B Phase Noise Measurement System Series of Solutions

System Requirements

The setup program in the E5500 Phase Noise Measurement Software makes installation easy. In case you want a quick review of the system requirements, we have listed them first.
The system requirements for the phase noise measurement software are:
Pentium
microprocessor (100 MHz or higher recommended)
32 megabytes (MB) of memory (RAM)
1 gigabyte (GB) hard disk
Super Video Graphics Array (SVGA)
2 additional 16-bit ISA slots available for the phase noise system
hardware.
1 for PC-Digitizer 1 for GPIB Interface Card
Windows NT 4.0
Windows NT 4.0 Service Pack 4 or greater
IEEE-488 GPIB I nterface Card (Agilent/HP 82341C GPIB Interface
Card)
1-4
Agilent Technologies E5500B Installation Guide
Welcome to the E5500B Phase Noise Measurement System Series of
Solutions

Step 1. Unpacking Your System

1. Unpack and inspect the shipping container and its contents thoroughly to ensure that nothing was damaged during shipment.
If the container or packing material is damaged, the contents should be checked both mechanically and electrically.If the contents are damaged or defective, contact your nearest Agilent Technologies Sales and Service office. Keep the shipping materials for the carrier’s inspection.
2. Verify that all parts and materials were included in the shipping container:
E5500 Phase Noise Measurement System CD-ROM
E5500 Software Keyword Licence Certificate
E5500 User’s Guide
E5500B Installation Guide
9300-1408 Disposable Grounding Strap (Option 1FF)
5957-4369 Electrostatic Discharge (ESD) Warning Pamphlet
PC-Digitizer Card (Option 1FF)
Table 1-2 Connectors and Adapters
Part Number Description
1250-0207 BNC, 50 ohm Termination 1 1 1 1250-0780Adapter,N(m)-BMC(f) 3231 1250-1250 Adapter,N(m) - SMA(f) 1 2 1250-2015 Adapter,SMA(f) - BNC(m) 1 5061-5311 Adapter/Saver, 3.5mm(f) - 3.5mm(f) 2 2 1250-1200 Adapter,SMA(m) - BNC(f) 2
Agilent/HP
70420A
Agilent/HP
70420A
Option 001
Agilent/HP
70420A
Option 201
Agilent/HP
70422A
Agilent Technologies E5500B Installation Guide
1-5
Welcome to the E5500B Phase Noise Measurement System Series of Solutions

Step 2. Installing the Hardware

NOTE If you have ordered a preconfigured phase noise system from Agilent
Technologies, skip this step and proceed to “Step 9. Starting the
Measurement Software” on page 1-36.
Installing the phase noise hardware into your computer involves the following steps:
“Step 2a - Removing your Computer’s Cover” on page 1-7 “Step 2b - Accessing your Computer’s ISA Slots” on page 1-8 “Step 2c - Taking ESD Precautions” on page 1-9 “Step 2d- Installing the Interface Cards” on page 1-10 “Step 2e - Replacing the Computer Cover” on page 1-13
1-6
Agilent Technologies E5500B Installation Guide
Welcome to the E5500B Phase Noise Measurement System Series of
Solutions

Step 2a - Removing your Computer’s Cover

CAUTION Refer to your computer’s documentation for installation safety instructions
and specific instructions for opening your computer.
Use the following steps to install the GPIB and PC-Digitizer cards in your computer:
3. Power down the computer and all its peripherals.
4. Disconnect the power cord from the computer.
5. Unlock and remove the cover from the computer. This gives access to the I/O slots. (See your computer documentation for detailed instructions.)
Agilent Technologies E5500B Installation Guide
1-7
Welcome to the E5500B Phase Noise Measurement System Series of Solutions

Step 2b - Accessing your Computer’s ISA Slots

6. Look for suitable ISA expansion slots for both the GPIB and PC-Digitizer cards and remove the back panel’s cover plates. Choose slots that give good access to the GPIB and PC-Digitizer connectors.
The following drawing shows a view of the ISA slots vertically mounted; your computer’s ISA slots may be horizontally mounted, but the process is the same.
1-8
Agilent Technologies E5500B Installation Guide