Agilent 54602B Data Sheet

Analog feel and digital power for precise, accurate troubleshooting at an affordable price
With many models to choose from, you will be able to pick the oscilloscope that best fits your meas­urement and troubleshooting needs while meeting your budget.
Displays you can trust
The multiprocessor architecture of Agilent 54600­series oscilloscopes permits a display update rate of up to 3.0 million points per second. This fast display update means the oscilloscope screen reflects changes in the waveform instantaneously, giving you the display responsiveness you need to make adjustments quickly and see complex waveforms accurately.
Powerful digital features
The digital architecture of Agilent 54600-series oscilloscopes gives you a multitude of features that help you get your job done easier and faster:
• Pretrigger viewing capability lets you view events that you’d miss with an analog scope. This feature lets you see what happened before the trigger event, so you can troubleshoot more effectively.
• Autoscale frees you from resetting the scope every time you move the probe from test point to test point. You simply hit the autoscale button and it sets voltage, time and trigger parameters for you.
• With autostore, the waveform displays at full brightness while all previously acquired wave­forms remain on the scope’s screen at half bright­ness. You see a history of waveform activity while simultaneously viewing the live waveform.
• Automatic measurements of voltage, frequency and time, plus user-defined cursor measurements, make waveform characterization fast and easy.
• With peak detect, you won’t have to worry about missing narrow glitches.
Agilent 54600-Series Oscilloscopes
Data Sheet
• 60/100/150/500 MHz bandwidth models with 2 or 4 channels
• Easy-to-use analog front panel
• Fast, responsive display
• Automatic measurements
• Pretrigger viewing, trace storage
• Optional remote control/hard copy
2
The Agilent 54600 series includes eight models designed to meet your needs and your budget:
54600B 100 MHz oscilloscope
With 100 MHz bandwidth, two input channels, and sweep speeds from 2 ns/div to 5 ns/div, the 54600B is ideal for benchtop troubleshooting, production test, field service, and education— or anywhere else you need a dependable scope with solid performance.
54645A MegaZoom oscilloscope
The 54645A is a dual-channel 100 MHz oscilloscope with 200 MSa/s and a full 1 MB of memory behind each of its channels. Through the application of MegaZoom technology, accessing this deep-memory is as easy as turning a knob—pan and zoom through the deep captured waveform to search for other troubleshooting clues.
54602B 4 (2 + 2)-channel oscilloscope
When you need more than 100 MHz of bandwidth, take a closer look at the 54602B scope. You get the same capabilities as the 54600B but with the added advantage of a 150 MHz bandwidth, 4 (2+2) channels, and 1 mV/div sensitivity.
54603B 60 MHz oscilloscope
The 54603B was designed with the tight budgets of colleges and universities in mind. Students can use the 60 MHz, 2-channel 54603B to understand circuit operation and learn standard measurement techniques on the same type of equipment they are likely to use when they graduate.
54610B 500 MHz oscilloscope
This lowest-cost, 2-channel 500 MHz scope offers a viewable external trigger and horizontal accuracy of 0.001%. The 54610B capabilities are well-suited for production test applications as well as general purpose troubleshooting.
54615B 1 GSa/s oscilloscope
With the 54615B you can capture narrow glitches and subtle details of your signal. This 2-channel scope combines 500 MHz bandwidth, 1 GSa/s sam­ple rate and 1 nanosecond peak detection on both channels. The 54615B peak detection allows the scope to maintain the 1 GSa/s sample rate at all sweep speeds. A horizontal accuracy of 0.005% means you can make critical timing measurements with confidence.
54616B/C 2 GSa/s oscilloscope
The top-of-the-line 54616B offers the same benefits as the 54615B but with twice the sample rate— 2 GSa/s sampling rate, 500 MHz bandwidth, and 1 nanosecond peak detection. Plus, if you prefer a color display for waveform viewing, the 54616C color version is available.
Expandable features to meet your changing needs
The Agilent 54600-series oscilloscopes can be easily and inexpensively upgraded with add-on modules and software to provide advanced capabilities:
• Interface modules give you remote control and hard-copy output to RS-232, GPIB, and parallel printers and plotters.
• Measurement Storage modules offer interfacing and printing plus advanced features like FFT, mask testing, and additional memory.
• Agilent BenchLink XL 54600 free software cap­tures screen images, gathers waveform data, and stores instrument setups, all from the famil­iar environment of MS Excel or Word. Ships free with each module.
• Optional Agilent BenchLink Scope is a stand­alone software package for bringing waveform images and points into your PC. Use it when you need Windows 3.1 compatibility, don’t have Excel or Word, or need to access trace memory from your PC.
Enhanced TV/video trigger
With Option 005 you gain the ability to trigger and perform highly detailed measurements on the video components of your system. For more information see Agilent publication number 5968-2611. Not available on the 54600B, 54603B, or 54645D scopes.
3
Technical Specifications
54603B 54600B 54645A 54602B 54610B 54615B/16B/16C
Bandwidth
CH 1 and 2 dc-60 MHz dc-100 MHz dc-100 MHz
††
dc-150 MHz* dc-500 MHz dc-500 MHz
ac coupled 10 Hz-60 MHz 10 Hz-100 MHz 1.5 Hz-100 MHz††10 Hz-150 MHz* 10 Hz-500 MHz 10 Hz-500 MHz
CH 3 and 4 NA NA NA dc-250 MHz NA NA
Single shot bandwidth dc-2 MHz dc-2 MHz dc-50 MHz dc-2 MHz dc-2 MHz 54615B 250 MHz
54616B/C 500 MHz
Number of channels 2224 (2+2) 2 2
Sensitivity
CH 1 and 2 2 mV/div to 5 V/div 2 mV/div to 5 V/div 1 mV/div to 5 V/div 1 mV/div to 5 V/div 2 mV/div to 5 V/div 2 mV/div to 5 V/div CH 3 and 4 NA NA NA 0.1 and 0.5 V/div NA NA
dc gain accuracy ± 2% ± 1.5% ± 1.5% ± 1.5% ± 2% ± 2%
Rise time (calculated)
CH 1 and 2 <5.83 ns <3.5 ns <3.5 ns <2.33 ns <700 ps <700 ps CH 3 and 4 NA NA NA <1.4 ns NA NA
Input impedance 1 M, ~ 13 pF 1 M, ~ 18 pF 1 M, ~ 13 pF 1 M, ~ 13 pF 1 M, ~ 9 pF 1 M, ~ 9 pF
or 50 selectable or 50 selectable
Input coupling
CH 1 and 2 dc, ac or ground dc, ac or ground dc, ac or ground dc, ac or ground dc, ac or ground dc, ac or ground CH 3 and 4 NA NA NA dc or ground NA NA
Maximum input 400 V 400 V 400 V 400 V 250 V or 5 Vrms 250 V or 5 Vrms
(dc + peak ac) in 50 mode in 50 mode
Timebase range 5 s/div to 5 ns/div 5 s/div to 2 ns/div 5 s/div to 2 ns/div 5 s/div to 2 ns/div 5 s/div to 1 ns/div 5 s/div to 1 ns/div (main and delayed)
Trigger sources CH 1, 2, line, or ext. CH 1, 2, line, or ext. CH 1, 2, line, or ext. CH 1, 2, 3, 4, line CH 1, 2, line, or ext. CH 1, 2, line, or ext.
Horizontal accuracy ± 0.01% ± 0.01% ± 0.01% ± 0.01% ± 0.01% ±0.005%
Horizontal resolution 100 ps 100 ps 40 ps 100 ps 100 ps 20 ps
Trigger sensitivity
dc to 25 MHz 0.35 div or 3.5 mV 0.35 div or 3.5 mV 0.35 div or 3.5 mV 0.35 div or 3.5 mV 0.35 div or 3.5 mV 0.5 div or 5.0 mV*** 25 MHz to max. 1 div or 10 mV 1 div or 10 mV 1 div or 10 mV 1 div or 2 mV** 1 div or 10 mV
1 div or 10 mV
bandwidth
Maximum sample rate
single shot 20 MSa/s 20 MSa/s 200 MSa/s 20 MSa/s 20 MSa/s 54615 1 GSa/s
54616 2 GSa/s
repetitive 10 GSa/s 10 GSa/s >10 GSa/s 10 GSa/s 10 GSa/s >10 GSa/s
Record length 4,000 points 4,000 points 1M points 4,000 points 4,000 points 5,000 points
2,000 points 2,000 points 1M points 2,000 points 2,000 points 5,000 points
Max. display update rate 1,500,000 points/sec 1,500,000 points/sec 3,000,000 points/sec 1,500,000 points/sec 1,500,000 points/sec 500,000 points/sec
Resolution 8 bits
Power Voltage: 100-240 Vac, 45 to 440 Hz, 220 VA maximum
Net weight Approx. 6.2 kg (14 lbs)
Size (excl. handle) 172 mm H x 322 mm W x 317 mm D (6.8 x 12.7 x 12.5 in)
Warranty 3 years
* Maximum bandwidth on CH 1 and 2 is 100 MHz at 1, 2, and 5 mV/div. ** 64602B, for ranges 1, 2, and 5 mV/div, sensitivity between
25 MHz and 100 MHz on CH 1 and 2 is 2 div or 4 mV. *** Trigger sensitivity from dc to 100 MHz. † Trigger sensitivity from 100 MHz to max. bandwidth. †† Maximum bandwidth on CH 1 and 2 is 75 MHz at 1, 2 and 5 mV/div.
Loading...