Keysight 11904S User Guide

Keysight 11904S
2.4 mm/2.92 mm Adapter Set
User’s and Service Guide
Notices
CAUTION
WARNING
Copyright Notice
© Keysight Technologies 2012 - 2019 No part of this manual may be reproduced in
any form or by any means (including electronic storage and retrieval or translation into a for­eign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws.
Manual Part Number
11904-90009
Edition
Edition 6, February 20, 2019
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies Bayan Lepas Free Industrial Zone, 11900 Penang, Malaysia
Technology Licenses
The hard ware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product and for other Keysight products may be down­loaded from the Web. Go to http://www.key-
sight.com/go/conformity. You can then search
by product number to find the latest Declara­tion of Conformity.
U.S. Government Rights
The Software is “commercial computer soft­ware,” as defined by Federal Acquisition Regu­lation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.key-
sight.com/find/sweula. The license set forth in
the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documenta­tion that is not customarily provided to the public; or (2) Relinquish to, or otherwise pro­vide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, d is­play, or disclose commercial computer soft­ware or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial com­puter software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or other­wise modify the Software. With respect to any technical data as defined by FAR 2.101, pursu­ant to FAR 12.211 and 27.404.2 and DFARS
227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as applicable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS DOCU­MENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXI­MUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRAN­TIES, EITHER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFOR­MATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRAN­TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCU­MENT OR OF ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CON­FLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not pro­ceed beyond a CAUTION notice until the indi­cated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
2 Keysight 11904S User’s and Service Guide

Certification

Keysight Technologies certifies that this product met its published specifications at the time of shipment from the factory. Keysight Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (NIST, formerly NBS), to the extend allowed by the Institute’s calibration facility, and to the calibration facilities of the other International Standards Organization members.

Regulatory Markings

The CE mark is a registered trademark of the European Community. This CE mark shows that the product complies with all the relevant European Legal Directives.
The CSA mark is a registered trademark of the Canadian Standards Association.
ICES/NMB-001 indicates that this ISM device complies with the Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada.
This symbol indicates the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use. Forty years is the expected useful life of the product.
This text indicates that the instrument is an Industrial Scientific and Medical Group 1 Class A product (CISPER 11, Clause 4).
Keysight 11904S User’s and Service Guide 3

Waste Electrical and Electronic Equipment (WEEE) Directive

This instrument complies with the WEEE Directive marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.

Product category:

With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://
about.keysight.com/en/companyinfo/environment/takeback.shtml for more information.

Sales and Technical Support

To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites:
www.keysight.com/find/adapters
(product-specific information and support, software and documentation updates)
www.keysight.com/find/assist
(worldwide contact information for repair and service)
4 Keysight 11904S User’s and Service Guide

Table of Contents

Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Regulatory Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Waste Electrical and Electronic Equipment (WEEE) Directive . . . . . . . . . . . . . . . . . . . . 4
Product category: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 General Information
Adapter Set Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Adapter set contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Calibration definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Adapters (2.4 mm and 2.92 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connector adapter sets documented in this manual . . . . . . . . . . . . . . . . . . . . . . . . 12
Equipment required but not supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Incoming Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Clarifying the Sex of Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 Specifications
Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Temperature — what to watch out for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Mechanical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Pin depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Residual errors after calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3 Use, Maintenance, and Care of the Devices
Electrostatic Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Visual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Look for obvious defects and damage first . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
What causes connector wear? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Inspect the mating plane surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Slotted connectors (2.92 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Precision slotless connectors (2.4 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Calibration Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Full two-port calibration overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Two-port calibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Cleaning the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Keysight 11904S User’s and Service Guide 5
Gaging Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Connector gage accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
When to gage connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Gaging Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Gaging 2.4 mm and 2.92 mm connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
How to make a connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Final connection using a torque wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
How to separate a connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Operational Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Connect the 2.4 mm lowband load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Handling and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4 Performance Verification
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
How Keysight Verifies the Devices in Your Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
How often to recertify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Where to send a kit for recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
5 Troubleshooting
Troubleshooting Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Returning a Kit or Device to Keysight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Where to look for more information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
How Keysight Verifies the Devices in Your Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
How often to recertify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Where to send a kit for recertification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6 Keysight 11904S User’s and Service Guide

List of Figures

Figure 2-1 Connector pin depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 3-1 ESD protection setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 3-2 Full two-port calibration - Keysight 8510 VNA using calibration kit defini-
Figure 3-3 Gaging 2.4 mm and 2.92 mm connectors . . . . . . . . . . . . . . . . . . . . . . 35
Figure 3-4 Wrench positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 3-5 Using the torque wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 3-6 2.4 mm to 2.92 mm adapter to lowband load . . . . . . . . . . . . . . . . . . . 39
Figure 3-7 2.4 mm to 2.92 mm adapter to sliding load . . . . . . . . . . . . . . . . . . . . 41
Figure 5-1 Troubleshooting flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
tion CK_292MMA3 and higher . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Keysight 11904S User’s and Service Guide 7
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
8 Keysight 11904S User’s and Service Guide

List of Tables

Table 1-1 Clarifying the sex of connectors: examples . . . . . . . . . . . . . . . . . . . . . 14
Table 2-1 Environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 2-2 Pin depth limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 2-3 Electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 3-1 Torque wrench information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Keysight 11904S User’s and Service Guide 9
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
10 Keysight 11904S User’s and Service Guide
Keysight 11904S 2.4 mm/2.92 mm Adapter Set User’s and Service Guide

1 General Information

Adapter Set Overview 12 Incoming Inspection 13 Clarifying the Sex of Connectors 14 Preventive Maintenance 15
This chapter provides you with an overview of the 11904S adapter set.
11
1 General Information

Adapter Set Overview

The Keysight 11904S adapter set is designed to give network analyzer systems with 2.4 mm test ports (such as the Keysight 8510, 8722, and the PNA Series) the ability to perform measurements on devices with 2.92 mm connectors. The set can be used to achieve calibrated measurements of
2.92 mm devices up to 40 GHz, and 2.4 mm devices up to 50 GHz.

Adapter set contents

The basic 11904S adapter set includes the following items:
– User’s and Service Guide (x 1)
– 2.4 mm to 2.92 mm adapters (x 4)
– 5/16 in, 56 N-cm (5 in-lb) torque wrench for use on the 2.92 mm connectors (x 1)
– Open-end wrench for the 7 mm flats on some of the components (x 1)

Calibration definitions

The calibration definitions are for you to use with your analyzer. Refer to your network analyzer User’s Guide, or embedded Help for information on modifying the calibration kit standard definitions.
8510
– 2.92 mm A.3, contains modified standards data to account for the adapters, which are inserted
after a 2.4 mm calibration is performed.
– 2.4 mm A.4, contains calibration definitions for only the 2.4 mm devices.

Adapters (2.4 mm and 2.92 mm)

Like the other devices in the kit, the adapters are built to very tight tolerances to provide good broadband performance and to ensure stable, repeatable connections.
The adapters are designed so that their nominal electrical lengths are the same, which allows them to be used in calibration procedures for non-insertable devices (such as adapter removal).
The male 2.4 mm and 2.92 mm connectors are metrology grade. The female PSC-2.4 mm is a metrology–grade, precision slotless connector. The female 2.92 mm connectors have slotted contacts and therefore cannot be considered metrology grade. Due to the extremely thin wall of the 2.92 mm female connector, a slotless metrology grade 2.92 mm connector pair does not currently exist.

Connector adapter sets documented in this manual

The part numbers provided in this manual are the recommended replacement parts for this set. The devices in this set should meet the specifications published in this manual.

Equipment required but not supplied

Some items are required or recommended for successful operation of your kit, but are not supplied with the kit.
12 Keysight 11904S User’s and Service Guide

Incoming Inspection

To verify the electrical performance of the devices in this set, see Chapter 4, "Performance
Verification".
Check for damage. The foam-lined storage case provides protection during shipping. If the case or any device appears damaged, or if the shipment is incomplete, refer to the Keysight contact numbers located at the end of this manual. Keysight will arrange for repair or replacement of incomplete or damaged shipments without waiting for a settlement from the transportation company. See “Returning a Kit or Device to Keysight” on page 49.
General Information 1
Keysight 11904S User’s and Service Guide 13
1 General Information

Clarifying the Sex of Connectors

In this document and in the prompts of the PNA calibration wizard, the sex of cable connectors and adapters is referred to in terms of the center conductor. For example, a connector or device designated as 1.85 mm –f– has a 1.85 mm female center conductor.
8510-Series, 872x, and 875x ONLY: In contrast, during a measurement calibration, the network analyzer softkey menus label a 1.85 mm calibration device with reference to the sex of the analyzer’s test port connector—not the calibration device connector. For example, the label SHORT(F) refers to the short that is to be connected to the female test port. This will be a male short from the calibration kit.
Tab le 1-1 Clarifying the sex of connectors: examples
Terminology Meaning
Short –f– Female short (female center conductor)
Short (f) Male short (male center conductor) to be connected to female port
A connector gage is referred to in terms of the connector that it measures. For instance, a male connector gage has a female connector on the gage so that it can measure male devices.
14 Keysight 11904S User’s and Service Guide

Preventive Maintenance

The best techniques for maintaining the integrity of the devices in the kit include:
– routine visual inspection
– routine cleaning
– proper gaging
– proper connection techniques
All of these are described in Chapter 3, "Use, Maintenance, and Care of the Devices". Failure to detect and remove dirt or metallic particles on a mating plane surface can degrade repeatability and accuracy and can damage any connector mated to it. Improper connections, resulting from pin depth values being out of the observed limits (see Table 2-2 on page 20) or from bad connection techniques, can also damage these devices.
General Information 1
Keysight 11904S User’s and Service Guide 15
1 General Information
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
16 Keysight 11904S User’s and Service Guide
Loading...
+ 37 hidden pages