Kerui Smart Technology KR RC531, KR P829, KR G19, KR D026 User Manual

Table of Contents
Chapter One System Introduction .............................................................................................................................. 2
Chapter Two Function Features ..................................................................................................................................... 2
Chapter Three Host Installation ..................................................................................................................................... 3
Chapter Four Operation&Setting .................................................................................................................................. 4
4.1 Initial Power-on ..................................................................................................................................................... 4
4.2 Arm ......................................................................................................................................................................... 4
4.3 Disarm .................................................................................................................................................................... 4
4.4 Stay Arm ................................................................................................................................................................ 4
4.5 Accessories Management ...................................................................................................................................... 4
4.6. Remote Control .................................................................................................................................................... 5
4.6.1 Study Remote Control ................................................................................................................................ 5
4.6.2 Delete Remote Control ............................................................................................................................... 5
4.7 Detector .................................................................................................................................................................. 6
4.7.1 Study Detectors ........................................................................................................................................... 6
4.7.2 Delete Detectors .......................................................................................................................................... 6
4.7.3 Call Alarm ON/OFF ................................................................................................................................... 6
4.7.4 Zone Attribute ............................................................................................................................................ 7
4.7.5 Network Event Code .................................................................................................................................. 7
4.7.6 NO alarm/NC alarm in Wired Zone ......................................................................................................... 7
4.8 Access Card ............................................................................................................................................................ 7
4.8.1 Study Access Card ...................................................................................................................................... 7
4.8.2 Delete Access Cards .................................................................................................................................... 8
4.9 Wireless Strobe Siren ............................................................................................................................................ 8
4.9.1 Code Match between Host & Wireless Strobe Siren ............................................................................... 8
4.9.2 Alarm Siren ................................................................................................................................................. 9
4.10 Wireless Alarm Linkage Switch ......................................................................................................................... 9
4.10.1 Code Match between Host and Smart Socket ........................................................................................ 9
4.10.2 Alarm Linkage ........................................................................................................................................ 10
Chapter Five Installation and Usage of Detectors ................................................................................................... 10
5.1 Installation and Use of Door Sensor ............................................................................................................... 10
5.2 Installation and Use of PIR Motion Detector ................................................................................................... 12
Chapter Six Troubleshooting ...................................................................................................................................... 13
Chapter One System Introduction
This alarm system with stable and reliable performance and applies 2.4-inch TFT color screen and touch keyboard with
smoke detectors, gas detectors and emergency button accessories etc. After receiving an alarm, host will display the
alarm zone and alarm siren on site, It’s widely used in houses, factories, schools, shops, convenience stores, financial
Chapter Two Function Features
■ TFT color display, humanized menu, operation with voice prompt, easy to use
■ Read RFID (125KHz) card to disarm, can learn 20 cards.
■ There are 99 zones and 8 zone types optional in each zone; ON/OFF siren in each zone is available.
■ 2 wired zones, Open and Closed Alarm mode optional
Host can be used as a normal cellphone to call other phones directly
■ APP control host set and administration, and supports IOS/Android.
■ 8 groups scheduling Arm/Disarm function, and date can be selected to avoid arm and disarm frequently manually
to realize automatic control.
■ One-way alarm linkage wireless relay, and one-way wireless strobe siren
■ 10s automatic message recording with built-in artificial voice, so that user can know the alarm place and zone
when receive the alarm call remotely.
■ Arm/Disarm, Monitor, Speaker, siren ON/OFF, relay ON/OFF remotely.
■ Wireless study 1527 series accessories, and as much as 99 detectors and remote controls.
■ Integrate high precision clock chip so that time never lost even power failure.
■ Display the latest 99 arm/disarm, alarm and card read records with unique black box function.
■ Low-voltage indication and anti-tamper
■ Built-in rechargeable high capacity LI battery and supply power automatically when power supply failure
■ Caller ID display, power-off reminder.
Chapter Three Host Installation
Host should be installed in the central position of the guard area to receive the signals from detectors best. Keep away
and fire doors barriers etc.
Chapter Four Operation&Setting
4.1 Initial Power-on
According to the installation method put the output of the powered adapter in the power supply hole of the host.
Now then, host voice prompts “ Welcome to smart voice alarm”, and switch the back-up battery to the ON state.
4.2 Arm
Arm refers to a full range of on-site alarm detection alert when nobody at home; All detectors are in working state,
when there is danger ( theft, fire, gas leak etc ) trigger the detectors, the host alarms immediately. After arming operation,
it displays and locks “arm” icon.
Remote Control operation: press key [ARM] once.
Keyboard operation: press key [ARM] once.
4.3 Disarm
Disarm refers to host panel stops the alarm or make the alarm system in a non-alert state. After disarming, when
detectors are triggered, but host doesn’t alarm (except the detectors of emergency zones and the emergency button on
remote control). After disarming operation, it displays and locks “disarm” icon.
Remote Control operation: press key [Disarm].
Keyboard operation: press key [Disarm].
4.4 Stay Arm
STAY refers to when someone at home, and for safety, the detectors in the perimeter area like doors, windows,
balconies are in working state but the detectors indoor don’t work in case of the false alarm if triggered by user himself,
then the user chooses STAY to let some detectors work and other detectors not work. STAY function needs to be set that
is the defense zones of the interior detectors should be changed to be stay zones in order to work properly. After STAY
operation, it displays and locks “STAY” icon.
Remote Control operation: press key [STAY].
Keyboard operation: press key [ARM] twice
4.5 Accessories Management
As shown in picture 4-2, press keyUP/DOWNto move cursor to Accessories Manage icon, then press keyOKor
input number 2 to enter accessories manage page, as shown in picture 4-7.
Loading...