KERN & SOHN MFB 150K100 User Manual

KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com
Body fat balance
KERN MFB
Version 1.0 08/2008 GB
Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com
MFB -BA-e-0810
E
KERN MFB 150K100
Version 1.0 08/2008
Operating Manual
Table of Contents
1 Technical Data__________________________________________________ 3 2 Basic Information (General)_______________________________________ 4
1.0 Proper use_______________________________________________________ 4
2.0 Improper Use ____________________________________________________ 4
3.0 Warranty ________________________________________________________ 5
3 Basic Safety Precautions_________________________________________ 5
1.0 Pay attention to the instructions in the Operation Manual________________ 5
4 Transportation & Storage_________________________________________ 5
1.0 Testing upon acceptance __________________________________________ 5
2.0 Packaging _______________________________________________________ 5
5 Unpacking, Setup and Commissioning _____________________________ 5
Body fat balance
1.0 Installation Site, Location of Use ____________________________________ 5
2.0 Unpacking _______________________________________________________ 6
3.0 Battery operation (insertion and removal)_____________________________ 6
6 Operation______________________________________________________ 7
1.0 Controls_________________________________________________________ 7
1.0.0 Display ______________________________________________________________ 7
2.0.0 Keys and display overview _______________________________________________ 7
7 Using the balance_______________________________________________ 8
1.0 Entering person-related data________________________________________ 8
2.0 Usage as body fat balance__________________________________________ 9
8 Error message_________________________________________________ 12 9 Service, maintenance, disposal___________________________________ 12
1.0 Cleaning _______________________________________________________ 12
2.0 Service, maintenance_____________________________________________ 12
3.0 Disposal________________________________________________________ 12
10 Instant help _________________________________________________ 13
2
MFB -BA-e-0810

1 Technical Data

KERN MFB 150K100
Readability (d) 100 g Weighing range (max) 150 kg Weighing Units kg, lb Reproducibility +- (100 g +1%) Linearity +- (100 g +1%)
Stabilization time (typical) 2 – 3 sec.
Electric Supply
Auto Off after 5 seconds Operating temperature + 5°C … + 35°C Storage temperature - 20°C … + 60°C Humidity of air max. 80 % (not condensing) Housing (B x D x H) mm Weight kg (net) 1.4
Battery operated 4 x 1.5V, size AAA
Battery life for three times daily use: 1 year
300 x 320 x 55
MFB -BA-e-0810
3

2 Basic Information (General)

These body fat balance are designed for the determination of body fat, water content, muscle ratio and bone weight according to the so-called impedance method. This method is applied to determine the resistance value of the human body with the help of electrical impulses. A high fat ratio in the body will for instance increase the resistance value. For individual calculations, it is possible to store basic data (such as body height, age and gender) for up to 10 persons.
These balance are only designed to deliver reliable values for persons aged 10 – 80 and a body height of 100 - 220 cm. In order to obtain exact results it is recommended to step on the weighing plate lightly clad, whilst for the analysis of body components it is essential to be barefoot.
These balance should not be used by persons requiring a cardiac pacemaker, a respirator or other devices.

2.1 Proper use

These balance are designed for the determination of weight (in kg/lb), body fat ratio ( in % ), body water ratio ( in % ), muscle ratio ( in % ) and bone weight ( in kg ) of persons in a private domain. Utilisation of this balance in the medical field is not permissible. The weighing process requires that the person steps on the weighing plate barefoot, with one foot at a time on the 6 metal platelets. Once a stable weighing value has been reached the weighing value can be read, followed by the other measured values. .

2.2 Improper Use

Do not use balance for dynamic weighings. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance. (Example: Slowly draining fluids from a container on the balance. ) Do not leave permanent load on the weighing plate. This may damage the measuring system. Take care to avoid impacts and overloading of balance above the specified maximum load (max) under all circumstances. This could cause damage to the balance. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.