KERN & SOHN EOB F User Manual

KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com
Instruction Manual Platform/floor scales
KERN EOB_F
Version 1.0
07/2013 GB
EOB_F-BA-e-1310
2
GB
KERN EOB_F
Version 1.0 07/2013
Operating instructions Platform/floor scales
Contents
1 Technical Data ............................................................................................... 3
2 Appliance overview ....................................................................................... 5
3 Overview of display ....................................................................................... 6
3.1 Keyboard overview .................................................................................................... 7
4 Basic Information (General) .......................................................................... 8
4.1 Proper use ................................................................................................................. 8
4.2 Improper Use ............................................................................................................. 8
4.3 Warranty .................................................................................................................... 8
4.4 Monitoring of Test Resources .................................................................................... 9
5 Basic Safety Precautions .............................................................................. 9
5.1 Pay attention to the instructions in the Operation Manual .......................................... 9
5.2 Personnel training ...................................................................................................... 9
6 Transportation & Storage .............................................................................. 9
6.1 Testing upon acceptance ........................................................................................... 9
6.2 Packaging / return transport ...................................................................................... 9
7 Unpacking, Setup and Commissioning ..................................................... 10
7.1 Installation Site, Location of Use ...............................................................................10
7.2 Unpacking and erection ............................................................................................10
7.2.1 Scope of delivery / serial accessories....................................................................................... 11
7.2.2 Assembly instructions for the use of the wall fixture ................................................................. 11
7.3 Mains connection ......................................................................................................12
7.4 Battery operation ......................................................................................................12
7.5 Initial Commissioning ................................................................................................14
8 Adjustment ................................................................ ................................ ... 14
9 Operation Mode ........................................................................................... 16
Start-up ................................................................................................................................16
Switching Off ........................................................................................................................16
Weighing ..............................................................................................................................17
Switch over weighing unit ....................................................................................................17
Taring ...................................................................................................................................18
Hold function (animal weighing function) ..............................................................................20
Plus/minus weighings ...........................................................................................................21
Setting channels ...................................................................................................................22
10 Menu ............................................................................................................. 24
11 Service, maintenance, disposal .................................................................. 25
11.1 Cleaning ...................................................................................................................25
11.2 Service, maintenance ...............................................................................................25
11.3 Disposal ....................................................................................................................25
12 Error messages, troubleshooting guide .................................................... 25
13 Declaration of Conformity ........................................................................... 27
EOB_F-BA-e-1310
3
KERN
EOB
35K2F
EOB
60K2F
EOB
60K2LF
Readability (d)
10 g
20 g
20 g
Weighing range (max)
35 kg
60 kg
60 kg
Reproducibility
10 g
20 g
20 g
Linearity
± 20 g
± 40 g
± 40 g
Recommended adjustment weight, not added (class)
20 kg
(M2)
40 kg
(M2)
40 kg
(M2)
Stabilization time (typical)
3 sec.
Warm-up time
10 min.
Input Voltage
220 V- 240 V, AC 50 Hz
Power pack secondary voltage
9 V, 100 mA
Battery (optional)
6 x 1.5 V AA (= 9 V)
Battery operation period
Display unit: 70 h
Platform: 110 h
Auto Off
3 min.
Weighing Units
kg, lb
Ambient temperature
+ 10°C …+ 35°C
Humidity of air
max. 80 % (not condensing)
Display unit (B x D x H) mm
210 x 110 x 45
Radio transmission to weighing platform
Range: max. 10 m on free surface, free of buildings
Weighing surface mm
314,5 x 304,5
314,5 x 304,5
550 x 550
Weight kg (net)
4
4
1 Technical Data
EOS_F-BA-e-1310
13,5
4
KERN
EOB
150K2F
EOB
150K2LF
EOB
300K1LF
Readability (d)
50 g
50 g
100 g
Weighing range (max)
150 kg
150 kg
300 kg
Reproducibility
50 g
50 g
100 g
Linearity
± 100 g
± 100 g
± 200 g
Recommended adjustment weight, not added (class)
100 kg
(M2)
100 kg
(M2)
200 kg
(M2)
Stabilization time (typical)
3 sec.
Warm-up time
10 min.
Input Voltage
220 V- 240 V, AC 50 Hz
Power pack secondary voltage
9 V, 100 mA
Battery (optional)
6 x 1.5 V AA (= 9 V)
Battery operation period
Display unit: 70 h
Platform: 110 h
Auto Off
3 min.
Weighing Units
kg, lb
Ambient temperature
+ 10°C …+ 35°C
Humidity of air
max. 80 % (not condensing)
Display unit (B x D x H) mm
210 x 110 x 45
Radio transmission to weighing platform
Range: max. 10 m on free surface, free of buildings
Weighing surface mm
314,5 x 304,5
550 x 550
550 x 550
Weight kg (net)
4
13,5 13,5
EOB_F-BA-e-1310
5
Weighing platform 314,5 x 304,5 mm
Weighing platform 550 x 550 mm
1. Power On-Off
2. Mains connection
2 Appliance overview
Weighing plate, stainless steel Display unit
Display unit with wall fixing device:
EOS_F-BA-e-1310
6
No.
Description
1
Is displayed, when the battery capacity is exhausted.
2
Balance zero display: Should the balance not exactly display zero despite of unloaded weighing plate, use taring function (see chap. 7).
The balance will be set to zero after a short standby time.
3
Display of the three possible channels
4
Display of receiving mode
5
Stability display: If the display shows the stability display [ο] the balance is in a stable
status. The [ο] indication disappears if the condition is unstable.
6
Hold/animal weighing function active, see chap. 7
7
Weighing unit [kg lb], (see chap. 7) „Switch-over weighing unit“
8
Stored tare value, (see chap. 7) „Taring“
9
Contact-free taring field
3 Overview of display
EOB_F-BA-e-1310
7
Key
Function
Turn on/off balance
Hold/ animal weighing function
+
Tare balance by
The TARE button or The contact-free taring field
Switch-over weighing unit
Select channel
3.1 Keyboard overview
EOS_F-BA-e-1310
8
4 Basic Information (General)
4.1 Proper use
The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read.
4.2 Improper Use
Do not use balance for dynamic add-on weighing procedures, if small amounts of goods to be weighed are removed or added. The “stability compensation“ installed in the balance may result in displaying an incorrect measuring value! (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.
4.3 Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
Mechanical damage or damage by media, liquids, natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
EOB_F-BA-e-1310
9
Keep all parts of the original packaging for a possibly
required return.
Only use original packaging for returning.
Prior to dispatch disconnect all cables and remove
loose/mobile parts.
Reattach possibly supplied transport securing devices.
Secure all parts such as the glass wind screen, the
weighing platform, power unit etc. against shifting and damage.
4.4 Monitoring of Test Resources
In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost.
5 Basic Safety Precautions
5.1 Pay attention to the instructions in the Operation Manual
Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.
5.2 Personnel training
The appliance may only be operated and maintained by trained personnel.
6 Transportation & Storage
6.1 Testing upon acceptance
When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.
6.2 Packaging / return transport
EOS_F-BA-e-1310