KERN & SOHN DS User Manual

KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Internet: www.kern-sohn.com
Operating instructions
platform scales
KERN 572/573/KB/DS/FKB/KBJ
Version 7.2
10/2014
Fax: +49-[0]7433-9933-149
Precision/ compact balances and
GB
572/573/KB/DS/FKB/KBJ-BA-e-1472
KERN 572/573/KB/DS/FKB/KBJ
Precision/compact balances and platform scales
GB
Version 7.2 10/2014
Operating instruction
Table of contents:
1 MODE - MENUE ....................................................................................................... 4
2 Technical data ......................................................................................................... 6
2.1 KERN 572 ..............................................................................................................................................6
2.2 KERN 573 ..............................................................................................................................................9
2.3 KERN KB/KBJ ....................................................................................................................................10
2.4 KERN DS .............................................................................................................................................14
2.5 KERN FKB ..........................................................................................................................................19
3 Fundamental information (general) ..................................................................... 22
3.1 Intended use .......................................................................................................................................22
3.2 Inappropriate use ...............................................................................................................................22
3.3 Guarantee ...........................................................................................................................................22
3.4 Monitoring the test substances .......................................................................................................22
4 Fundamental safety information .......................................................................... 23
4.1 Observe the information in the operating instructions .................................................................23
4.2 Staff training .......................................................................................................................................23
5 Transport and storage .......................................................................................... 23
5.1 Acceptance check ..............................................................................................................................23
5.2 Packaging ...........................................................................................................................................23
6 Unpacking, installation and commissioning ...................................................... 24
6.1 Place of installation, place of use ....................................................................................................24
6.2 Unpacking ..........................................................................................................................................24
6.2.1 Installation ............................................................................................................................................24
6.3 Mains supply ......................................................................................................................................24
6.4 Battery operation FKB .......................................................................................................................25
6.5 Connecting peripheral equipment ...................................................................................................25
6.6 Initial start-up .....................................................................................................................................25
6.7 Adjustment .........................................................................................................................................25
6.8 Adjusting (go to 7.2.6) .......................................................................................................................26
6.8.1 Adjusting for verification (KERN 573; FKB-M; KB-NM; DS-M) ............................................................26
6.9 Verification .........................................................................................................................................27
572/573/KB/DS/FKB/KBJ-BA-e-1472 2
7 Operation ............................................................................................................... 28
7.1 Display control panel ........................................................................................................................28
7.2 Operation ............................................................................................................................................29
7.2.1 Weighing with Tare ..............................................................................................................................29
7.2.2 Count – Selection reference piece .......................................................................................................29
7.2.3 Percent % ............................................................................................................................................29
7.2.4 Formula Weighing ...............................................................................................................................29
7.2.5 Tolerance Weighing .............................................................................................................................29
7.2.6 Adjust ...................................................................................................................................................31
7.2.7 Preselect Tare .....................................................................................................................................31
7.2.8 Auto Tare active ...................................................................................................................................31
7.2.9 Filter / Speed........................................................................................................................................31
7.2.10 Auto Off active .................................................................................................................................31
7.2.11 Variable Factor ................................................................................................................................31
7.2.12 Preselect Unit ..................................................................................................................................31
7.2.13 Animal weighing: .............................................................................................................................33
7.2.14 Swap: ...............................................................................................................................................33
7.3 Display background illumination .....................................................................................................35
7.4 Interface RS 232 C .............................................................................................................................35
7.5 RS 232 C Data output via interface RS 232 C .................................................................................36
7.5.1 Description of the data transfer............................................................................................................37
7.5.2 Numerator ............................................................................................................................................37
7.6 Printer .................................................................................................................................................37
7.7 Underfloor weighing ..........................................................................................................................38
8 Maintenance, upkeep, disposal ........................................................................... 39
8.1 Cleaning ..............................................................................................................................................39
8.2 Maintenance, upkeep ........................................................................................................................39
8.3 Disposal ..............................................................................................................................................39
9 Troubleshooting .................................................................................................... 40
10 Declaration of c onform ity ..................................................................................... 41
572/573/KB/DS/FKB/KBJ-BA-e-1472 3

1 MODE - MENUE

Models 572 / KB / DS / FKB / n on -verifiable:
Important!
The modified settings - as well as the adjustment - must be stored when switching-off, via the ON/OFF button.
572/573/KB/DS/FKB/KBJ-BA-e-1472 4
Models 573-NM; KB-NM; DS-M; FKB-M; KBJ-NM:
Important!
The modified settings - as well as the adjustment - must be stored when switching-off, via the ON/OFF button.
572/573/KB/DS/FKB/KBJ-BA-e-1472 5
KERN
572-30
572-31
572-32
572-33
Readability (d)
0.001 g
0.001 g
0.001 g
0.01 g
Weighing range (max)
240 g
300 g
420 g
1600 g
Taring range (subtractive)
240 g
300 g
420 g
1600 g
Reproducibility
0.001 g
0.002 g
0.002 g
0.01g
Linearity
± 0.003 g
± 0.005 g
± 0.005 g
± 0.03 g
Smallest piece weight
0.001 g
0.001 g
0.001 g
0.01 g
200/240 g
200/300 g
300/400 g
1.5/1.6 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
4 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
steel mm
Units
see menu
Weight kg (net)
2.3
2.3
2.3
2.3
Data interface
yes (RS232)

2 Technical data

2.1 KERN 572

Adjustment points 50/100/
Recommended adjusting
Permitted environmental
Weighing plate stainless
Ø 106 Ø 106 Ø 106 Ø 150
50/100/
200 g 200 g +100 g 200 g + 200 g 1 kg + 500 g
+10 °C ... + 40 °C
100/200/
0.5/1.0/
572/573/KB/DS/FKB/KBJ-BA-e-1472 6
KERN
572-35
572-37
572-39
572-43
Readability (d)
0.01 g
0.01 g
0.01 g
0.1 g
Weighing range (max)
2400 g
3000 g
4200 g
10000 g
Taring range (subtractive)
2400 g
3000 g
4200 g
10000 g
Reproducibility
0.01 g
0.02 g
0.02 g
0.1g
Linearity
± 0.03 g
± 0.05 g
± 0.05 g
± 0.3 g
Smallest piece weight
0.01 g
0.01 g
0.01 g
0.1 g
2.0/2.4 kg
2.0/3.0 kg
3.0/4.0 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
4 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
steel mm
Units
see menu
Weight kg (net)
2.3
2.3
2.3
2.7
Data interface
yes (RS232)
Adjustment points 0.5/1.0/
Recommended adjusting
Permitted environmental
Weighing plate stainless
Ø 150 Ø 150 Ø 150 160 x 200
1.0/1.5/
2 kg 2 kg + 1 kg 2 kg + 2 kg 10 kg
+10 °C ... + 40 °C
1.0/2.0/
2/5/10 kg
572/573/KB/DS/FKB/KBJ-BA-e-1472 7
KERN
572-45
572-49
572-55
572-57
Readability (d)
0.05 g
0.1 g
0.05 g
0.1 g
Weighing range (max)
12000 g
16000 g
20000 g
24000 g
Taring range (subtractive)
12000 g
16000 g
20000 g
24000 g
Reproducibility
0.05 g
0.1 g
0.1 g
0.1g
Linearity
± 0.15 g
± 0.3 g
± 0.25 g
± 0.3 g
Smallest piece weight
0.05 g
0.1 g
0.05 g
0.1 g
Adjustment points
2/5/10/12 kg
5/10/15/16 kg
5/10/15/20 kg
5/10/15/20/24 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
steel mm
Units
see menu
Weight kg (net)
2.7
2.7
2.7
2.7
Data interface
yes (RS232)
Recommended adjusting
Permitted environmental
Weighing plate stainless
10 kg 10 kg + 5 kg 20 kg 20 kg
+10 °C ... + 40 °C
160 x 200 160 x 200 160 x 200 160 x 200
572/573/KB/DS/FKB/KBJ-BA-e-1472 8
KERN
573-34NM
573-46NM
Accuracy class
II
II
Readability (d)
0.01 g
0.1 g
Verification value (e)
0.1 g
1 g
Weighing range (max)
650 g
6500 g
Minimum load (Min)
0.5 g
5 g
Taring range (subtractive)
650 g
6500 g
Reproducibility
0.01 g
0.1 g
Linearity
± 0.03 g
± 0.3 g
Smallest piece weight
0.01 g
0.1 g
Adjustment points
200g/500g/600g
2/5/6 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
Housing (B x D x H) mm
180 x 310 x 90
Vibration filter
yes
steel mm
Units
g, kg
g, kg
Weight kg (net)
2.3
2.7
Data interface
yes (RS232)

2.2 KERN 573

Recommended adjusting
Permitted environmental
Weighing plate stainless
500 g + 100 g 5 kg + 1 kg
+10 °C ... + 30 °C
Ø 150 160 x 200
572/573/KB/DS/FKB/KBJ-BA-e-1472 9
KERN
KB 120-3N
KB 240-3N
KB 360-3N
Readability (d)
0.001 g
0.001 g
0.001 g
Weighing range (max)
120 g
240 g
360 g
Taring range (subtractive)
120 g
240 g
360 g
Reproducibility
0.001 g
0.001 g
0.002 g
Linearity
± 0.003 g
± 0.003 g
± 0.005 g
Smallest piece weight
0.001 g
0.001 g
0.001 g
200/240 g
300/360 g
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
4 hours
Housing (B x D x H) mm
167 x 250 x 85
Vibration filter
yes
steel mm
Units
see menu
Weight kg (net)
1 1 1
Data interface
yes (RS232)
pack KB-A01N

2.3 KERN KB/KBJ

Adjustment points 20/50/100/120 g 100/150/
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
100 g 200 g 200 g + 100 g
+10 °C ... + 40 °C
Ø 81 Ø 81 Ø 81
7,2 V / 2000mAh
100/200/
572/573/KB/DS/FKB/KBJ-BA-e-1472 10
KERN
KB 1200-2N
KB 2000-2N
KB 2400-2N
KB 3600-2N
Readability (d)
0.01 g
0.01 g
0.01 g
0.01 g
Weighing range (max)
1 200 g
2 000 g
2 400 g
3 600 g
Taring range (subtractive)
1 200 g
2 000 g
2 400 g
3 600 g
Reproducibility
0.01 g
0.01 g
0.01 g
0.02 g
Linearity
± 0.03 g
± 0.03 g
± 0.03 g
± 0.05 g
Smallest piece weight
0.01 g
0.01 g
0.01 g
0.01 g
Adjustment points
0.2/0.5/1.0/1.2 kg
0.5/1.0/1.5/2.0 kg
1.0/1.5/2.0/2.4 kg
1.0/2.0/3.0/3.6 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
4 hours
Housing (B x D x H) mm
167 x 250 x 85
Vibration filter
yes
steel mm
Units
see menu
Weight kg (net)
1.5
1.5
1.5
1.5
Data interface
yes (RS232)
pack KB-A01N
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
1 000 g 2 000 g 2 000 g 2 kg + 1 kg
+10 °C ... + 40 °C
130 x 130 130 x 130 130 x 130 130 x 130
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 11
KB
10000-1N
KB
10k0.05N
Taring range (subtractive)
Reproducibility
Linearity
Smallest piece weight
Adjustment points
weight F1 (not supplied)
Stabilization time (typical)
perature
Warm-up time
Housing (B x D x H) mm
mm
Units
Vibration filter
Weight kg (net)
Data interface
KB-A01N
KERN
Readability (d) 0.1 g 0.05 g Weighing range (max) 10 000 g 10 000 g
10 000 g 10 000 g
0.1 g 0.05 g
0.3 g 0.15 g
0.1 g 0.05 g
2/5/10 kg 2/5/10 kg
Recommended adjusting
Permitted environmental tem-
Weighing plate stainless steel
Rechargeable battery pack
10 kg 10 kg
3 sec. 3 sec.
+10 °C ... + 40 °C +10 °C ... + 40 °C
2 hours 2 hours
167 x 250 x 85 167 x 250 x 85
150 x 170 150 x 170 see menu see menu
yes yes
1.7 1.7
yes (RS232) yes (RS232)
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 12
KB
650-2NM
KB
6500-1NM
KBJ
650-2NM
Accuracy class
II
II
II
Readability (d)
0.01 g
0.1 g
0.01 g
Verification value (e)
0.1 g
1 g
0.1 g
Weighing range (max)
650 g
6 500 g
650 g
Minimum load (Min)
0.5 g
5 g
0.5 g
Taring range (subtractive)
650 g
6 500 g
650 g
Reproducibility
0.01 g
0.1 g
0.01 g
Linearity
± 0.03 g
± 0.3 g
±0.03 g
Smallest piece weight
0.01 g
0.1 g
0.01 g
Adjustment points
200/500/600 g
2/5/6 kg
-
weight F1 (not supplied)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
Housing (B x D x H) mm
167 x 250 x 85
Vibration filter
yes
steel mm
Units
g, kg, ct
Weight kg (net)
1.5
1.7
2.1
Data interface
yes (RS232)
pack KB-A01N
KERN
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
600 g 6.0 kg Int. adjustment
+10 °C ... + 30 °C
130 x 130 150 x 170 130 x 130
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 13
DS
3K0.01S
DS
5K0.05S
DS
8K0.05
DS
10K0.1S
Readability (d)
0.01 g
0.05 g
0.05 g
0,1 g
Weighing range (max)
3 000 g
5 000 g
8 000 g
10.000 g
Taring range (subtractive)
3 000 g
5 000 g
8 000 g
10.000 g
Reproducibility
0.02 g
0.05 g
0.05 g
0.1 g
Linearity
± 0.05 g
± 0.15 g
± 0.15 g
±0.3 g
Smallest piece weight
0.01 g
0.05 g
0.05 g
0.1 g
Adjustment points
1/2/3 kg
2/5/10 kg
2/4/5/7/8 kg
2/5/10 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
228 x 228 x 70
228 x 228 x 70
315 x 305 x 70
228 x 228 x 70
Vibration filter
steel mm
Units
see menu
see menu
see menu
see menu
Weight kg (net)
5.5
5.5
7.5
5.5
Data interface
yes (RS232)
pack KB-A01N

2.4 KERN DS

KERN
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
3 kg 10 kg 5 kg + 2 kg 10 kg
+10 °C ... + 40 °C
228 x 228 228 x 228 315 x 305 228 x 228
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 14
DS
16K0.1
DS
20K0.1
DS
30K0.1
Readability (d)
0.1 g
0.1 g
0.1 g
Weighing range (max)
16 000 g
20 000 g
30 000 g
Taring range (subtractive)
16 000 g
20 000 g
30 000 g
Reproducibility
0.1 g
0.1 g
0.2 g
Linearity
± 0.3 g
± 0.3 g
± 0.5 g
Smallest piece weight
0.1 g
0.1 g
0.1 g
Adjustment points
5/10/15/16 kg
5/10/15/20 kg
10/15/20/30 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
Housing (B x D x H) mm
315 x 305 x 70
Vibration filter
yes
steel mm
Units
see menu
see menu
see menu
Weight kg (net)
7.5
7.5
7.5
Data interface
yes (RS232)
pack KB-A01N
KERN
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
10 kg + 5 kg 20kg 20 kg + 10 kg
+10 °C ... + 40 °C
315 x 305 315 x 305 315 x 305
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 15
DS
36K0.2
DS
30K0.1L
DS
36K0.2L
DS
60K0,2
Readability (d)
0.2 g
0.1 g
0.2 g
0.2 g
Weighing range (max)
36 000 g
30 000 g
36 000 g
60 000 g
Taring range (subtractive)
36 000 g
30 000 g
36 000 g
60 000 g
Reproducibility
0.2 g
0.2 g
0.2 g
0.4 g
Linearity
± 0.6 g
± 0.5 g
± 0.6 g
± 1.0 g
Smallest piece weight
0.2 g
0.1 g
0.2 g
0.2 g
30/36 kg
30 kg
30/36 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
315 x 305 x 70
450 x 350 x 115
Vibration filter
yes
steel mm
Units
see menu
see menu
see menu
see menu
Weight kg (net)
7.5
9.5
9.5
9.5
Data interface
yes (RS232)
pack KB-A01N
KERN
Adjustment points 10/15/20/
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
20 kg + 10 kg 20 kg + 10 kg 20 kg + 10 kg 50 kg
315 x 305 450 x 350
10/15/20/
+10 °C ... + 40 °C
7,2 V / 2000 mAh
10/15/20/
20/30/50/60 kg
572/573/KB/DS/FKB/KBJ-BA-e-1472 16
DS
65K0.5
DS
100K0.5
DS
150K1
Readability (d)
0.5 g
0.5 g
1 g
Weighing range (max)
65 000 g
100 000 g
150 000 g
Taring range (subtractive)
65 000 g
100 000 g
150 000 g
Reproducibility
0.0 g
0.5 g
1 g
Linearity
± 1.5 g
± 1.5 g
± 3 g
Smallest piece weight
0.5 g
0.5 g
1 g
Adjustment points
20/30/50/60 kg
20/50/100 kg
50/100/150 kg
3 x 50 kg
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
2 hours
Housing (B x D x H) mm
450 x 350 x 115
Vibration filter
yes
steel mm
Units
see menu
see menu
see menu
Weight kg (net)
9.5
Data interface
yes (RS232)
pack KB-A01N
KERN
Recommended adjusting weight F1 (not supplied)
Permitted environmental
Weighing plate stainless
Rechargeable battery
50 kg 50 kg + 50 kg
3 x 50 kg
+10 °C ... + 40 °C
450 x 350
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 17
DS
65K1M
Accuracy class
II
Readability (d)
1 g
Verification value (e)
10 g
Weighing range (max)
65 000 g
Minimum load (Min)
50 g
Taring range (subtractive)
65 000 g
Reproducibility
1 g
Linearity
± 2 g
Smallest piece weight
1 g
Adjustment points
20/30/50/60 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
Housing (B x D x H) mm
450 x 350 x 115
Vibration filter
steel mm
Units
see menu
Weight kg (net)
9.5
Data interface
yes (RS232)
pack KB-A01N
KERN
Recommended adjusting
Permitted environmental
Weighing plate stainless
Rechargeable battery
50 kg
+10 °C ... + 30 °C
450 x 350
7,2 V / 2000 mAh
572/573/KB/DS/FKB/KBJ-BA-e-1472 18
FKB
6K0.02
FKB
8K0.05
FKB
16K0.05
FKB
16K0.1
Readability (d)
0.02 g
0.05 g
0.05 g
0.1 g
Weighing range (max)
6 000 g
8 000 g
16 000 g
16 000 g
Taring range (subtractive)
6 000 g
8 000 g
16 000 g
16 000 g
Reproducibility
0.04 g
0.05 g
0.1 g
0.1g
Linearity
± 0.1 g
± 0.15 g
± 0.25 g
± 0.3 g
Smallest piece weight
0.02 g
0.05 g
0.05 g
0.1 g
Adjustment points
2/4/5/6 kg
2/4/5/7/8 kg
5/10/15/16 kg
5/10/15/16 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
2 hours
2 hours
2 hours
2 hours
Housing (B x D x H) mm
350 x 390 x 120
Vibration filter
yes
steel mm
Units
see menu
see menu
see menu
see menu
Weight kg (net)
6.5
6.5
6.5
6.5
Data interface
yes (RS232)
Battery operation
6 x 1,5 V; Size C

2.5 KERN FKB

KERN
Recommended adjusting
Permitted environmental
Warm-up time
Weighing plate stainless
5 kg 5 kg + 2 kg 10 kg + 5 kg 10 kg + 5 kg
+10 °C ... + 40 °C
340 x 240 340 x 240 340 x 240 340 x 240
572/573/KB/DS/FKB/KBJ-BA-e-1472 19
FKB
36K0.1
FKB
36K0.2
FKB
65K0.2
FKB
65K0.5
Readability (d)
0.1 g
0.2 g
0.2 g
0.5 g
Weighing range (max)
36 000 g
36 000 g
65 000 g
65 000 g
Taring range (subtractive)
36 000 g
36 000 g
65 000 g
65 000 g
Reproducibility
0.2 g
0.2 g
0.4 g
0. g
Linearity
± 0.5 g
± 0.6 g
± 1.0 g
± 1.5 g
Smallest piece weight
0.1 g
0.2 g
0.2 g
0.5 g
Adjustment points
10/20/30/36 kg
10/20/30/36 kg
20/30/50/60 kg
20/30/50/60 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
4 hours
2 hours
4 hours
2 hours
Housing (B x D x H) mm
350 x 390 x 120
Vibration filter
yes
steel mm
Units
see menu
see menu
see menu
see menu
Weight kg (net)
6.5
6.5
6.5
6.5
Data interface
yes (RS232)
Battery operation
6 x 1,5 V; Size C
KERN
Recommended adjusting
Permitted environmental
Weighing plate stainless
20 kg + 10 kg 20 kg + 10 kg 50kg 50kg
+10 °C ... + 40 °C
340 x 240 340 x 240 340 x 240 340 x 240
572/573/KB/DS/FKB/KBJ-BA-e-1472 20
FKB
8K0.1M
FKB
65K1M
Accuracy class
II
II
Readability (d)
0.1 g
1 g
Verification value (e)
1.0 g
10 g
Weighing range (max)
8 000 g
65 000 g
Minimum load (Min)
5.0 g
50 g
Taring range (subtractive)
8 000 g
65 000 g
Reproducibility
0.1 g
1 g
Linearity
± 0.3 g
± 3 g
Smallest piece weight
0.1 g
1 g
Adjustment points
2/5/7/8 kg
20/30/50/60 kg
weight F1 (not supplied)
Humidity of air
max. 80% rel. (non-condensing)
Stabilization time (typical)
3 sec.
temperature
Warm-up time
2 hours
2 hours
Housing (B x D x H) mm
350 x 390 x 120
Vibration filter
yes
steel mm
Units
see menu
see menu
Weight kg (net)
6.5
6.5
Data interface
yes (RS232)
Battery operation
6 x 1,5 V; Size C
KERN
Recommended adjusting
Permitted environmental
Weighing plate stainless
5 kg + 2 kg 50 kg
+10 °C ... + 30 °C +10 °C ... + 30 °C
340 x 240 340 x 240
572/573/KB/DS/FKB/KBJ-BA-e-1472 21

3 Fundamental information (ge ne ral)

It is essential to read through and observe the complete operating instructions before in­stalling and commissioning.

3.1 Intended use

The balance you have acquired serves to determine the weighing value of the material to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. The weighing value can be read off after a stable weighing value has been obtained.

3.2 Inappropriate use

Do not use the balance for dynamic weighing. In the event that small quantities are re­moved or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance. (Example: Slowly draining fluids from a container on the balance.) Do not leave a permanent load on the weighing plate. This can damage the measuring equipment. Be sure to avoid impact shock and overloading the balance in excess of the prescribed maximum load rating (max.), minus any possible tare weight that is already present. This could cause damage to the balance. Never operate the balance in hazardous locations. The series design is not explosion­proof. Structural alterations may not be made to the balance. This can lead to incorrect weighing results, faults concerning safety regulations as well as to destruction of the balance. The balance may only be used in compliance with the described guidelines. Varying areas of application/planned use must be approved by KERN in writing.

3.3 Guarantee

The guarantee is not valid following
- non-observation of our guidelines in the operating instructions
- use outside the described applications
- alteration to or opening of the device
- mechanical damage and damage caused by media, liquids
- natural wear and tear
- inappropriate erection or electric installation
- overloading of the measuring equipment

3.4 Monitoring the test substances

The metrology features of the balance and any possible available adjusting weight must be checked at regular intervals within the scope of quality assurance. For this purpose, the answerable user must define a suitable interval as well as the nature and scope of this check. Information is available on KERN’s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. Test weights and balances can be adjusted quickly and at a reasonable price in KERN’s ac­credited DKD calibration laboratory (return to national normal).
572/573/KB/DS/FKB/KBJ-BA-e-1472 22

4 Fundamental safety information

4.1 Observe the information in the operating instructions

Carefully read this operation manual before setup and com­missioning, even if you are already familiar with KERN balanc­es.
Versions in other languages are non-binding translations. The only binding version is the original document in German.

4.2 Staff training

The device may only be operated and looked after by trained members of staff.

5 Transport and stor a ge

5.1 Acceptance check

Please check the packaging immediately upon delivery and the device during unpacking for any visible signs of external damage. In the case of visible damages please obtain a signature from the bearer to serve as con­firmation of damage. Do not make alterations to the goods and packaging, do not remove any consignment parts. Report the damage to the parcel service immediately in writing ( within 24 hours).

5.2 Packaging

Please retain all parts of the original packaging in case it should be necessary to return items at any time. Only the original packaging should be used for return consignments. Before despatch, disconnect all attached cables and loose/movable parts, remove weigh­ing plate. Apply any intended transport security devices. Secure all parts, e.g. glass windshield, weighing plate, power unit etc., to prevent slipping and damage.
572/573/KB/DS/FKB/KBJ-BA-e-1472 23

6 Unpacking, installation and commissioning

6.1 Place of installation, place of use

The balance is constructed in such a way that reliable weighing results can be achieved under normal application conditions. By selecting the correct location for your balance, you will be able to work quickly and pre­cisely.
Therefore please observe the following at the place of installation:
- Place the balance on a firm, level surface;
- Avoid extreme heat as well as temperature fluctuation caused by installing next to a
radiator or in the direct sunlight;
- Protect the balance against direct draughts due to open windows and doors;
- Avoid jarring during weighing;
- Protect the balance against high humidity, vapours and dust;
- Do not expose the device to extreme dampness for longer periods of time. Inad-
missible bedewing (condensation of air moisture on the device) can occur if a cold device is taken into a significantly warmer environment. In this case, please accli­matise the device for approx. 2 hours at room temperature after it has been discon­nected from the mains.
- Avoid static charging of the material to be weighed, weighing container and wind-
shield.
Major display deviations (incorrect weighing results) are possible if electromagnetic fields occur as well as due to static charging and instable power supply. It is then necessary to change the location.

6.2 Unpacking

Carefully remove the balance from its packaging, remove the plastic wrapping and posi­tion the balance in its intended working location.

6.2.1 Installation

Install the balance in such a fashion that the weighing plate is absolutely horizontally.

6.3 Mains supply

Electric power supply is by means of the external mains supply circuit. The printed voltage level must comply with the local voltage. Only use original KERN mains supply circuits. The use of other makes is subject to ap­proval by Kern.
572/573/KB/DS/FKB/KBJ-BA-e-1472 24

6.4 Battery operation FKB

To insert the batteries (6 x 1.5 V) remove the battery compartment cover. Remove it
with the help of a coin.
In the each battery tube insert three batteries in the same polarity sense. Screw down again the battery cover.
To save the battery, the background illumination can be switched off (see chap. 7.3). Moreover the AUTO-OFF function can be activated (see chap. 7.2.10). If the battery voltage drops below a critical value for operational safety, this will be indicat­ed in the display with the “BATT LOW“ information.

6.5 Connecting peripheral equipment

The balance must be disconnected from the mains before connecting or disconnecting additional equipment (printer, PC) to or from the data interface.
Only use KERN accessories and peripheral equipment with your balance. These have been ideally coordinated to your balance.

6.6 Initial start-up

A warm-up time of 2 hours stabilises the measured values after switching on. The accuracy of the balance depends on the local acceleration of the fall.
Please be sure to observe the information in the chapter on adjusting.

6.7 Adjustment

As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated – in compliance with the underlying physical weighing prin­ciple - to the existing acceleration due to gravity at its place of location ( only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out during the initial start-up, after change in location and variation of sur­rounding temperature. It is also recommendable to adjust the balance periodically during weighing operation in order to obtain exact measured values.
572/573/KB/DS/FKB/KBJ-BA-e-1472 25
Switch to the right
Adjusting function is released.
adjusting.
“Operation“. Model KBJ see 6.8.2
left for blocking.
Switch to the left
Adjusting function is blocked.
the left.
verification.
secured by a verification mark against access.

6.8 Adjusting (go to 7.2.6)

Using a precision weight, the accuracy of the balance can be checked at any time and adjusted.
Warning:
With verified balances, this precision adjustment is not possible. Exception: model KBJ with internal adjustment weight.
Adjustment procedure:
Check that the surrounding conditions are stable. A short warm-up time of about 15 minutes is recommended for stabilisation.

6.8.1 Adjusting for verification (KERN 573; FKB-M; KB-NM; DS-M) General Information:

Prior to the procedure of verification the balance has to be adjusted. Remark: The adjusting is only possible when not being blocked by the adjusting switch.
The switch for this step is located at the bottom of the housing between the two turning feet.
At the model FKB the cover plate from the housing bottom must be removed.
This setting has to be selected before starting the
Executing the adjusting according to chapter 7.2
After the adjusting has been completed successful-
ly it is necessary to turn the adjusting switch to the
After the adjusting has been completed successful­ly the adjusting has to be blocked by switching to
The balance is now prepared for the procedure of
After the verification the adjusting switch has to be
572/573/KB/DS/FKB/KBJ-BA-e-1472 26
Balances with obli gation to verify must be taken out of operation if:
6.8.2 Adjustment of the balance KBJ with internal adjustment weight
After expiring of the warm-up time (wait > 299s), the balance KBJ is automatically adjusted, whenever switched-on again. Additionally, at any time another adjustment can be released manually via the keyboard. In order to carry out an exact adjustment, the environmental influences (draught/ vibration) must be kept to an absolute minimum. The weighing pan must be placed without load. An adjustment weight is not necessary here.
Sequence of the manual adjustment:
Press the Mode key:  Display: Cal? acknowledge by Yes button  Display: int. Cal Weight / Adjustment motor starts up  Display: Auto-Calibration  Display: Calibration done  Display: 0.00 g

6.9 Verification

General introduction: According to EU directive 90/384/EEC balances must be verified if they are used as fol-
lows (legally controlled area):
a) For commercial transactions if the price of goods is determined by weighing. b) For the production of medicines in pharmacies as well as for analyses in the medi-
cal and pharmaceutical laboratory. c) For official purposes. d) For manufacturing final packages.
In cases of doubt, please contact your local trade in standard. Verification instructions
An EU type approval exists for balances described in their technical data as verifiable. If a balance is used where obligation to verify exists as described above, it must verified and re-verified in regular intervals. Re-verification of a balance is carried out according to the respective national regulations. The validity for verification of balances in Germany is e.g. 2 years. The legal regulation of the country where the balance is used must be observed!
Verification of the balance is invalid without the "seal".
The weighing result of the balance is outside the error limit. Therefore, in reg-
ular intervals load balance with known test weight (ca. 1/3 of the max. load) and compare with displayed value.
The reverification deadline has been exceeded.
572/573/KB/DS/FKB/KBJ-BA-e-1472 27

7 Operation

in MODE: Yes / asc endi ng
(see mode structure diagram page 2)
Change g-pieces
in MODE: to right
in MODE: back in weighi ng operation
Display-Symbol
Meaning
Overload: Weighing range has been exceeded
=============
Underload: Weighing range has been fallen short of
In counting and % mode: part too light
 .
Automatic tare active / In verification operation zero display
.
Preselect tare Tare pre-selection active
Difference in % during percentage weighing
Net weight of the components during formula preparation
SUM .
Gross weight of several components during formula preparation
 .
Balance is in counting mode and currently displaying the weight value of the count­ing amount
III.
For multirange balance in verification operation indication of range
Wait > 299 s
Warm-up time if verifiable (switch-on drift monitoring)

7.1 Display control panel

Keyboard
ON / OFF
Print weighing result
in MODE: No / descending
in % and counting mode:
Form reference
MODE configuration
Formula weighing
in MODE: to left
Unit changeover
==OVERLOAD==
<< .
PTA
D .
Net .
Tare
572/573/KB/DS/FKB/KBJ-BA-e-1472 28

7.2 Operation

7.2.1 Weighing with Tare

7.2.2 Count Selection reference piece

7.2.3 Percent %

7.2.4 Formula Weighing

7.2.5 Tolerance Weighing

572/573/KB/DS/FKB/KBJ-BA-e-1472 29
572/573/KB/DS/FKB/KBJ-BA-e-1472 30

7.2.6 Adjust

7.2.7 Preselect Tare

7.2.8 Auto Tare active

7.2.9 Filter / Speed

7.2.10 Auto Off active

7.2.11 Variable Factor

7.2.12 Preselect Unit

572/573/KB/DS/FKB/KBJ-BA-e-1472 31
572/573/KB/DS/FKB/KBJ-BA-e-1472 32

7.2.13 Animal weighing:

Activate via mode/animal weigh. Y/N (4xMode) Put container without measured object on the weighing surface and tare Place the measured object (animal) in the container and start with REF/YES key The value averaging in shown in the display with AVG as well as by extinguishing of
the character blocks and the subsequently fixed display value.
Printing and deleting of the average value can be triggered by the PRINT key Simple deleting is possible by pressing the TARE key.

7.2.14 Swap:

Strong filtering
572/573/KB/DS/FKB/KBJ-BA-e-1472 33
Var 1 Type xx = Gross
MODE
Var 1 Row xx XXxx
MODE
Var 1 Type 02 = Gross
Var 1 Row 02
Var 1 Col 14
Gross value active
Line 2
Column 14
REF / YES
MODE
Var 2 Type xx = Net
Var 3 Type xx = Tare
Var 4 Type xx = Pretare
Var 5 Type xx = Pcs / %
Var 6 Type xx = * / Mw
Var 7 Type xx = Numerator
Printerform
Var 1 Col xx
Printout “Gross“ line 2 / column 14
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 1. line xxxxxxxxxxxxxG 15000.0g xxxxxx 2. line
7.2.15 Contents of the form printout:
MODE / PRINTER / PRINTERFORM
572/573/KB/DS/FKB/KBJ-BA-e-1472 34
5 1
9 6

Select Baud rate

Display
1. Press MODE-key repeatedly until "PRINTER" is displayed.
grams again, or press tare key.
PRINTER?

7.3 Display background illumination

After having switched on your balance and the zero display, press the „MODE“ button to select the menu point „Backlight“. Acknowledge by pressing the „YES“ button in order to switch on the permanent background illumination. By pressing the „NO“ button, the back­ground illumination is switched off.
If the background illumination shall be switched off time-controlled (to save the battery), press the „MODE“ button to select the menu point „Backlight auto“ and confirm by press­ing the „YES“ button. The background illumination will be switched off automatically 10 sec after having reached a stable weighing value.

7.4 Interface RS 232 C

Technical Data
8-bit ASCII Code 1 start bit, 8 data bits, 1 stop bits, no parity bit Baud rate adjustable to 2400, 4800 and 9600 baud (default), 19200 baud Sup-D- 9 pol. is necessary . When working with an interface correct operation is secured only if the corresponding
KERN-interface-cable (max. 2m) is used.
Description of the jack
Sup-D- 9 pol.
Baudrate
The Baud rate for the data transfer is adjusted with the MODE-key. The following example demonstrates how to set the Baud rate 4800.
2. Press YES-key.
3. Press MODE-key repeatedly until the desired Baud rate appears (for instance 4800 Baud).
4. Press YES-key to select 4800 Baud. The tick-mark (X) con­firms the new setting.
5. Press MODE-key repeatedly until the balance displays in
572/573/KB/DS/FKB/KBJ-BA-e-1472 35
Pin 2: Transmit data Pin 3: Receive data Pin 5: Signal ground
2400 Baud
4800 Baud
4800 Baud X
0.0 g

7.5 RS 232 C Data output via interface RS 232 C RS 232 C Data output via interface RS 232 C

General information
As a condition for the data transfer between the balance and a peripheral device (for in­stance printer, PC ...) both devise have to be set on the same interface parameter (for in­stance baud rate, parity ...). There are 5 methods for the data output via RS 232 C
Data output via PRINT-Key
The printing process can be released by the PRINT-key. In this case the settings AUTO­PRINT and AUTPRINT PC should be deselected.
AUTOPRINT (Data output, after having loaded the balance)
The setting AUT OPRINT is in the PRINT ER-routine, and there it can be selected or dese­lected. When AUTOPRINT is active the actual weighing value will be sent via the RS 232 interface when the balance has been unloaded and then loaded after having achieved the stability.
AUTOPRINT PC (Continuous data output)
The setting AUT PRINT PC is in th e PRINTER-routine, and there it can be selected or de­selected. When AUTOPRINT PC is active the actual weighing values will be sent continu­ously via the RS 232 interface.
Data output by transfer of remote controls
The following functions can be released by the remote controls that will be transferred as ASCII signs to the balance.
t Tare. w a weighing value (or unstable) is sent via RS 232 interface. s a stable weighing value is sent via RS 232 interface. If the balance receives the command w or s, it acts without printing delay.
Output on bar code printer The data transfer mode has to be set on „Barcode“. As bar code printer a Zebra printer model LP2824 is provided. Take into account that the output format of the balance is fixedly defined and cannot be changed. The printer format is stored in the printer, i.e. in case of a failure the printer cannot be changed with a new one from factory, previously it is necessary that KERN installs the re­spective software.
The Zebra printer and the balance must be connected to the delivered interface cable when they are switched off.
After switching-on both appliances, and after reaching the status ready-for-operation, a label will be printed out when pressing the key.
572/573/KB/DS/FKB/KBJ-BA-e-1472 36
Bit-Nr.
1 2 3 4 5 6 7 8 9
10
11
12
13
14
15
16
17
18 B* N N N B B B B B
0 . 0 0 E E E
CR
LF

7.5.1 Description of the data transfer

Structure of each data transfer:
N = Numerator B*: = Blank or in the range of zero point.
.
, g: = Blank or weighing value with unit, depending on the load on the weighing plate.
B, 0, E = Unit CR: = Carriage Return LF: = Line Feed

7.5.2 Numerator

The Numerator is found under the menu point “Printer” and can be activated and deac­tivated. When editing data with the use of the print option, the range of the numerator will increase by one place.

7.6 Printer

With the serial data output RS 232 a printer can be connected. The printout shows the weight in grams. When the counting mode is selected the number of pieces or the weight is printed. When the percent mode is selected, the percentage or the weight will be printed. Press The PRINT-key to print weighing results. Select the enu­merator to number the weighing continuously. Turn off the balance or use the CLEAR function to Reset the enumerator to (000).
572/573/KB/DS/FKB/KBJ-BA-e-1472 37

7.7 Underfloor weighing

Objects which, because of their size or shape, cannot be put on the scale, can be weighed by means of underfloor weighing.
Proceed as follows:
Switch off the balance.
Turn the balance over, without loading the balance plate.
Open the cover plate on the base of the balance.
Hang on the hook for underfloor weighing .
Place the balance over an opening.
Hang the item to be weighed on the hook and carry out weighing.
! CAUTION !
Take care that the hooks use d for the underfloor weighing are stable enough to hold the goods which you wish to weigh (risk of breakage). Always make sure that there are no living beings or materials below the load that could be injured or damaged.
! NOTE !
After completing the underfloor weighing, the opening in the fl oor of the balance must be closed again (dust protection).
572/573/KB/DS/FKB/KBJ-BA-e-1472 38

8 Maintenance, upkeep, disposal

8.1 Cleaning

Please disconnect the device from the operating voltage before cleaning. Only use a cloth dampened with mild suds and not aggressive cleaning agents (solvents
or similar). Please ensure that fluids are not able to get into the device and rub off using a clean, soft cloth. Loose sample residue/powder can be removed carefully using a brush or hand vacuum cleaner.
Remove any spilt material to be weighed immediately.

8.2 Maintenance, upkeep

The device may only be opened by trained service engineers authorised by KERN. Disconnect from the mains supply before opening.

8.3 Disposal

The operating company shall dispose of the packaging and the device in compliance with the valid national or regional law of the operating location.
572/573/KB/DS/FKB/KBJ-BA-e-1472 39
Interruption
Possible cause
Weight display is not illuminated.
The balance is not switched on.
rupted (mains cable not plugged in/faulty).
Power supply interrupted. .
ally
Table/floor vibrations
device if possible)
correct
Adjustment is no longer correct.
device if possible)

9 Troubleshooting

The balance should be switched off for a short time following an interruption in the pro­gramme sequence and disconnected from the mains supply. It is then necessary to repeat the weighing process from the beginning.
Help:
The weight display changes continu-
The weighing result is obviously in-
The mains supply connection has been inter-
Draught/air movement
The weighing plate is in contact with foreign
matter.
Electromagnetic fields / static charging (choose different location/switch off interfering
The balance display is not set to zero
Great fluctuations in temperature.
Electromagnetic fields / static charging
(choose different location/switch off interfering
Switch the balance off if other error messages should appear and then switch on again. Contact the manufacturer if the error message does not disappear.
572/573/KB/DS/FKB/KBJ-BA-e-1472 40

10 Declaration of c onf ormity

KERN & Sohn GmbH
D-72322 Balingen-Frommern
E-Mail: info@kern-sohn.de
Tel: 0049-[0]7433- 9933-0
Internet: www.kern-sohn.de
D
Konformitäts­erklärung
Wir er klären hiermit, dass das Produk t, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt.
GB
Declaration of conformity
We hereby declare that the product to which this declaration refers conf orms with the following standards.
CZ
Prohlášení o shode
Tímto prohlašujem e, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami.
E
Declaración de conformidad
Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes
F
Déclaration de conformité
Nous déclarons avec cela respons abilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après.
I
Dichiarazione di conformitá
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferi­sce è conforme alle norme di seguito citate.
NL
Conformiteit­verklaring
Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt.
P
Declaração de conformidade
Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes.
PL
Deklaracja
zgodności
Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy,
jest zgodny z poniższymi normami.
RUS
Заявление о
соответствии
Мы заявляем, что продукт, к которому относится данная декларация,
соответствует перечисленным ниже нормам.
EU Directive
Standards
2004/108/EC
EN 55011:2009+A1:2010
EN 45501: 1992-10+AC: 1993-08
2006/95/EC
EN 60950
2011/65/EU
EN 50581:2012
Signature
Datum
17.07.2014
Ort der Ausstellung
Place of issue
72336 Balingen
Albert Sauter KERN & Sohn GmbH
Geschäftsführer
Managing director
KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: info@kern-sohn.com, Internet: www.kern-sohn.com
Postfach 4052
Fax: 0049-[0]7433-9933-149
Declaration of conformity
EC-Konformitätserklärung EC-Declaration of -Conformity
Déclaration de conformité EC-Declar aci ón de Conformidad
EC­EC-Dichiarazione di conformità EC-Conformiteitverklaring EC- Declaração de conformidade EC- Prohlášení o shode EC-Deklaracja zgodności EC-Заявление о соответствии
Electronic Balance: KERN 572 / 573 / FKB / KB..N / DS
EN55022:2010/AC:2011 EN 55024: 2010 EN 61000-3-3:2008 EN 61000-3-2:2006-04+A1:2009+A2:2009 OIML R 76-1:2006
Date
Signatur
572/573/KB/DS/FKB/KBJ-BA-e-1472 41
KERN & Sohn GmbH
D-72322 Balingen-Frommern
E-Mail: info@kern-sohn.de
Tel: 0049-[0]7433- 9933-0
Internet: www.kern-sohn.de
D
Konformitäts­erklärung
Wir er klären hiermit, dass das Produk t, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt.
GB
Declaration of conformity
We hereby declare that the product to which this declaration refers conform s with the following standards.
CZ
Prohlášení o shode
Tímto prohlašujem e, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami.
E
Declaración de conformidad
Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes
F
Déclaration de conformité
Nous déclarons avec cela respons abilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après.
I
Dichiarazione di conformitá
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferi­sce è conforme alle norme di seguito citate.
NL
Conformiteit­verklaring
Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt.
P
Declaração de conformidade
Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes.
PL
Deklaracja zgodności
Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy,
jest zgodny z poniższymi normami.
RUS
Заявление о
соответствии
Мы заявляем, что продукт, к которому относится данная декларация,
соответствует перечисленным ниже нормам.
EU Directive
Standards
2004/108/EC
EN 55011:2009+A1:2010
EN 45501: 1992-10+AC: 1993-08
2006/95/EC
EN 60950
2011/65/EU
EN 50581:2012
Signature
Datum
17.07.2014
Ort der Ausstellung
Place of issue
72336 Balingen
Albert Sauter KERN & Sohn GmbH
Geschäftsführer
Managing director
KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: info@kern-sohn.com, Internet: www.kern-sohn.com
Postfach 4052
Fax: 0049-[0]7433-9933-149
Declaration of conformity
EC-Konformitätserklärung EC-Declaration of Conformity
Déclaration de conformité EC-Declar aci ón de Conf or m i dad
EC­EC-Dichiarazione di conformità EC-Conformiteitverklaring EC- Declaração de conformidade EC- Prohlášení o shode EC-Deklaracja zgodności EC-Заявление о соответствии

Electronic Balance: KERN KBJ_NM

EN55022:2010/AC:2011 EN 55024: 2010 EN 61000-3-3:2008 EN 61000-3-2:2006-04+A1:2009+A2:2009 OIML R 76-1:2006
Date
Signatur
572/573/KB/DS/FKB/KBJ-BA-e-1472 42