KERN CPB 3K0.1, CPB 6K0.2, CPB 15K0.5, CPB 30 K1 Operating Manual

GB
KERN CPB
Version 1.2 2/2007
Operating Manual Counting balance
CPB-BA-defsi-0712
3
7
Contents
1 Technical data _________________________________________________ 39
2 Declaration of conformity _______________________________________ 41
3 Device overview _______________________________________________ 43
3.1 Overview of display ______________________________________________ 44
3.1.1 Display weight _______________________________________________________ 44
3.1.2 Display reference weight _______________________________________________ 44
3.1.3 Display quantity ______________________________________________________ 44
3.2 Keyboard overview_______________________________________________ 45
4 Basic Information (General)______________________________________ 46
4.1 Proper use______________________________________________________ 46
4.2 Improper Use ___________________________________________________ 46
4.3 Warranty _______________________________________________________ 46
4.4 Monitoring of Test Resources ______________________________________ 47
5 Basic Safety Precautions ________________________________________ 47
5.1 Pay attention to the instructions in the Operation Manual_______________ 47
5.2 Personnel training _______________________________________________ 47
6 Transport and storage __________________________________________ 47
6.1 Testing upon acceptance _________________________________________ 47
6.2 Packaging ______________________________________________________ 47
7 Unpacking, Setup and Commissioning ____________________________ 48
7.1 Installation Site, Location of Use ___________________________________ 48
7.2 Unpacking ______________________________________________________ 48
7.2.1 Setup ______________________________________________________________ 48
7.2.2 Scope of delivery _____________________________________________________ 49
7.3 Mains connection ________________________________________________ 49
7.4 Battery power supply _____________________________________________ 49
7.5 Connection of peripheral devices___________________________________ 49
7.6 Initial Commissioning ____________________________________________ 49
7.7 Adjustment with external weight ___________________________________ 50
7.7.1 Models CPB (Non verifiable models) ______________________________________ 50
7.7.2 Models CPB.. M (verifiable models) _______________________________________ 51
7.8 Verification _____________________________________________________ 53
7.8.1 Jumper and seals _____________________________________________________ 54
8 Weighing _____________________________________________________ 55
8.1 Switch on/off and set zero _________________________________________ 55
8.2 Simple weighing _________________________________________________ 55
8.3 Weighing with taring _____________________________________________ 56
8.3.1 Determination of the tare weight by weighing________________________________ 56
9 Parts counting_________________________________________________ 57
9.1 Determination of the reference weight by weighing ____________________ 57
9.2 Numeric entering of the reference weight ____________________________ 59
9.3 Automatic reference optimization___________________________________ 59
9.4 Target piece input________________________________________________ 60
9.5 Manual total memory _____________________________________________ 60
9.6 Automatic total memory___________________________________________ 61
10 Data Interface RS 232C ________________________________________ 62
10.1 Technical data___________________________________________________ 62
10.2 Pin allocation for the balance output socket (front view)________________ 62
10.3 Data format _____________________________________________________ 62
10.4 Interface parameter ______________________________________________ 64
10.5 Input commands format___________________________________________ 65
10.6 Setting the date/time _____________________________________________ 66
11 Display background illumination________________________________ 67
12 AUTO OFF function___________________________________________ 68
13 Service, maintenance, disposal _________________________________ 69
13.1 Cleaning _______________________________________________________ 69
13.2 Service, maintenance_____________________________________________ 69
13.3 Disposal________________________________________________________ 69
14 Instant help _________________________________________________ 70
CPB-BA-defsi-0712
38
1 Technical data
KERN CPB 3K0.1 CPB 6K0.2 CPB 15K0.5 CPB 30 K1
Readability (d) 0,1 g 0,2 g 0,5 g 1 g
Weighing range (max) 3 kg 6 kg 15 kg 30 kg
Reproducibility 0,1 g 0,2 g 0,5 g 1 g
Linearity ± 0,4 g ± 0,8 g ± 1,5 g ± 3 g
Stabilization time 2 sec. 2 sec. 2 sec. 2 sec.
Recommended adjusting weight (not supplied)
3 kg (M1) 5 kg (M1) 10 kg (M1) 20 kg (M1)
Minimum piece weight 0,05 g 0,1 g 0,25 g 0,5 g
Reference quantity freely selectable
Net weight (kg) 4.1 kg
Permissible ambient condition
-10° C to 40° C
Humidity of air 15 % - 85 % (not condensing)
Weighing plate, stainless steel
225 x 275 mm
Dimensions of the housing (B x D x H)
315 x 355 x 110 mm
Mains connection Mains adaptor 230 V, 50/60 Hz ; 9 V DC balance, 800 mA
Battery Operating time ca. 70 hrs. / Charging time ca. 12 hrs.
CPB-BA-defsi-0712
39
KERN CPB 3K1M CPB 6K2M CPB 15K5M CPB 30K10M
Readability (d) 1 g 2 g 5 g 10 g
Weighing range (max) 3 kg 6 kg 15 kg 30 kg
Verification value e 1 g 2 g 5 g 10 g
Class of accuracy III III III III
Reproducibility 1 g 2 g 5 g 10 g
Linearity ± 1 g ± 2 g ± 5 g ± 10 g
Stabilization time 2 sec. 2 sec. 2 sec. 2 sec.
Recommended adjusting weight (not supplied)
2 kg + 1 kg
(F2)
5 kg (F2)
10 kg + 2 kg
(F2)
20 kg + 5 kg
(F2)
Minimum piece weight 0,05 g 0,1 g 0,25 g 0,5 g
Reference quantity freely selectable
Net weight (kg) 4.1 kg
Permissible ambient condition
-10° C to 40° C
Humidity of air 15 % - 85 % (not condensing)
Weighing plate, stainless steel
225 x 275 mm
Dimensions of the housing (B x D x H)
315 x 355 x 110 mm
Mains connection Mains adaptor 230 V, 50/60 Hz ; 9 V DC balance, 800 mA
Battery Operating time ca. 70 hrs. / Charging time ca. 12 hrs.
CPB-BA-defsi-0712
40
2 Declaration of conformity
KERN & Sohn GmbH
D-72322 Balingen-Frommern Postfach 4052 E-Mail: info@kern-sohn.de
Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de
Konformitätserklärungen
Declaration of conformity for apparatus with CE mark
Konformitätserklärung für Geräte mit CE-Zeichen
Déclaration de conformité pour appareils portant la marque CE
Declaración de conformidad para aparatos con marca CE
Dichiarazione di conformitá per apparecchi contrassegnati con la marcatura CE
English
We hereby declare that the product to which this declaration refers conforms with the following standards.
Deutsch
Wir erklären hiermit, daß das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt.
Français
Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après.
Español
Manifestamos en la presente que el producto al que se refiere esta declaración est´´a de acuerdo con las normas siguientes
Italiano
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate.
Electronic Scale: KERN CPB
Mark applied EU Directive Standards
89/336/EEC EMC
73/23/EEC Low Voltage
EN 61326
EN 60950-1 EN 61010
10.01.2007 Signature: Gottl. KERN & Sohn GmbH
Management
Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149
CPB-BA-defsi-0712
41
KERN & Sohn GmbH
D-72322 Balingen-Frommern Postfach 4052 E-Mail: info@kern-sohn.de
Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de
Konformitätserklärungen
Declaration of conformity for apparatus with CE mark
Konformitätserklärung für Geräte mit CE-Zeichen
Déclaration de conformité pour appareils portant la marque CE
Declaración de conformidad para aparatos con marca CE
Dichiarazione di conformitá per apparecchi contrassegnati con la marcatura CE
English
We hereby declare that the product to which this declaration refers conforms with the following standards.
This declaration is only valid with the certificate of conformity by a notified body.
Deutsch
Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt.
Diese Erklärung gilt nur in Verbindung mit der Konformitätsbescheinigung einer benannten Stelle.
Français
Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après.
Cette déclaration est valide seulement avec un certificat de conformité d´un organisme notifié.
Español
Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes.
Esta declaración solo será válida acompañada del certificado de conformidad de conformidad de la parte nominal.
Italiano
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate.
Questa dichiarazione sarà valida solo se accompagnata dal certificato di conformità della parte nominale.
Electronic Scale: KERN CPB…M
EU Directive Standards
EC-type-approval certificate no. Issued by
90/384/EEC EN 45501 TC 7102 / T7104
NMI
Date: 10.01.2007 Signature:
Gottl. KERN & Sohn GmbH Management
Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-07433/9933-0,Fax +49-074433/9933-149
CPB-BA-defsi-0712
42
3 Device overview
RS 232 interface
Air bubble
ON/OFF switch
Mains cable connection
ON/OFF switch
Battery compartment
CPB-BA-defsi-0712
43
3.1 Overview of display
Weight Reference weight Pieces
0.0 0 0
dddddddddd
3.1.1 Display weight
Here, the weight of your goods is displayed in [kg].
The arrows above the symbols show:
Battery very low
NET
Net weight
Stability display
a
Zeroing display
3.1.2 Display reference weight
Here, the reference weight of a sample is displayed in [g]. This value is either entered by user of calculated by balance.
The arrows above the symbols show:
Number of parts placed on balance too small
PRESET
Saved limit value
Reference weight placed on balance too small
3.1.3 Display quantity
Here, all the parts placed on balance are immediately displayed by number.
The arrows above the symbols show:
M
Data in memory
CPB-BA-defsi-0712
44
3.2 Keyboard overview
Choice Function
Number keys
Delete key
Addition in total memory
Call up total memory
Enter/display limit value for tolerance check
Call up menu "Display background illumination"
Output to external device (printer) or PC
Enter reference weight through weighing
Numeric entry reference weight
Function /parameter selection
Taring key
Save
Zeroing key
Back to weighing mode
CPB-BA-defsi-0712
45
4 Basic Information (General)
4.1 Proper use
The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read.
4.2 Improper Use
Do not use balance for dynamic weighings. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.
4.3 Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
mechanical dammage or dammage by media, liquids, natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
CPB-BA-defsi-0712
46
4.4 Monitoring of Test Resources
In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost.
5 Basic Safety Precautions
5.1 Pay attention to the instructions in the Operation Manual
Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.
5.2 Personnel training
The appliance may only be operated and maintained by trained personnel.
6 Transport and storage
6.1 Testing upon acceptance
When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.
6.2 Packaging
Keep all parts of the original packaging in case you need to return the appliance. Only use original packaging for returning. Before sending, disconnect all connected cables and loose/movable parts. Attach possibly existing transport safeguards. Secure all parts, e.g. weighing plate, power unit etc., to prevent slipping and damage.
CPB-BA-defsi-0712
47
Loading...