The MS-3000 MicroStar Reader is intended for installation on a window mullion or a door frame,
on or off metal, in proximity applications where an unobtrusive reader is required. The reader
provides an audible beeper and a multi colored LED to annunciate the reader's status when used
with a PXL-250, PXL-100, or IntelliProx.
•Amber - to indicate normal operation awaiting an access event
•Green - to indicate a valid card has been presented or the door has been unlocked for access
•Red - to indicate an invalid card has been presented or the door is in an alarm condition
The MS-3000 MicroStar Reader is housed in a black, weatherproof, shock resistant package. The
reader provides optimum performance when mounted on aluminum; read range is slightly reduced
if the reader is not mounted on aluminum.
1.0Specifications
1.1Dimensions
•3.25 inches High x 1.41 inches Wide x 0.375 inches Deep
•8.26 cm High x 3.95 cm Wide x 0.96 cm Deep
Figure 1: MS–3000 Dimensions
MS-3000Quick Start Guide
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 1 of 8
MS-3000 MicroStar Reader
1.2Operating Voltage
•5v to 14v DC @ 50 ma
1.3Cable Specifications
•up to 500 feet using six conductor, shielded, stranded AWG 24 wire (such as Belden 9536)
2.0Mounting Instructions
Three holes need to be drilled to mount the MicroStar Reader (see Figure 1). One large hole (0.875"
- 7/8") accommodates the beeper and the reader cable. Two small holes are for mounting the reader
on the mullion or door frame (hole size is dependent upon the size of the mounting screw).
NOTE: Do not mount the reader near sources of Electromagnetic Interference (EMI) such as a
computer monitor. EMI degrades a reader's read range.
Quick Start GuideMS-3000
3.0Connections
The MicroStar Reader does not require configuration; there are no switches or jumpers to set. The
MicroStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be
connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand
input device mode. All connections needed to support the reader are made through the reader's
cable. Please consult the tables on pages 2 and 3 for specific connection instructions.
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 2 of 8
MS-3000 MicroStar Reader
3.1PXL-250 Connections
The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is
made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but no
connection is made to that pin).
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 3 of 8
MS-3000 MicroStar Reader
3.2Design 5 PXL-100 Connections
The "A" reader connects to TB2, pins 14 through 19. The "B" reader to TB3, pins 20 through 25.
Connecting the PXL-100 – TB2Connecting to the PXL-100 – TB3
NOTE: Please contact customer support at Keri Systems for information regarding connecting a
Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its power
connection made at the middle of the left edge of the printed circuit board.
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 4 of 8
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 5 of 8
MS-3000 MicroStar Reader
4.0Installation Verification
The following information applies to an installation with a Keri Systems controller or IntelliProx
unit. When used with an alternative host controller/alarm panel through an IntelliProx used in its
Wiegand input device mode, the actions of the reader's LED and beeper are controlled by the
alternative host controller/alarm panel and might not match those of a Keri Systems controller.
The reader's power is provided by the controller, so the read er is powered on when the controller is
powered on. The reader's normal state is to display a constantly on Amber LED as it waits for a card
or tag to be presented.
To verify the reader is functioning properly, pass a Keri Proximity Card or a Keri Key Tag within a
few inches of the reader. The reader will beep and either the Green or Red LED will flash
(depending upon whether or not the card/tag has been enrolled at the controller) and then return to
steady Amber.
To verify the reader's read range, hold a Keri Proximity Card or a Keri Key Tag parallel to the
Quick Start GuideMS-3000
reader, about 1 foot away and slowly draw the Card/Tag in toward the reader. Note the distance
when the reader recognizes the card. The MicroStar reader's range will be up to 4 inches for a card
and 2 inches for a tag depending upon the installation conditions, the material on which the reader is
mounted, and whether it is a card or a tag being read. Due to the physical size difference between
cards and tags, tags provide approximately 50% less read range than cards.
Refer to the Troubleshooting the Reader Installation section beginning on page 7 if the reader is not
functioning properly.
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 6 of 8
MS-3000 MicroStar Reader
5.0Troubleshooting the Reader Installation
ProblemProbable CauseCorrective Action
The reader does
not recognize a
card/tag (no
beep, no LED
flash).
1. One or more of the
reader's wiring
connections are
incorrect.
2. The reader is not
receiving proper power
from the controller.
3. The reader is mounted
too close to a device that
radiates electromagnetic
interference.
4. A jumper is not set
correctly on the
controller.
•Power down the controller and verify the
wiring connections are correct for the reader/
controller combination per the instructions
provided in the Connections section on pages
2 and 3.
•Verify the voltage supplied to the reader is
between 5 and 14 VDC.
•Devices such as computer monitors radiate
electromagnetic interference that affects read
range. When possible, relocate either the
reader or the device to provide a greater
distance between the two.
•For a PXL-250: Verify there is a jumper
across pins 1 and 2 of JP4 (refer to the
Technical Reference manual for more
information - Keri p/n 01836-001).
•For a PXL-100: If the controllers are using
TAPTM software, verify JP1 on the controller
and the jumper on the Receiver card1 are
installed across both jumper pins. If the
controllers are using DoorsTM software,
verify JP1 on the controller and the Receiver
1
are not installed across both pins
card
(typically the jumper will be installed onto
one of the pins to keep it available).
•For an IntelliProx: Verify there is not a
jumper across pins 1 and 2 of JP1 (typically
the jumper can be installed onto one of the
pins to keep it available).
MS-3000Quick Start Guide
– continued on next page –
1. The receiver board's jumper is on the underside of the board. Gently pull the receiver board away from the
controller, verify the jumper setting is correct per your application, carefully align the connectors on the
receiver board with the pins on the controller, and gently push the receiver board back into place.
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 7 of 8
MS-3000 MicroStar Reader
ProblemProbable CauseCorrective Action
The reader has a
short read range.
Quick Start GuideMS-3000
5. You are using an
incorrect type of card.
6. The reader is unable to
read the card.
1. The reader's controller
is not properly
grounded.
2. The shield wire for the
reader's cable has
opened somewhere
between the reader and
the controller.
3. The reader is mounted
too close to a device that
radiates electromagnetic
interference.
4. The controller is
mounted too close to a
device that radiates
electromagnetic
interference.
•Make sure you are using an access card that
is compatible with the reader.
•Verify there is nothing that can interfere
between the reader and the access card.
•Ensure there is a quality earth ground
connection made to the controller. Refer to
the controller's documentation for specific
information regarding the earth ground
connection.
•Verify the shield line from the controller to
the reader is one continuous, connected line.
Refer to the controller's installation
documentation and verify the shield line is
correctly connected to the controller.
•Devices such as computer monitors radiate
electromagnetic interference that affects read
range. When possible, relocate either the
reader or the device to provide a greater
distance between the two.
•Devices such as computer monitors radiate
electromagnetic interference that affects the
performance of the receiver board on the
controller. When possible, relocate either the
controller or the device to provide a greater
distance between the two.
5. The reader is powered
by a switching power
supply.
2305 Bering Drive01815-001 Rev. H
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.comPage 8 of 8
•Switching power supplies are EMI sources.
Change to a linear, regulated power supply.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.