Keri Systems EntraGuard Gold Titanium Cautions User Manual

EntraGuard Gold/Titanium Cautions
This document lists two cautions of which to be aware when installing an EntraGuard Gold or Titanium unit.
To ensure communication compatibility between host computer and EntraGuard Gold/Titanium unit when communicating via modem, Keri requires that you only use modems that Keri has tested and qualified for communication compatibility.
The following modems have been tested for communication compatibility:
Harmony Model – FB V 1456VQE-R (Keri P/N EXM-56K, external modem)
AOpen Model – FM56EX/2 (external modem)
As other modems are tested and pass qualification, they will be added to Keri’s Recommended Peripherals List. Please check the Keri web site (www.kerisys.com – Downloads > Technical Documents page) for the current Recommended Peripherals list.

2.0 Drilling the Unit Enclosure

If you are drilling the rear of the enclosure to accommodate a custom mounting requirement, you must be aware of the metal shavings created by drilling which can short out and severely damage the unit’s circuit boards. Perform the following to prevent this type of damage:
1. Disconnect cabling between unit front panel and internal circuit board.
2. Remove the unit’s front panel.
3. Remove the internal circuit board.
4. Drill your custom mounting holes.
5. Thoroughly clean out all metal shavings.
6. Reinstall the internal circuit board and front panel.
7. Reconnect the front panel/circuit board cabling.
NOTE: Insure there is sufficient clearance between the circuit board and housing. Failure to do so may lead to catastrophic board failure.
EntraGuard Gold/TitaniumReference Document
1530 Old Oakland Road, Suite 100 01915-001 Rev. 2.0 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 1 of 2
EntraGuard Gold/Titanium Cautions
Reference DocumentEntraGuard Gold/Titanium
End of document.
1530 Old Oakland Road, Suite 100 01915-001 Rev. 2.0 San Jose, CA 95112 USA (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 2 of 2