Congratulations on your purchase of the EntraGuard Bronze Telephone Entry access
control unit.
For your convenience, this unit has been pre-programmed with the following
parameters for an easy installation. Keep this record for future reference.
1. The Ring Mode has been set to generate two medium length rings followed by a
long pause.
2. The Maximum number of rings has been set to 6.
3. The Programming Code has been set to
4. Four Entry Codes have been set. Keri Systems recommends using one Code for
family members and the others for those individuals who may need access
through the secured area.
1._________________
2._________________
3._________________
4._________________
_____________.
Telephone EntryResidence Guide
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 1 of 14
EntraGuard Bronze
Residence GuideTelephone Entry
This page is intentionally left blank.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 2 of 14
EntraGuard Bronze
This guide is designed to assist residents in programming and using the EntraGuard Bronze
Residential Telephone Entry System. For more detailed information or questions contact your
installer.
1.0Standard Operation
There are six standard operating modes used by the EntraGuard Bronze telephone entry system.
•Visitor Call – when an arriving visitor requests entry.
•Call Waiting – if you are already on the telephone when a visitor entry request is made.
•Call Forwarding – designating a telephone number to which an entry request is routed when you
know you will not be home.
•Remote Connection – allows you to connect to the EntraGuard Bronze unit from the residence
telephone and program the unit.
•Gate Operation from the EntraGuard Bronze Unit – allows you to directly operate a gate from
the EntraGuard Bronze.
•Gate Operation from the Residence Telephone – allows you to directly operate a gate from the
residence telephone.
1.1Visitor Call
The Visitor Call command allows an arriving visitor to request entry by calling the residence
telephone through the EntraGuard Bronze unit.
1. An arriving visitor notifies the residence by pressing the “Call” key.
2. The residence telephone rings with the programmed ring pattern and number of rings.
3. When the residence telephone is answered, it connects to the EntraGuard Bronze unit and
conversation can begin.
4. The connection is automatically disconnected after a programmed amount of time (the default
time is 1 minute). The unit sounds a brief tone to warn both parties with a 3 second warning of
the impending disconnection.
5. The connection time can be extended on the residence telephone by pressing the key.
6. Communication can be terminated immediately and entry denied at any time by pressing the
key.
7. Communication can be terminated immediately and entry granted (by opening the gate) by
entering the desired gate activation code on the residence telephone keypad. When the code is
entered, communication with the unit is terminated and the desired gate relay is activated for the
programmed amount of time.
Telephone EntryResidence Guide
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 3 of 14
EntraGuard Bronze
1.2Call Waiting
If a visitor attempts to notify the residence and the residence telephone is busy, the EntraGuard
Bronze generates a call waiting signal consisting of two, short, high-pitched beeps at three-second
intervals.
1. To put the original call on hold and respond to the EntraGuard Bronze unit, the residence
telephone user presses the key.
2. Once the connection to the EntraGuard Bronze is ended, the residence telephone automatically
reconnects to the call on hold.
1.3Call Forwarding
If the Call Forwarding feature is enabled, the EntraGuard Bronze dials a programmed remote
telephone number instead of the residence telephone. If the remote number is busy, the EntraGuard
Bronze unit disconnects immediately.
Residence GuideTelephone Entry
1.4Remote Connection
Remote Connection allows you to program the EntraGuard Bronze unit from the residence
telephone.
1. The residence telephone can connect to the EntraGuard Bronze at any time by pressing the
key three times with a brief delay between key presses.
2. Once connected, you must enter programming mode (see Section 2.1 on page 6) and then you
can begin programming the EntraGuard Bronze unit.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 4 of 14
EntraGuard Bronze
1.5Gate Operation From The EntraGuard Bronze Unit
The Gate Operation from the EntraGuard Bronze Unit command allows you to immediately open a
gate from the Bronze unit.
•To open Gate 1 from the EntraGuard Bronze unit, press , press , and press the user’s
three-digit entry code.
•To open Gate 2 from the EntraGuard Bronze unit, press , press , and press the user’s
three-digit entry code.
•If a code entry mistake is made, the user can cancel the entry by pressing the key at any
time.
EXAMPLE: Enter the following to open Gate 1 from the EntraGuard Bronze unit with a user entry
code of “212.”
1.6Gate Operation From The Residence Telephone
Gate Operation from the Resident Telephone command allows you to immediately open a gate from
the residence telephone.
•To connect the residence telephone to the EntraGuard Bronze unit for gate operation, press
three times with a brief delay between key presses.
•To open Gate 1 from the EntraGuard Bronze unit, press , press , and press the user’s
three-digit entry code.
•To open Gate 2 from the EntraGuard Bronze unit, press , press , and press the user’s
three-digit entry code.
•If a code entry mistake is made, the user can cancel the entry by pressing the key at any
time.
EXAMPLE: Enter the following to open Gate 1 from the residence telephone with a user entry code
of “212.”
Telephone EntryResidence Guide
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 5 of 14
EntraGuard Bronze
2.0Programming
All operating parameters are programmable from either the EntraGuard Bronze’s front panel
keypad or from any telephone in the residence connected to the same phone line as the EntraGuard
Bronze unit. There are 19 commands available.
When entering programming commands, the unit responds to correct entries with a short, highpitched tone to indicate the command was accepted. The unit responds to incorrect/invalid entries
with a short, high-pitched tone followed by a low-pitched tone to indicate the command was
rejected.
2.1Entering and Exiting Programming Mode
The EntraGuard Bronze unit must be in programming mode to set any of the unit’s operating
parameters.
2.1.1Entering Programming Mode from the Bronze Unit:
Residence GuideTelephone Entry
1. Press the key three times.
2. Enter the six-digit pre-programmed code (see page 1 for the code assigned to this unit, the
factory default is “999999”).
3. The unit emits a short high-pitched tone to indicate the code was accepted. For security reasons,
the unit does not emit any sounds to indicate if an incorrect code has been entered.
EXAMPLE: Enter the following to enter a Programming Code of “135246.”
2.1.2Entering Programming Mode from the Residence Telephone
1. Press the key three times.
2. Enter the six-digit programming code (see page 1 for the code assigned to this unit, the factory
default is “999999”).
3. The unit emits a short high-pitched tone to indicate the code was accepted. For security reasons,
the unit does not emit any sounds to indicate if an incorrect code has been entered.
EXAMPLE: Enter the following to enter a Programming Code of “135246.”
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 6 of 14
EntraGuard Bronze
2.1.3Exiting Programming Mode
When programming from the EntraGuard Bronze unit, the unit exits programming mode after 1
minute of keypad inactivity. To exit programming mode immediately after entering a programming
command, press .
To exit programming mode when using the residence telephone, press or simply hang up.
2.2Set Programming Mode Entry Code
To increase system security, you have the option to change the code number required to enter
programming mode from its pre-programmed setting.
NOTE: To ensure the security of your EntraGuard Bronze system, Keri Systems strongly
recommends that you perform this command at any time you feel the Programming Code has been
discovered by someone who should not have it.
This code number must be six-digits long. For security reasons, certain consecutive strings of
numbers are not accepted; for example, “123456” is not accepted. Perform the following to set the
programming mode entry code.
1. Press .
2. Enter the desired six-digit programming mode entry code – .
3. Press to lock in the new programming mode entry code. The unit emits a short, highpitched tone to indicate the new code has been accepted. The unit emits a short, high-pitched
tone followed by a low-pitched tone if the programming mode entry code has been rejected.
EXAMPLE: Enter the following to set a Programming Mode Entry Code of “135246.”
4. You can now enter another program command or press to exit programming mode.
Telephone EntryResidence Guide
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 7 of 14
EntraGuard Bronze
2.3Program Commands
Once in programming mode, you can change any of the EntraGuard Bronze’s programmable
commands. The general process for changing an existing command value is as follows:
1. Enter the two-digit programming command code for the command you wish to change.
2. If applicable, enter the new value (some commands simply enable or disable a feature and do
not have an associated value).
-If an entry error has been made, press and start again from Step 1.
3. Press to lock in the change.
-If the entry is valid, the unit emits a short, high-pitched tone to indicate the change has been
accepted.
-If the entry is invalid, the unit emits a short, high-pitched tone followed by a low-pitched
tone to indicate the change has been rejected.
4. Return to Step 1 to enter another program command change, or to exit programming mode,
Residence GuideTelephone Entry
either press or hang up (if using the residence telephone).
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 8 of 14
EntraGuard Bronze
3.0Table of Programming Commands
Programming commands can be performed at the EntraGuard Bronze unit or the residence
telephone.
Programming CommandInstructions
Enter Programming Mode
•Press .
From the Bronze Unit
•Press – the six-digit
programming code (see page 1 for pre-programmed setting,
the factory default is “999999”).
•The unit emits a short high-pitched tone to indicate the unit is
in programming mode. If no sound is emitted an invalid
programming code has been entered.
Enter Programming Mode
•Press .
From the Residence
Telephone
•Press – the six-digit
programming code (see page 1 for pre-programmed setting,
the factory default is “999999”).
•The unit emits a short high-pitched tone to indicate the unit is
in programming mode. If no sound is emitted an invalid
programming code has been entered.
Telephone EntryResidence Guide
All subsequent commands assume the EntraGuard Bronze unit is in Programming Mode.
SET THE
PROGRAMMING MODE
ENTRY CODE
Sets the entry code used to
enter program parameters.
•Press .
•Press – the desired six-digit
programming code (see page 1 for pre-programmed setting,
the factory default is “999999”).
•Press . The unit emits a short high-pitched tone to
indicate the entry code has been accepted. A high-low tone is
emitted if an invalid entry code has been entered.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 9 of 14
EntraGuard Bronze
Programming CommandInstructions
ADD AN ENTRY CODE
•Press .
An Entry Code allows a user
to activate a gate relay from
the EntraGuard Bronze unit.
DELETE AN ENTRY
CODE
•Press – the desired entry code (see page 1 for
the four pre-programmed codes, the factory default is ”123”).
•Press . The unit emits a short high-pitched tone to
indicate the code has been accepted. A high-low tone is
emitted if an invalid programming code has been entered.
•Press .
Deletes a users entry code.
Residence GuideTelephone Entry
DELETE ALL ENTRY
CODES
Deletes ALL user entry
codes.
RESET THE
ENTRAGUARD BRONZE
UNIT
Resets all programmable
values (except for the
programming entry code) to
the factory default value
a
•Press – the entry code to be deleted.
•Press . The unit emits a short high-pitched tone to
indicate the code has been deleted. A high-low tone is
emitted if an invalid entry code has been entered.
•Press .
•Press . The unit emits a short high-pitched tone to
indicate all entry codes have been deleted. A high-low tone is
emitted if an invalid entry code has been entered.
•Press .
•Press . The unit emits a short high-pitched tone to
indicate the unit has been reset.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 10 of 14
EntraGuard Bronze
Programming CommandInstructions
SET THE RING MODE
•Press .
Sets the ring pattern used
when a visitor requests entry.
SET THE MAXIMUM
NUMBER OF RINGS
•Select the desired ring mode (default = 1).
-Press for three short rings - long pause
-Press for two medium rings - long pause
•Press . The unit emits a short high-pitched tone to
indicate the ring mode has been accepted. A high-low tone is
emitted if an invalid ring mode has been entered.
•Press .
Sets the maximum number of
rings used when a visitor
requests entry.
SET GATE 1 RELAY
ACCESS CODE
Allows a user to activate the
gate 1 relay from the
residence telephone.
SET GATE 1 RELAY
TIMEOUT
Sets the amount of time the
gate 1 relay is activated.
•Press – the desired number of rings (default = 6).
•Press . The unit emits a short high-pitched tone to
indicate the number of rings has been accepted. A high-low
tone is emitted if an invalid number of rings has been entered.
•Press .
Telephone EntryResidence Guide
•Press – the desired relay access code (default = 9).
•Press . The unit emits a short high-pitched tone to
indicate the access code has been accepted. A high-low tone
is emitted if an invalid access code has been entered.
•Press .
•Press – the desired relay timeout value (default = 5
seconds).
•Press . The unit emits a short high-pitched tone to
indicate the timeout value has been accepted. A high-low
tone is emitted if an invalid timeout value has been entered.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 11 of 14
EntraGuard Bronze
Programming CommandInstructions
SET GATE 2 RELAY
ACCESS CODE
•Press .
Allows a user to activate the
gate 2 relay from the
residence telephone.
SET GATE 2 RELAY
TIMEOUT
Sets the amount of time the
gate 2 relay is activated.
Residence GuideTelephone Entry
SET CALL
FORWARDING
TELEPHONE NUMBER
Sets an alternate telephone
number to which entrance
request calls can be
forwarded.
•Press – the desired relay access code (default = 2).
•Press . The unit emits a short high-pitched tone to
indicate the access code has been accepted. A high-low tone
is emitted if an invalid access code has been entered.
•Press .
•Press – the desired relay timeout value (default = 5
seconds).
•Press . The unit emits a short high-pitched tone to
indicate the timeout value has been accepted. A high-low
tone is emitted if an invalid timeout value has been entered.
•Press .
•Press – the desired
forwarding telephone number (up to 20 digits).
•Press . The unit emits a short high-pitched tone to
indicate the telephone number has been accepted. A high-low
tone is emitted if an invalid telephone number has been
entered.
ENABLE CALL
FORWARDING
Enables the call forwarding
feature.
DISABLE CALL
FORWARDING
Disables the call forwarding
feature.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 12 of 14
•Press .
•Press . The unit emits a short high-pitched tone to
indicate call forwarding has been enabled.
•Press .
•Press . The unit emits a short high-pitched tone to
indicate call forwarding has been disabled.
EntraGuard Bronze
Programming CommandInstructions
SET MAXIMUM
CONNECTION TIME
•Press .
Sets the maximum amount of
time the telephone line is
active when a visitor
requests entry.
HOLD OPEN GATE 1 –
FIXED PERIOD OF
TIME
Immediately holds the gate 1
relay open for a finite period
of time.
HOLD OPEN GATE 1 –
INDEFINITELY
Immediately holds the gate 1
relay open indefinitely.
•Press – the desired maximum connection time
(default = 60 seconds).
•Press . The unit emits a short high-pitched tone to
indicate the connection time has been accepted. A high-low
tone is emitted if an invalid connection time has been
entered.
•Press .
•Press – the desired maximum connection time, in
minutes.
•Press . The unit emits a short high-pitched tone to
indicate the gate hold open time has been accepted. A highlow tone is emitted if an invalid gate hold open time has been
entered.
•Press .
•Press . The unit emits a short high-pitched tone to
indicate the gate hold open time has been accepted.
Telephone EntryResidence Guide
CLOSE GATE 1
Immediately closes the gate
1 relay.
•Press .
•Press . The unit emits a short high-pitched tone to
indicate the close command has been accepted.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 13 of 14
EntraGuard Bronze
Programming CommandInstructions
HOLD OPEN GATE 2 –
FIXED PERIOD OF
TIME
Immediately holds the gate 2
relay open for a finite period
of time.
HOLD OPEN GATE 2 –
INDEFINITELY
•Press .
•Press – the desired maximum connection time, in
minutes.
•Press . The unit emits a short high-pitched tone to
indicate the gate hold open time has been accepted. A highlow tone is emitted if an invalid gate hold open time has been
entered.
•Press .
Immediately holds the gate 2
Residence GuideTelephone Entry
relay open indefinitely.
CLOSE GATE 2
Immediately closes the gate
2 relay.
a. Sometimes it is necessary to reset the Bronze unit’s microprocessor which resets the unit to factory defaults
(including the programming entry code). This means any pre-programming done by Keri Systems will be
erased. To perform a complete reset, turn unit power OFF. Press and hold the and keys while
turning the power ON. Release the and keys. The unit is now reset to facotry default values.
•Press . The unit emits a short high-pitched tone to
indicate the gate hold open time has been accepted.
•Press .
•Press . The unit emits a short high-pitched tone to
indicate the close command has been accepted.
1530 Old Oakland Road, Suite 10001911-003 Rev. C
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: sales@kerisys.comPage 14 of 14