KEPCO KRWL User Manual

Page 1
INSTRUCTION MANUAL
KEPCO
An ISO 9001 Company.
DIN-RAIL MOUNTING KIT
FOR SERIES KRW-L
DESCRIPTION. Kepco Kit, Model DIN KRW-L, contains a preassembled mount-
ing frame, a cover, a cable kit and associated hardware (see Table 1) used to install KRW Series power supplies on a DIN rail. The “L” suffix is for mounting along the long dimension (length) as shown in Figure 1. Outline dimensions are shown in Figure 4.
INSTALLING KIT. Install the power supply in the preassembled mounting frame using the hardware supplied (see Figure 3). Then engage the tabs (A) of the cover in the corresponding slots and slide the cover as shown in Figure 3 until the power supply mounting holes (B) are aligned with corresponding holes in the cover. Secure the cover to the mounting frame using the hardware supplied. Attach wires to the power supply per Instruction Sheet supplied with cable kit.

TABLE 1. COMPONENTS SUPPLIED

COVER
PART
NO.
CABLE KIT
PART NO.
SCREW (QTY 8)
(Power Supply and Clips
To Mounting Frame)
PART NO.
WAS HE R (Q TY 8 )
(Power Supply and
Clips To Mounting
Frame)
PART NO.
CLIP
(QTY 2)
PAR T
NO.
KIT
DIN KRW-L

FIGURE 1. L SUFFIX ORIENTATION

CLIP
PLATE
(QTY 2)
PART NO.
(Cover To Mounting Frame)
SCREW (QTY 2)
PART NO.
CA 29 219-0242
501-0017
(M3 X 6, PHPH)
103-0014
(NO. 4, INT. TOOTH)
108-0366 128-1996
101-0443
(4-40 X 1/4 BHPH)
INSTALLING POWER SUPPLY ON DIN RAIL. To mount the power supply on the rail insert one end of the clip under one edge of the rail, then snap the other end of the clip into place (see Figure 2A).
REMOVING POWER SUPPLY FROM DIN RAIL. While grasping the power supply with one hand, use a screwdriver to apply leverage towards the left as shown in Figure 2B to disengage the clip from the rail.
INSTALLATION
A -

FIGURE 2. INSTALLATION AND REMOVAL OF POWER SUPPLY FROM DIN RAIL

B -
REMOVAL
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
http://www.kepcopower.com " email: hq@kepcopower.com
©1999, KEPCO, INC Data subject to change without notice 228-1374
1
Page 2

FIGURE 3. INSTALLATION OF KIT ON KRW POWER SUPPLY

FIGURE 4. KRW POWER SUPPLY WITH KIT INSTALLED, OUTLINE DIMENSIONS

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
2
http://www.kepcopower.com " email: hq@kepcopower.com
228-1374 061901
FAX (718) 767-1102
Loading...