INSTRUCTION SHEET
KEPCO
An ISO 9001 Company.
CABLE
KIT
CABLE KIT NO. 219-0449
BOP 1000W MODELS (2) IN PARALLEL
This kit contains the cables and terminations required to operate two identical 1000 Watt BOP High Power models in parallel, effectively multiplying the output current capacity by two. Only identical models may be configured
to operate in parallel.
This kit can be used with all 1000W BOP models that have revision levels as shown in Table 1. Earlier models
!
that have been upgraded to permit multiple unit configurations must include the letter “A” following the revision
number. CAUTION: Failure to install the ground cables supplied can result in damage to the power supply.
Refer to the associated technical manual supplied with the 1000W BOP power supply for all instructions regarding installation and operation of multiple units in parallel.
TABLE 1. REVISION LEVELS APPLICABLE TO THIS KIT
MG Model Revision
BOP 6-125MG All All
BOP 10-75MG 5 or higher 3A or 4A
BOP 20-50MG 8 or higher 5A, 6A or 7A BOP 20-50GL All
BOP 25-40MG All All
BOP 36-28MG 11 or higher 8A, 9A or 10A
BOP 50-20MG 7 or higher 5A or 6A BOP 50-20GL All
BOP 72-14MG 7 or higher 6A
BOP 100-10MG 6 or higher 2A or 4A
Revisions for previously Upgraded
Units (Must include “A”)
GL Model Revision
219-0449
I. SPECIFICATIONS
Table 3 lists the model parameters unique to a parallel combination of two identical 1000W BOP Power Supplies.
Table 4 lists the general specifications for the parallel combinations listed in Table 3. For specifications not listed
in Table 3, refer to the General Specifications provided in the associated technical manual supplied with each
1000W BOP power supply
Item Quantity Purpose
Common power cable **
Master - IN Parallel Control
** For GL units: Unclamp and remove ferrite from cable before installation.
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
©2012, KEPCO, INC
Data subject to change without notice
(1.5 ft.)
Output Power cable
(1.5 ft.)
Digital Control (Bitbus)
Cable ** (1.5 ft.)
Parallel Control Cable
(1.5 ft.)
Protection Cable
(1 ft.)
Termination
TABLE 2. EQUIPMENT SUPPLIED
Connects the COMMON terminal of the Master to the COMMON terminal of the
1
Slave #1.
Connects the OUTPUT terminal of the Master to the OUTPUT terminal of the
1
Slave #1.
Provides communication between master and slave. 118-1108
1
Provides control signals required for parallel operation. 118-1119
1
Provides interlock protection signals required for multiple unit operation. 118-1126
1
1 Provides proper termination for Parallel Control Cable. 195-0109
http://www.kepcopower.com email: hq@kepcopower.com
228-1485 REV 7 051812
Kepco Part
Number
118-1129
118-1112

TABLE 2. EQUIPMENT SUPPLIED (CONTINUED)
Item Quantity Purpose
Protection - OUT Termination
1 Provides proper termination for the slave connection to the Protection Cable. 195-0108
Kepco Part
Number
(Slave)
Protection - IN Termination
(Master)
1 Provides proper termination for the master connection to the Protection Cable. 195-0107
Chassis Ground Cable 1 Connects chassis ground terminals of all units. 118-1272
Ground Cable mounting
hardware
2 sets Each set consists of eight parts, mounted in the following order: No. 10 star
lockwasher P/N 103-0106 (at chassis), No. 10 flat washer P/N 103-0031, No. 10
split lockwasher P/N 103-0033, 10-32X3/8 nut P/N 102-0008, No. 10 flat washer
P/N 103-0031, [lug(s) from ground cable], No. 10 flat washer P/N 103-0031, No.
(See
Purpose
at left for
part
numbers)
10 split lockwasher P/N 103-0033, and 10-32X3/8 nut P/N 102-0008.
Instruction
Manual
Nut 2 Overcomes tight space for output cable connections. After securing bottom
1 Lists material supplied. 228-1485
102-0046
cable to output terminal stud using one nut, additional cables can be oriented
for best layout and secured with separate nut.
II. SPECIFICATIONS
Table 3 lists the model parameters unique to a parallel combination of two 1000W BOP Power Supplies. Table 4
lists the general specifications applicable all the parallel combinations listed in Table 3.
TABLE 3. MODEL PARAMETERS FOR TWO (2) HIGH POWER BOP 1000 WATT UNITS (PARALLEL)
(2) Identical Models
(Parallel)
BOP 6-125MG ±6V d-c ±250A d-c 0.6 25.0
BOP 10-75MG ±10V d-c ±150A d-c 1.0 15.0
BOP 20-50MG ±20V d-c ±100A d-c 2.0 10.0
BOP 25-40MG ±25V d-c ±80A d-c 2.5 8.0
BOP 36-28MG ±36V d-c ±56A d-c 3.6 5.6
BOP 50-20MG ±50V d-c ±40A d-c 5.0 4.0
BOP 72-14MG ±72V d-c ±28A d-c 7.2 2.8
BOP 100-10MG ±100V d-c ±20A d-c 10.0 2.0
d-c Output Range Closed Loop Gain
E
O Max
I
O Max
Voltage Channel
(V/V)
Current Channel
(A/V)
TABLE 4. GENERAL SPECIFICATIONS FOR TWO (2) IDENTICAL BOP 1000 WATT UNITS (PARALLEL)
SPECIFICATION RATING/DESCRIPTION CONDITION
INPUT CHARACTERISTICS
Current 176 Va-c 19.0A a-c maximum
264 Va-c 13A a-c maximum
Leakage current 7mA a-c 230V a-c, 47-63 Hz
OUTPUT CHARACTERISTICS
Programming
resolution / accuracy
Voltage 14 bits / 0.2% 2% accuracy for Ext Ref Level. Unit gain
Current 14 bits / 0.5%
adjustable between 0 and E
or I
ONOM
/10 (current).
ONOM
/10 (voltage)
Voltage Limit 12 bits / 0.5%
Current Limit 12 bits / 0.5%
Readback
resolution / accuracy
Voltage 16 bits / 0.2% main or limit channel
Current 16 bits / 0.5% main or limit channel
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000