
INSTRUCTION SHEET
KEPCO
An ISO 9001 Company.
CABLE
KIT
219-0443
CABLE KIT NO. 219-0443
BOP 1000W MODELS (2) IN SERIES
I. DESCRIPTION.
This kit contains the cables and terminations required to operate two identical 1000 Watt BOP High Power models in series, effectively doubling the output voltage capacity. Only identical models may be configured to operate
in series.
This kit can be used with all 1000W BOP models that have revison levels as shown in Table 1. Earlier models that
!
have been upgraded to permit multiple unit configurations must include the letter “A” following the revison number.CAUTION: Failure to install the ground cables supplied can result in damage to the power supply.
Refer to the associated technical manual supplied with the High Power BOP power supply for all instructions
regarding installation and operation of multiple units in series.
TABLE 1. REVISION LEVELS APPLICABLE TO THIS KIT
Model Revision
BOP 6-125MG All All
BOP 10-75MG 5 or higher 3A or 4A
BOP 20-50MG 8 or higher 5A, 6A or 7A
BOP 25-40MG All All
BOP 36-28MG 11 or higher 8A, 9A or 10A
BOP 50-20MG 7 or higher 5A or 6A
BOP 72-14MG 7 or higher 6A
BOP 100-10MG 6 or higher 2A or 4A
Revisions for Upgraded Units
(Must include “A”)
II. SPECIFICATIONS
Table 3 lists the model parameters unique to a series combination of two identical 1000W BOP Power Supplies.
Table 4 lists the general specifications for the series combinations listed in Table 3. For specifications not listed in
Table 3, refer to the General Specifications provided in the associated technical manual supplied with each
1000W BOP power supply
Item Quantity Purpose
Output Power cable
(1.5 ft.)
Digital Control (Bitbus)
Cable (1 ft)
Protection Cable
(1 ft.)
Series Control cable
(1.5 ft.)
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
©2012, KEPCO, INC
Data subject to change without notice
TABLE 2. EQUIPMENT SUPPLIED
Kepco Part
Number
1
1 Provides communication between master and slave. 118-1108
1
1 Provides control signals required for series operation. 118-1120
http://www.kepcopower.com email: hq@kepcopower.com
Connects the OUTPUT terminal of Master to the COMMON
terminal of Slave #1.
Provides interlock protection signals required for multiple unit
operation.
228-1486 REV 2 033012
118- 1112
118-1126

TABLE 2. EQUIPMENT SUPPLIED (CONTINUED)
Item Quantity Purpose
Protection - OUT
Termination (Slave)
Protection - IN
Termination (Master)
1
1
Provides proper termination for the slave connection to the
Protection Cable.
Provides proper termination for the master connection to the
Protection Cable.
Chassis Ground Cable 1 Connects chassis ground terminals of all units.
Ground Cable mounting
hardware
2 sets Each set consists of eight parts, mounted in the following order:
No. 10 star lockwasher P/N 103-0106 (at chassis), No. 10 flat
washer P/N 103-0031, No. 10 split lockwasher P/N 103-0033, 1032X3/8 nut P/N 102-0008, No. 10 flat washer P/N 103-0031,
[lug(s) from ground cable], No. 10 flat washer P/N 103-0031, No.
10 split lockwasher P/N 103-0033, and 10-32X3/8 nut P/N 102-
0008.
Output Sense Cable 1
Instruction Manual 1
Connects Output sense terminal to Common sense terminal of
next unit.
Lists material supplied and specifications for multiple unit
combination.
TABLE 3. MODEL PARAMETERS FOR TWO (2) IDENTICAL BOP 1000 WATT UNITS (SERIES)
(2) Identical Models
(Series)
BOP 6-125MG ±12V d-c ±125A d-c 1.2 12.5
d-c Output Range Closed Loop Gain
E
O Max
I
O Max
Voltage Channel
(V/V)
Current Channel
(A/V)
Kepco Part
Number
195-0108
195-0107
118-1272
(See
Purpose
at left for part
numbers)
118-1271
228-1486
BOP 10-75MG ±20V d-c ±75A d-c 2.0 7.5
BOP 20-50MG ±40V d-c ±50A d-c 4.0 5.0
BOP 25-40MG ±50V d-c ±40A d-c 5.0 4.0
BOP 36-28MG ±72V d-c ±28A d-c 7.2 2.8
BOP 50-20MG ±100V d-c ±20A d-c 10.0 2.0
BOP 72-14MG ±144V d-c ±14A d-c 14.4 1.4
BOP 100-10MG ±200V d-c ±10A d-c 20.0 1.0
TABLE 4. GENERAL SPECIFICATIONS FOR TWO (2) IDENTICAL BOP 1000 WATT UNITS (SERIES)
SPECIFICATION RATING/DESCRIPTION CONDITION
INPUT CHARACTERISTICS
Current 176 Va-c 19A a-c maximum
264 Va-c 12.8A a-c maximum
Leakage current 7mA a-c 230V a-c, 47-63 Hz
OUTPUT CHARACTERISTICS
Programming
resolution / accuracy
Readback
resolution / accuracy
Voltage 14 bits / 0.2% 2% accuracy for Ext Ref Level. Unit gain
Current 14 bits / 0.5%
adjustable between 0 and E
(voltage) or I
ONOM
/10 (current).
ONOM
Voltage Limit 12 bits / 0.5%
Current Limit 12 bits / 0.5%
Voltage 16 bits / 0.2% main or limit channel
Current 16 bits / 0.5% main or limit channel
/10
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000
FAX (718) 767-1102 email: kepcopower@aol.com
2 228-1486 REV 2 033012