DESCRIPTION. The Kepco Model CA 33 Cover (see Figure 1) is supplied for use with Kepco Series RKW 30 Watt
power supplies. The cover is installed by first removing two screws (M3 X 8) from the RKW power supply (see Figure
1). Then slide the cover onto the power supply, matching the tabs as shown in Detail A, and secure with screws previously removed. This screw must not be overtightened (max. torque 10 in.- lbs (1.1 N x m).
REMOVE EXISTING SCREWS (M3 x 8) FROM
RKW POWER SUPPLY AND USE TO SECURE
COVER TO POWER SUPPLY.
MAX TORQUE 10 1N.-LBS (1.1N x m)
RKW TAB
SEE DETAIL A
CA 33 COVER
COVER TAB
COVER TAB
SEE DETAIL A
RKW TAB
DETAIL A
3042593-1
FIGURE 1. CA 33 COVER INSTALLATION
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
http://www.kepcopower.com " email: hq@kepcopower.com
©2005, KEPCO, INC 1
Data subject to change without notice 228-1473 REV 1
RKW 30W POWER SUPPLY

0.226 ±0.015 (5.74 ±0.381)
0.374 ±0.015 (9.5 ±0.381)
0.22
(5.59)
0.137 (3.48) TYP.
0.136
(3.45)
4.32 (109.73)
4.500 ±0.015 (114.3 ±0.381)
4.720 ±0.015 (119.89 ±0.381)
0.575 ±0.015 (14.60 ±0.381)
1.205 ±0.015
(30.61 ±0.381)
0.40
0.136
(3.45)
0.16
(4.06)
1.08
(27.43)
3042641
0.275 (6.99) TYP.
0.20 (5.08)
0.377 (9.58)
4.880 ±0.015 (123.952 ±0.381)
3.832 ±0.015 (92.333 ±0.381)
3.497 ±0.015 (88.824 ±0.381)
1.275 ±0.015 (3.2 ±0.381)
0.144 (3.66)
0.20 (5.08)
0.45 (11.43) TYP.
0.95
(24.13)
2.925 ±0.015
(74.30 ±0.381)
2.361
±0.015
(59.97
±0.381)
0.144 ±0.015 (3.653 ±0.381)
NOTES:
1. MATERIAL: 0.024 (0.6)
GALVANIZED STEEL.
2. DIMENSIONS ARE IN INCHES,
DIMENSIONS IN
PARENTHESES ARE IN
MILLIMETERS.
3. TOLERANCES: ±0.04 (±1)
UNLESS OTHERWISE
SPECIFIED.
FIGURE 2. CA 33 OUTLINE DIMENSIONS
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
http://www.kepcopower.com " email: hq@kepcopower.com
2 228-1473 REV 1 071905