XHV Series
Features:
• Available for 1/8 DIN and DIN 144 x 72 mm
Cases
• Meets NEMA 7 & 4 Specs.
• For use in Class 1, Division 1, Groups C & D
•For use in Class 2 & 3, Division 1,
Groups E, F & G
• UL, cUL Approved
• Magnetic Reset Switch Available
Specifications:
This housing is designed and manufactured in compliance with UL Standard No. 1203 and was investigated to
CSA Standard C22.2 No. 30-M1986 by UL for use in
Class 1, Division 1, Groups C & D and Class II & III,
Division I, Groups E, F & G hazardous locations.
Certified by:
ADALET
UL (file# E81696 )
X-Proof Housing for Viewing
Displays in Hazardous Areas
Dimensions:
6.25
(158.8)
The housing is made from cast aluminum and sealed
to meet NEMA 7 and 4 specifications.
To install a unit, the cover must be removed and the
KEP unit mounted in the sub panel provided.
Empty weight:
XHV = 19 lbs.
XHVD = 22 lbs.
Ordering Information
Example: XHV 7/4 A A S1
Series:
XHV 7/4 (8.5" high for INT69, MRT, Reporter, etc.)
XHVD 7/4 (11.5" high for SUPERtrol 1 and 2, LEVELtrol II)
Mounting Sub Panel:
A = Panel for (1) 1/8 DIN unit (INT69, MRT, etc.)
B = Panel for (2) 1/8 DIN units (INT69, MRT, etc.)
C = Panel for (1) DIN 144 x 72mm unit (ST1, ST2, LT2, Reporter)
Assembly By KEP:
A = Assembled by KEP
X = No Assembly
ACCESSORIES
Flow Instruments
Options:
S1 = 1 Magnetic Reset Switch and Magnet
S2 = 2 Magnetic Reset Switches and Magnet
Accessories:
XHVA-1 = Magnetic Switch
XHVA-2 = Actuating Magnet
10.5
(266.7)
7.75
H
(196.9)
6.75
(171.5)
7.75
(196.9)
3.25
(82.6)
2.25
(57.2)
9.125
(231.8)
1/2" - 14 NPT Plugs
(2 Places)
2.25
(57.2)
Note: When placing the order, the unit part number directly
following the XHV part number on the Purchase Order is the
one that will be assembled into the XHV housing.
Page 114 • Flow Instruments • F-15 Kessler-Ellis Products • 800-631-2165
XHV = 8.5 (215.9)
XHVD = 11.5 (292.1)
H