KEP SC-IF Data sheet

SC-IF SERIES
Features
• 4-20 mA Input (10-50 mA optional)
•0 to 10 kHz Pulse Output
• Two Year Warranty
• Loop Powered
• Input & Output LED Indicators
• Various Mounting Styles
Current to Frequency Loop Powered Isolator
SIGNAL CONDITIONERS
Flow Instruments
Description:
The SC-IF loop powered signal conditioner whose function is to provide a 0 - 10kHz frequency output signal in response to a 4­20mA analog input.
The SC-IF appears to the input loop as a series shunt resistor. A small sense resistor is used to measure the input current. The input loop derives it’s power from the input current loop.
This input current signal is then scaled and converted to a 0 to 10,000 Hz frequency signal by a Current to Frequency Con­verter. This frequency signal is then transmitted across an opto­isolator to the output stage.
The 10-50 mA range option is provided to enable the unit to perform range conversions as well as signal isolation.
Specifications:
Analog Input
Available Ranges: 4-20 mA (10-50 mA optional) Input Type: Two Wire, Loop Powered Equivalent Input Impedance: 525 on 4-20 mA range
210 on 10-50 mA range Operational Range: 3.5-33 mA Over Current Protection: 2.5 times rated span Reverse Polarity Protection Isolation Voltage: 500 V Input Loop Indicator: LED illuminates when loop is pow-
ered by proper polarity
Pulse Output Option
Output Type: Open Collector Transistor Low Cutoff: 1% of full scale Range: 0 to 10,000 Hz Duty Cycle: 50/50 Duty Cycle (nominal) Maximum Off Voltage: 30 VDC Minimum On Current: 10 mA Maximum On Voltage: 1 VDC Temperature Effect: Less than 200 ppm/degree C Reverse Polarity Protection
Mounting Styles
DIN Rail Mount: Plastic enclosure with a snap fastener for
fitting to DIN 46 277 and DIN EN 50 022 assembly rails.
NEMA 4: 4.92" x 4.92" NEMA 4 Enclosure for wall
mounting.
Explosion Proof: Aluminum enclosure for:
Class I, Division 1, Groups B, C & D Class II, Division I, Groups E, F & G.
Listing: CE Compliant
Kessler-Ellis Products • 800-631-2165 F-15 • Flow Instruments • Page 11
Dimensions
Flow Instruments
SIGNAL CONDITIONERS
DIN Rail Mount
Simplified Block Diagram
+
1
4-20mA Input Loop
2
3.88 (98.5)
I/F
Span
Zero
+ 24 VDC
7
Open Collector
8
9
Common
.89
(22.5)
Mounting holes molded directly under cover screws. Max. screw head .29" (Typ. 4 places)
4.21
(107)
TOP VIEW
PANEL INSTALLED
1.40 (35.5)
2.95 (75)
NEMA4X
To access terminals, remove
4.21
(107)
4.92
(125)
cover and 4 panel screws.
4.92
(125)
.43
(11)
Explosion Proof Enclosure
3/4” NPT (2) HLS. (feed thru hubs)
.18 (5)
SIDE VIEW
Optional holes or hub fitting
2.95 (75)
1.93 (49)
Typical Wiring Hookup
+
4-20mA Output
4-20 mA Output Device
SC-IF
1 2
+24 V
7
Open Collector Output
8
Common
9
24 VDC Out Pulse Input Common
Pulse Input Device
4.9 - 5.25
(124 - 133)
Ordering Information
5.9 - 7.7
(150 - 196)
4.75 -5
(121 - 127)
Optional 3rd Conduit Entry
All Dimension in inches (mm)
Page 12 • Flow Instruments • F-15 Kessler-Ellis Products • 800-631-2165
Example SC-IF D ET Series
IF= Current to Frequency
Mounting:
B= Nema 4X C= Explosion Proof D= DIN Rail
Options:
ET= Extended Temp: -4° to 185°F (-20° to 85° C) T = Third 3/4" conduit entry for Explosion Proof Housing H2 = 0.875" Hole for NEMA4 mounting style HF2 = 0.5" Female NPT Hub fitting H3 = 1.125" Hole for NEMA4 mounting style HF3 = 0.75" Female NPT Hub fitting
Accessories: (add to end of part number)
DR-4= 4" DIN Rail
Loading...