SC-FI Series
Features:
• Magnetic Pickup or Contact Closure Input
• Optically Isolated Input
• 10 kHz Maximum Input Frequency
• Standard, 2-Wire, 4-20 mA Output
• Two Year Warranty
• Loop Powered
• Various Mounting Styles
• LED Indicator
Frequency to Current
Signal Conditioner
SIGNAL CONDITIONERS
Flow Instruments
Description:
The SC-FI is a two wire frequency to analog converter that
converts a pulse rate input into a 4-20 mA output signal proportional to frequency or rate.
The input pulse rate is amplified and filtered by the input signal
conditioning circuitry. Two forms of input signal conditioning are
provided, one for magnetic pickups or contact closure inputs and
the other is an isolated pulse input (depending on order code).
The amplified frequency signal is then converted to an analog
signal using a precision frequency to analog converter.
The output stage derives it’s power from the output current loop.
The output stage converts the analog input signal into the desired output range. Multi-turn potentiometers provide for the necessary trimming of span and zero.
Specifications:
Operating Temperature
32° F (0°C) to 158°F (70°C)
High Level Pulse Input
Type: Opto-Isolated
Input Impedance: 3.3 kΩ
Logic 1: 4-30 VDC
Logic 0: 0-1 VDC
Frequency Range: 0-10 kHz
Fault Protection: Reverse Polarity Protection
Over Voltage Protection
Isolation Voltage: 500 V
Fast Transient Immunity: 500 V
Maximum Rise Time: No Limit
Maximum Fall Time: No Limit
Magnetic Pickup Input
Differential Input
Input Impedance: 10 kΩ
Frequency Response: 0-3500 Hz
Trigger Sensitivity: 30 mV p-p
Over Voltage Protection: ± 30 VDC
Contact Closure Input
Sensor Compatibility- Requires an isolated, contact closure
Maximum Contact Voltage- 5 V
Maximum Contact Current- 0.12 mA
Nominal Pullup Resistance - 47 Kohm to 5 Vdc
Frequency Range - 0-100 Hz
Frequency to Current Conversion
Range Selection: DIP Switch Selectable
Available Ranges:
Standard
150 Hz, 300 Hz, 600 Hz, 1200 Hz,
2500 Hz, 5000 Hz, 10,000 Hz
Factory Default: 1000 Hz
Contact Closure Option
30 Hz, 60 Hz, 120 Hz, 240 Hz,
480 Hz, 960 Hz, 1920 Hz
Factory Default: 100 Hz
Analog Output
Accuracy: ± 0.1% Span (@ 20° C)
Output Type: Two Wire, Loop Powered
Range: 4-20 mA
Compliance Voltage: 10 to 40 VDC
Loop Burden: < 10 VDC
Trim Controls: Zero & Span, non-interacting
Span (20 mA) Trim Range: 50% to 100% of full scale
Linearity: < ±0.1% Span
Output Voltage Effect: < ± 0.002% Span/Volt
Temperature Effect: < 200 PPM/C°
Reverse Polarity Protected
Noise Content: < 0.2% Span
Response Time: 0.1 second (1 sec. jumper selectable)
Overcurrent Limiting: 35 mA
Output Loop Indicator: LED illuminates when output loop
is powered by proper polarity and
blinks proportionally to the input
frequency.
Mounting Styles
DIN Rail Mount: Plastic enclosure with a snap fastener for
fitting to DIN 46 277 and DIN EN 50 022
assembly rails.
NEMA 4X: 4.92" x 4.92" NEMA 4X Enclosure for wall
mounting.
Explosion Proof: Aluminum enclosure for:
Class I, Division 1, Groups B, C & D
Class II, Division I, Groups E, F & G.
Listing: CE Compliant
Kessler-Ellis Products • 800-631-2165 F-15 • Flow Instruments • Page 7
Dimensions
Flow Instruments
SIGNAL CONDITIONERS
.89
(22.5)
Mounting holes molded
directly under cover screws.
Max. screw head .29"
4.21
(107)
(Typ. 4 places)
4.21
(107)
4.92
(125)
TOP VIEW
PANEL INSTALLED
Explosion Proof Enclosure
4.9 - 5.25
(124 - 133)
DIN Rail Mount
1.40 (35.5)
2.95 (75)
NEMA4X
To access terminals, remove
cover and 4 panel screws.
4.92
(125)
.43
(11)
3/4” NPT (2) HLS.
(feed thru hubs)
.18 (5)
SIDE VIEW
Optional holes
or hub fitting
3.88 (98.5)
2.95
(75)
1.93
(49)
Terminal Designations
Standard
Termination
1• Magnetic pickup
2• Magnetic pickup
3• Shield (common)
4• Opto-isolator In +
5• Opto-isolator In –
6• Shield (common)
7• Output +
8• Output –
9• Do Not Use
Simplified Block Diagram
mV
Input
3-30V
Input
+
–
10kΩ
10kΩ
3.3kΩ
Typical Application
Magnetic Pickup Input
Raw Signal
Flowmeter
with Magnetic Pickup
Typical Application
Contact Closure Input
Flowmeter
with Contact Closure
SCFI-X-L (low count speed)
Termination
1• Do Not Use
2• Contact Input
3• Shield (common)
4• Opto-isolator In +
5• Opto-isolator In –
6• Shield (common)
7• Output +
8• Output –
9• Do Not Use
Span
F/V
Zero
V ref
1
2
SCFI
Mag Pickup Input
2
3
SCFI-X-L
with Slow Speed
Input Option
V/I
Loop Powered
4-20mA Output
7
8
R
L
7
8
R
L
+
–
+
–
+
–
5.9 - 7.7
(150 - 196)
4.75 -5
(121 - 127)
Example SC-FI D ET
Series
FI= Frequency to Current
Ordering Information
Mounting:
B= Nema 4X
C= Explosion Proof
D= DIN Rail
Options:
ET= Extended Temp: -4° to 185°F (-20° to 85° C)
L = Low Count Speed for Contact Closure Inputs
T = Third 3/4" conduit entry for Explosion Proof Housing
H2 = 0.875" Hole for NEMA4 mounting style
HF2 = 0.5" Female NPT Hub fitting
Optional 3rd
Conduit Entry
All Dimension in inches (mm)
H3 = 1.125" Hole for NEMA4 mounting style
HF3 = 0.75" Female NPT Hub fitting
Accessories: (add to end of part number)
DR-4= 4" DIN Rail
Page 8 • Flow Instruments • F-15 Kessler-Ellis Products • 800-631-2165