KEP AMP-1-N Data sheet

AMP-1-N
Features
• NAMUR Compatible Sensitivity.
•100 mA Current Sinking Output.
•11 to 26 VDC Power Supply Range.
• Easy Mount Metal Housing.
Preamplifier & Signal Conditioners For NAMUR Sensors
Description
The KEP AMP-1-N powers and conditions the low level signals from NAMUR pickups, sensing gear teeth movement or flow, and provides a high level pulse output suitable to drive any KEP ratemeter, counter or controller.
Application
AMP-1-N
Specifications Environmental
Operating temperature:32° to 140° F (0° to 60° C) Storage temperature: -40° to +85° C Humidity: 0 - 95% non-condensing
Power Input
Power requirement: 11-26VDC; 30mA maximum
Sensor Supply: 8VDC ± 1 VDC
Input Characteristics
Input impedance: 1000 ohm nominal Input frequency : 0 - 10kHz
Input current: High: > 3mA
Low: < 1 mA
Output Characteristics
Output Type: Open collector with internal
2700 ohm pull-up resistor to supply voltage.
Max. sink current: 100mA sink to 1V or less
Turbine Meter with
NAMUR Pickup
8 1 4 2 3 5
RST
A B C D
ENTER LOCK PRE A PRE B VIEW PRGM
Totalizer
E
Approvals:
CE approved; Light Industrial Fast transient: 500V (capacitive clamp) EMI: No effects at 3V/m ESD: 8kV (case grounded)
Kessler-Ellis Products Co. 10 Industrial Way East, Eatontown, NJ 07724
Toll Free: 800-631-2165 • Phone: 732-935-1320 • Fax: 732-935-9344
99987 02/08/05
Installation
The AMP-1-N is mounted in a rugged 2" x 3" metal housing with screw terminals for easy installation. When installing the AMP-1-N the metal case housing must be grounded. All input and output connections should be run with shielded cable. Connect cable shield to shield terminal of AMP-1-N (TBI pin 1). The signal line from the NAMUR pickup to the AMP-1-N must be less than 100 ft. in length, shielded and separated from relays, solenoids or other sources of electrical noise.
Sample Hookup :
Dimensions:
.67
(17)
.15
(3.8)
1.4
(35.6)
3.00
(76.2)
2.2
(55.9)
NAMUR PICKUP
1 NC 2 INPUT 3 8 VDC
GEAR OR
TURBINE
WARRANTY
This product is warranted against defects in materials and workmanship for a period of two (2) years from the date of shipment to Buyer.
The Warranty is limited to repair or replace­ment of the defective unit at the option of the manufacturer. This warranty is void if the prod­uct has been altered, misused, dismantled, or otherwise abused.
TB1
AMP -1-N: Standard unit
TB2
3 OUTPUT 2 GND 1 11-26 VDC @ 30 mA
SIMPLY ORDER:
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WAR­RANTIES OF MERCHANTABILITY AND FIT­NESS FOR A PARTICULAR PURPOSE.
KESSLER-ELLIS PRODUCTS
10 Industrial Way East Eatontown, NJ 07724 800-631-2165 732-935-1320 Fax 732-935-9344 http://www.kep.com