KEP 529K, 530K Data sheet

520K-529K
520K-530K
New Family: Your choice for your application!
Features
• LED display with very high luminosity
• 0.315" (8mm) digit height
•6 digit display
• DIN housing, 1.88"x.944" (48x24mm)
• Easy 2 button programming
• Connection with screw terminal
• IP65 NEMA 4X (front)
• Input pulse-shape variable (Schmitt Trigger characteristics)
Pulse Counters, Position Displays, Rate Meters, Time Meters & Combinations
COUNTERS
520K
Simple Display Counter
• Display range
0..999999 with leading zero blanking
• Count frequency up to 10kHz (can be damped to 30Hz in setup)
• SET-key resets the counter to zero (can be disabled in setup)
•1 count input
•1 reset input
Order #: 520K.2
521K
Totalizer and Postion
indicator
• Display range
-199999..0..999999 with leading zero blanking
• Count frequency up to 10kHz (can be damped to 30Hz in setup)
• SET-key resets the counter to zero (or selected preset number)
•2 count inputs
•1 reset input
• Multiplying factor (0.00001...99.9999)
• Option: optocoupler output if count value ≤ 0
• Counting with direction input, differential counting, counting with phase discriminator (also with pulse doubling)
Order #: 521K.1 w/optocoupler 521K.2 w/out optocoupler
522K
Frequency meter and
Tachometer
• Display range 0..999999 with leading zero blanking
• Indicates rate per sec or min (1/Tau) to 0.1% accuracy
• Input frequency up to 10kHz (can be damped to 30Hz in setup)
•1 count input
• Operating principle: period duration measurement (average value at higher frequencies)
• Option: optocoupler output if frequency f=0 (e.g. no operation indicator)
• Multiplying factor (0.00001...99.9999)
Order #: 522K.1w/optocoupler 522K.2 w/out optocoupler
NOTE: E200 Outdoor Enclosure and N7 Explosion Proof Housing available
for all Models (see accessories section)
523K
Time meter
• Display range 0..999999 with leading zero blanking to 0.03% accuracy
• Lowest digit's decimal point flashes when timing
• Timing in s, min, h or h.min.s (programmable) Timing resolution x1, .1, .01, .001, fixed by selected decimal point
• SET-key resets the counter to zero
• Gate, start and stop via 2 inputs (progammable)
•1 reset input
• Operation mode: Precise timing from hours to 1/1000 sec
• Option: optocoupler output (e.g. Timing indicator, 0.5 sec On/ Off)
Order #: 523K.1 w/optocoupler 523K.2 w/out optocoupler
524K
Multipurpose device
• 521K-523K in just one device
• Operation mode can be programmed
Order #: 524K.1 w/optocoupler 524K.2 w/out optocoupler
Kessler-Ellis Products • 800-631-2165 II-15 • Industrial Instruments • Page 35
525K
Adding Counter and
Tachometer
526K
2 Display Counters
527K
Display Counter and
Time meter
528K
2 Time meters
529K/530K
Analog Displays
• Display range 0..999999 with leading zero blanking
COUNTERS
• Count frequency up to 10kHz
• Indicates rate / sec or min (1/Tau)
• SET-key resets the counter to zero (can be disabled in the setup)
• Key to switch rate / total display
•1 count input
•1 reset input
• Seperate multiplying factors for totalizer & ratemeter (0.00001...99.9999)
• Operating mode: Rate meter: 1/Tau (average value at higher frequencies)
Order #: 525K.2
• Display range 0..999999 with leading zero blanking
• Overflow indicated by the leading zeros
• Count frequency up to 10kHz
• SET-key resets the counter to zero (can be disabled in setup for each counter seperately)
• Push-button for switching between counter 1 and counter 2
•1 count input
•1 reset input (program­mable for each counter seperately in setup)
• One multiplying factor (0.00001...99.9999)
Order #: 526K.2
• Display range 0..999999 with leading zero blanking (Overflow shows leading zeros)
• Lowest digit's decimal flashes when timing
• Adding counter: Decimal point only optical function
• Hour meter: Timing in s, min, h or h.min.s (programmable) Decimal point fixes the resolution
• SET-key resets the counter to zero (can be seperately disabled in the setup for each channel )
• Push-button switches adding counter / time meter
• Count frequency up to 10kHz
•1 count input
• Gate, start and stop via 1 input (progammable)
•1 reset input (can be disabled in setup)
• Multiplying factor (0.00001...99.9999)
Order #: 527K.2
• Display range 0..999999 with leading zero blanking
• Active timing will be indicated by flashing the lowest digit's decimal point (one control)
• Timing in s, min, h or h.min.s (programmable) Decimal point fixes the resolution (ex: 1, 0.1, 0.01, 0.001)
• SET-key resets the counter to zero (can be disabled in the setup)
• Push-button for switching between time meter 1 and 2
• Gate, start and stop via 2 inputs (progammable)
•1 reset input (program­mable for each timer seperately in setup)
Order #: 528K.2
• Display range
-19999..0..99999 with leading zero blanking
• Resolution 14 bit
•5 digit display 6 digit total display (530K)
•4 different resolutions (0..20mA; 4..20mA;
0..10V or 2..10V)
• Scaling factor for displayed value
• Automatic storage of maximum and minimum value (can be disabled in setup)
• Input to activate storing of displayed value
Order #: 529K.2 = Rate Display
Only
530K.2 = Rate and Total
Display
NOTE: E200 Outdoor Enclosure and N7 Explosion
Proof Housing available for all Models (see accessories section)
Electrical characteristics:
• Supply Voltage: 10 to 30 VDC
• Data retention: EEPROM (1 million cycles or 10 years)
• Noise immunity acc. to EN 50081-2; EN55011 class B; EN 50082-2
• Ambient temperature: 14°F to 122°F (-10°C to +50°C)
• Input sensitivity: Low: 0 to 1 VDC High: 4 to 30 VDC
• Input resistance: 10 k ohm
• Polarity of inputs: programmable for all inputs in common
• Optocoupler: Max 30VDC, 10 mA, 1V drop @ 10 mA
Page 36 • Industrial Instruments • II-15 Kessler-Ellis Products • 800-631-2165