SPECIFICATIONS ................................... BACK COVER
TK-272G
GENERAL / SYSTEM SET-UP
INTRODUCTION
SCOPE OF THIS MANUAL
This manual is intended for use by experienced technicians
familiar with similar types of commercial grade communications
equipment. It contains all required service information for the
equipment and is current as of the publication date. Changes
which may occur after publication are covered by either Service
Bulletins or Manual Revisions. These are issued as required.
ORDERING REPLACEMENT PARTS
When ordering replacement parts or equipment information,
the full part identification number should be included. This
applies to all parts, components, kits, or chassis. If the part
number is not known, include the chassis or kit number of which
it is a part, and a sufficient description of the required
component for proper identification.
Unit
Model &
destination
TK-272G
K2X57-5870-13
TX-RX UnitDisplay UnitFrequency rangeRemarks
KX57-5870-11150~174MHzIF1 : 49.95MHz
X54-3250-10
136~150MHzLOC : 50.4MHz
PERSONNEL SAFETY
The following precautions are recommended for personnel
safety:
●
DO NOT transmit until all RF connectors are verified secure
and any open connectors are properly terminated.
●
SHUT OFF and DO NOT operate this equipment near
electrical blasting caps or in an explosive atmosphere.
●
This equipment should be serviced by a qualified technician
only.
SERVICE
This radio is designed for easy servicing. Refer to the
schematic diagrams, printed circuit board views, and alignment
procedures contained within.
SYSTEM SET-UP
Merchandise received
License and frequency allocated by FCC
Choose the type of transceiver
Transceiver programming
Are you using the optional antenna?
Are you using the speaker microphone?
NO
NO
Delivery
Frequency range (MHz) RF powerType
TX/RX 150~174
TX/RX 136~150
A personal computer (IBM PC or compatible), programming
interface (KPG-22), and programming software (KPG-56D)
are required for programming.
(The frequency, TX power HI/LOW, and signalling data are programmed
for the transceiver.)
YES
YES
KRA-14
Helical antenna
(Option)
KMC-17 or KMC-21
Speaker microphone
(Option)
5.0W
5.0W
TK-272G K
TK-272G K2
2
OPERATING FEATURES
TK-272G
1. Operation Features
Antenna
ee
ww
e
w
ee
qq
ww
q
qq
Microphone
Speaker
rr
r
rr
ii
i
ii
tt
t
tt
yy
y
yy
uu
u
uu
The transceiver is shown with the optional KNB-14 battery pack.
qq
q Rotary encoder
qq
Your dealer can program the encoder as either Group
Up/Down (only when the trunking board is installed)
or Channel Up/Down (default setting). Rotate to
select a group or channel. Also rotate to adjust the
squelch in Squelch Adjustment mode.
ww
w LED indicator
ww
Lights red while transmitting. Lights green while
receiving. Flashes orange while receiving a Code
Squelch or Selective Call code, or a 2-Tone or DTMF
signal that matches the one set up in your transceiver .
Flashes red when the battery power is low while
transmitting.
ee
e Power switch/ Volume control
ee
Turn clockwise to switch ON the transceiver. Rotate
to adjust the volume. To switch OFF the transceiver,
turn counterclockwise fully.
rr
r PTT (Push-to-Talk) switch
rr
Press this switch, then speak into the microphone to
call a station.
tt
t Side 1 key
tt
This is a PF (Programmable Function) key. Press it
to activate its auxiliary function.
yy
y Side 2 key
yy
This is a PF (Programmable Function) key. Press it
to activate its auxiliary function.
uu
u
uu
22
33
, •,
2,
3 keys
22
33
°
These are PF (Programmable Function) keys.
Press each key to activate its auxiliary function.
ii
i SP/MIC jacks
ii
Connect an optional speaker/ microphone here.
oo
o
oo
oo
o Display
oo
Note: The PF keys are programmed with default functions:
•
Side 1 key: Lamp
•
Side 2 key: Monitor A
•
key:Scan
°
•
key:Scan Del/Add
•
22
•
2
key:Talk Around
22
33
•
3
key:RF Power Lo
33
Programmable Auxiliary Functions
Side 1, Side 2, °, •,
22
2, and
22
33
3 can be programmed
33
with the auxiliary functions listed below.
• Channel Down
• Channel Up
• Display Character
• Group Down
• Group Up
• Home Channel
• Key Lock
• Lamp
• Monitor A (Monitor Unmute–Momentary)
• Monitor B (Monitor Unmute–Toggle)
• Monitor C (Carrier Squelch–Momentary)
• Monitor D (Carrier Squelch–Toggle)
• None
• Operator Sel Tone
• Redial
• RF Power Lo
• Scan
• Scan Del/Add
• Talk-Around
• 2-Tone Encode
• Trunking Group Code Select
1
Available for K market models only.
2
Available only when using Trunking function.
2
2
1
2
2. Programmable keys
The functions the FPU programs to the function keys are
described in the following sections.
1) Channel up/down
When the key is pressed each time, the channel number to
be selected is incremented/decremented and repeats if held
for one second or longer.
2) Display character
This key switches the LCD display between the group/
channel number and group/channel name.
3) Group up/down
When the key is pressed each time, the group number to
be selected is incremented/decremented and repeats if held
for one second or longer.
3
TK-272G
OPERATING FEATURES
4) Home Channel
Press this key once, the channel switches to the preprogrammed home channel.
5) Key lock
When the KEY LOCK switch is held down for one second
or more, keys other than [PTT], [Side1], [Side2], [VOL],
[POWER], and KEY LOCK are locked.
When 12/16 KEY LOCK is set with the FPU, the DTMF
key is locked and when front-panel KEY LOCK is set, the
DTMF key and the [PF] key are locked.
6) Lamp
This key illuminates the LCD and keys on the front panel.
When the key is pressed, the LED lamp goes on.
When it is released, the lamp goes off after about five
seconds. If any key is pressed while the LED lamp is on,
the lamp is kept on for five seconds.
7) Monitor
Used to release signalling or squelch when operating in
conventional mode. It is also used to reset option signalling.
8) Operator Selectable Tone
This key switches the pre-set decode QT/DQT and encode
QT/DQT to OST (Operator Selectable Tone) tone pair.
Press this key, the transceiver enters OST mode. In this
mode, the display shows "OFF" and the operator can select
one of the OST tone pair using the tuning control. The display
shows "TONE ∗∗" and tone pair No. ∗∗ is selected.
Press OST key again, the transceiver exits from OST mode,
and returns to the group/channel mode.
16 tone pairs for OST can be programmed by KPG-56D.
OST is useful to access the repeater with same radio
frequency and different tone (QT/DQT).
9) 2-Tone Encode Select
1 Press the key programmed as 2-tone Encode Select.
• A pre-programmed 2-tone code name appears on the
display.
2 Press the key programmed as Rotary encoder to select
you desired 2-tone code name.
3 Press PTT switch and 2-Tone Encode Select key to transmit
and release them to receive.
10) RF power low
Used to temporarily switch transmission output to low power.
Turning the function on enables:
Hi→Low, Low→Low
Key states are backed up, except in the PC mode when
they are reset.
The "Add" channel is contained in the scan sequence, the
"Delete" channel is not contained. In the scan mode, this key
switches the channel between delete or add, temporarily.
13) Talk Around
Press this key, the transceiver uses the receive frequency
and tone for transmission.
The operator can call the other party directly (without
repeater). Press this key again, the talk around function
goes off.
14) None
An error operation beep sounds, and no action will occur.
Use this function when the transceiver is required to be
operated more simply.
3. Display
IconDescription
Appears while using Smar Trunk.
Appears when the selected channel is
busy.
Appears when QT, DQT, DTMF, or 2Tone decoding is deactivated (by
pressing the Monitor key).
Appears when you receive a Code
Squelch, Selective Call, 2-Tone, or
DTMF Signalling call. Also appears
when you transmit using Code Squelch
or Selective Call.
Appears while scanning.
Appears when using low power on the
selected channel.
Appears when the selected channel is
included in the scanning sequence.
Displays the selected channel, the
squelch level, DTMF digits (when
entering digits, confirming digits, or
making a call), and messages received
via Selective Call.
11) Scan
Pressing this key starts scanning. Pressing this key again
stops scanning.
12) Scan Del/Add
This key switches the currently displayed channel between
"Delete" and "Add".
4
4. Scan Operating
1) Scan types
●
Single Group Scan
You can scan all valid (ADD) channels in the displayed group
that can be selected with the group selector.
OPERATING FEATURES
TK-272G
●
Multiple Group Scan
You can scan all valid (ADD) channels in all valid (ADD)
groups.
2) Scan Start Condition
One or more non-priority channels must be added to all
channels that can be scanned. The transceiver must be in
normal receive mode (PTT off).
When you activate the key programmed to the scan function,
scan starts. The scan icon ("SCN") lights and "SCAN" is
indicated on display.
3) Scan Stop Condition
The scan stops temporarily if the following conditions are
satisfied.
1 The receiving signal matches the signalling code in your
radio that is set by the programming software (KPG-56D).
2 When the Monitor key is depressed.
4) Scan Channel Types
1 Priority channel is the most important channel for scan,
and always detects a signal during scan and when the scan
stops temporarily.
2 Non-priority channels detect a signal during scan. For the
channels that can be selected with the group or channel
selector when the scan does not occur, the "A" icon lights.
5) Priority Channel Setting
A priority channel can be set as follows with the programming
software (KPG-56D).
1 Specify a priority channel as a fixed priority channel.
2 Make a selected channel a priority channel.
Specify the initial channel before the operator changes it.
6) Scan Type According to the Priority Channel
1 When no priority channel is set : Only the non-priority
channels are scanned.
If a non-priority channel stops temporarily, it stops until
there is no signal on the channel.
2 When priority channel is set : Either priority channel is
scanned.
If a non-priority channel stops temporarily, a priority channel
signal is detected at certain intervals.
If a priority channel stops temporarily, it stops until there is
no signal on the priority channel.
7) Revert Channel
The revert channel is used to transmit during scanning and
set by the programming software (KPG-56D).
1 Priority
The transceiver reverts to the priority channel.
2 Priority with talkback
The transceiver reverts to the priority channel.
If you press PTT during a resume timer (dropout delay time,
TX dwell time) or calling, you can transmit on the current
channel to answer to the call however revert channel is set
to priority channel.
After resume time, scan re-starts and the transmission
channel returns to the priority channel.
3 Selected channel
The transceiver reverts to the channel before scanning or
the channel that you changed during scan.
4 Last called channel
The transceiver reverts to the last called channel during
scan.
5 Last used channel
The transceiver reverts to the last used (transmitted)
channel during scan. "Last used" revert channel includes
talkback function.
6 Selected with talkback
The transceiver reverts to the channel before scanning or
the channel that you changed during scan.
8) Scan End
When you reactivate the key programmed to the scan
function during scan mode, scan ends.
The scan icon ("SCN") and "SCAN" or revert channel
(programmable) display goes off.
9) Temporarily Delete/Add
It is possible to delete or add a channel temporarily during
scan. When scan stops on an unnecessary channel, for
example by interference of the other party, press the delete/
add key, then that channel is deleted temporarily and scan will
re-start immediately.
When you would like to add a deleted channel temporarily
to the scan sequence, select the desired (deleted) channel
during scan, and press the delete/add key before scan re-starts.
That channel is added temporarily to the scan sequence.
The temporarily deleted or added channels are returned to
their pre-set delete/add conditions when the transceiver exits
from scan mode.
5. Details of Features
1) Time-out timer
The time-out timer can be programmed in 15 seconds
increments from 15 seconds to 300. If the transmitter is keyed
continuously for longer than the programmed time, the
transmitter is disabled and a warning tone sounds while the
PTT button is held down. The alert tone stops when the PTT
button is released.
2) PTT ID
PTT ID provides a DTMF ANI to be sent with the PTT button
every time it is used (Begin of TX ID at beginning of
transmission, End of TX ID at end of transmission, or both).
You can program the PTT ID as one of the followings.
Off, BOT (Begin of TX ID), EOT (End of PTT ID), BOTH.
The contents of ID are programmed for each channel.
5
TK-272G
OPERATING FEATURES
The transceiver is capable of having ID. The format is DTMF.
The timing that the transceiver sends the ID is
programmable.
Begin of TX ID (BOT) : Begin of TX ID is sent at the
beginning of transmission.
End of TX ID (EOT) : End of TX ID is sent at the end of
transmission.
Both : Begin of TX ID is sent at the beginning of transmission
and End of TX ID is sent at the end of transmission.
There is also a "PTT ID" setting for each channel.
3) Battery Warning
This transceiver has a battery warning feature. If low voltage
is detected during transmission, the transceiver warns you by
a flashing red "LED".
When the voltage is detected to be even lower during
transmission, the transceiver stops transmission and warns
you by a flashing red "LED" and a beep.
Please notice "indication" for the battery exchange, charging
time by flashing red LED and beep.
4) "TOT" Pre-Alert
The transceiver has a "TOT" pre-alert timer. This parameter
selects the time at which the transceiver generates a "TOT"
pre-alert tone before the "TOT" is expired.
"TOT" will expire when the selected time passes from the
TOT pre-alert tone.
5) "TOT" Re-Key Time
The transceiver has a "TOT" re-key timer. This timer is the
time you cannot transmit after the "TOT" is exceeded. After
the "TOT" re-key time expires you can transmit again.
6) "TOT" Reset Time
The transceiver has a "TOT" reset timer. This timer is the
minimum wait time allowed during a transmission that will reset
the "TOT" count.
"TOT" reset time causes the "TOT" to continue even after
the PTT is released, unless the "TOT" reset timer has expired.
7) OST (Operator Selectable Tone)
The transceiver is capable of having the "OST" function
and 16 tone pairs (QT/DQT) with a max 10-digit name for each
tone pair.
8) Clear to Transpond
The transceiver waits for an acknowledment signal until the
channel free.
This feature ensures the acknowledment signal is receive
by another party.
9) Battery Save
This is the automatic battery saver during standby mode
operation. The receiver circuit is turned on and off to conserve
the battery life.
6. Option Signalling (DTMF/2 tone)
Built-in DTMF decoder is available for option signalling.
Built-in 2-Tone decoder is available for option signalling.
It is possible to use individual call, group call, DBD (Dead
Beat Disable). Note : DBD is only DTMF
Preset operation is triggered when there is a match with
Option Signaling.
When Option Signaling matches on a Group Channel
where it is set to Yes, the Option Signaling display flashes
and Option Signaling is canceled. Settings after this will cause
"Transpond" or "Alert" to sound.
Setting the Selective Call Alert LED will cause the LED to
start flashing orange.
Mute or Unmute is triggered by the ID/QT/DQT/Carrier
when option signaling matches (when Option Signal is
deactivated by a transmission).
AND/OR
Option Signaling match conditions can be selected with
AND/OR logic.
Alert/TranspondAF Mute Open
AND
Even if set as OR, there is no Alert/Transpond just with
DTMF.
Even if set as OR, AF mute cannot be canceled just by a
match with DTMF.
In conventional channels not set with QT/DQT, signaling is
a match just by receiving the carrier.
Auto Reset
When Option Signaling matches on a Group channel where
it is set to Yes, Option Signaling is canceled when it matches a
group channel set to Yes.
After Option Signaling matches, Option Signaling can
automatically Reset after a specified time.
Dead Beat Disable
When the D.B.D (Dead Beat Disable) code matches, a
preset operation is performed.
When D.B.D matches on all group channels regardless of
whether Option Signaling = Yes/No, then TX Inhibit or TX RX
Inhibit is activated by the settings performed afterwards. D.B.D
is canceled when the D.B.D. code + "#" is received.
Transpond is always activated when the D.B.D code
matches. Alert is not output. An Option Signaling match is not
displayed.
Triggers at match with QT/ Triggers at match with QT/
DQT/ID+DTMF(2tone);Opt
ORTriggers at match with
DTMF(2tone);Opt
DQT/ID+DTMF(2tone);
Triggers only for match with
QT/DQT/ID;Signaling
Opt
6
OPERATING FEATURES / REALIGNMENT
TK-272G
7. Audible user feedback tones
The transceiver outputs various combinations of tones to
notify the user of the transceiver operating state. The main
tones are listed below
The high tone is 1477Hz, the mid tone is 941Hz, and the
low tone is 770Hz.
• Power on tone
This tone is output when the transceiver is turned on. (The
high tone is output for 500ms.)
• Alert tone
This tone is output when the transceiver is in TX inhibition
for TOT, battery warning and PLL unlocked. It is output until
the PTT button is released. (The 697Hz tone is output.)
• Busy Tone
This informs the user of a busy channel lock out
• Group Call Tone
The group call tone informs the user of a group call in DTMF/
2 Tone Option Signaling. This tone repeats 7 times.
770Hz770Hz
30ms30ms30ms
• Individual Tone
Individual tone is issued on receiving selective call by DTMF/
2 Tone Option Signaling.
2000Hz2000Hz2000Hz
100ms100ms100ms100ms100ms
• Pre Alert tone
Informs the user when nearing transmit inhibit (transmit
cutoff) time due to TOT.
The Pre Alert Tone is issued from the time set for TOT Pre
Alert until the TOT triggers.
1633Hz1633Hz1633Hz
50ms50ms50ms50ms50ms
REALIGNMENT
1. Modes
User mode
Panel test mode
PC mode
Firmware
programming mode
Clone mode
Self programming
mode
ModeFunction
User modeFor normal use.
Panel test modeUsed by the dealer to check the
Panel tuning modeUsed by the dealer to tune the radio.
PC modeUsed for communication between the
Data programmingUsed to read and write frequency data
mode
PC test modeUsed to check the radio using the PC.
Firmware program-Used when changing the main
ming modeprogram of the flash memory.
Clone modeUsed to transfer programming data
Self programmingFrequency, signalling and features.
mode
Panel tuning mode
Data programming
mode
PC test mode
Checksum
fundamental characteristics.
radio and PC (IBM compatible).
and other features to and from the radio.
This feature is included in the FPU.
See panel tuning.
from one radio to another.
PC tuning mode
2. How to Enter Each Mode
ModeOperation
User modePower ON
Panel test mode
PC modeReceived commands from PC
Panel tuning mode[Panel test mode]+[°]
Firmware programming mode
Clone mode[Side1]+[3]+Power ON
Self programming mode[Side1]+[
[2]+Power ON (Two seconds)
[Side1]+[Side2]+Power ON
(Two seconds)
(Two seconds)
]+Power ON
(Two seconds)
•
3. For the panel Test Mode
For the setting method, refer to ADJUSTMENT.
3-1. For the panel Tuning Mode
For the setting method, refer to ADJUSTMENT.
4. Checksum
Executing this function, "TUNING" appears on the display
of TK-272G while calculating the checksum .
When the calculation is completed, the display returns to
normal and PC displays the checksum of the radio.
7
TK-272G
REALIGNMENT
5. PC Mode
5-1. Preface
The TK-272G transceiver is programmed using a personal
computer, a programming interface (KPG-22) and
programming software (KPG-56D).
The programming software can be used with an IBM PC
or compatible. Figure 1 shows the setup of an IBM PC for
programming.
5-2. Connection procedure
1. Connect the TK-272G to the personal computer with the
interface cable.
2. When the POWER is switched on, user mode can be
entered immediately. When the PC sends a command,
the radio enters PC mode.
When data is transmitted from transceiver, the red LED blinks.
When data is received by the transceiver, the green LED blinks.
Notes:
•The data stored in the personal computer must match the
model type when it is written into the flash memory.
•Change the TK-272G to PC mode, then attach the interface
cable.
IBM-PC
5-3. KPG-22 description
(PC programming interface cable: Option)
The KPG-22 is required to interface the TK-272G to the
computer. It has a circuit in its D-subconnector (25-pin) case
that converts the RS-232C logic level to the TTL level.
The KPG-22 connects the SP/MIC connector of the TK272G to the computers RS-232C serial port.
5-4. Programming software description
The KPG-56D programming disk is supplied in 3-1/2” disk
format. The software on this disk allows a user to program the TK272G radios via a programming interface cable (KPG-22).
5-5. Programming with IBM PC
If data is transferred to the transceiver from an IBM PC
with the KPG-56D, the destination data (basic radio
information) for each set can be modified. Normally, it is not
necessary to modify the destination data because their values
are determined automatically when the frequency range
(frequency type) is set.
The values should be modified only if necessary. Data can
be programmed into the flash memory in RS-232C format via
the universal connector.
KPG-56D installation manual part No. : B62-1153-XX
KPG-56D
RF Power meter
or SSG
6. Firmware Programming Mode
6-1. Preface
Flash memory is mounted on the TK-272G. This allows the
TK-272G to be upgraded when new features are released in
the future. (For details on how to obtain the firmware, contact
Customer Service.)
6-2. Connection procedure
Connect the TK-272G to the personal computer (IBM PC
or compatible) with the interface cable (KPG-22). (Connection
is the same as in the PC Mode.)
6-3. Programming
1. Start up the programming software (KPG-56D), select
"firmware program" in the "Program" item, and press the
Return key on your personal computer. This starts up the
firmware programmer.
2. The top screen is displayed. Press any key to advance to
the next screen.
3. Set the communications speed (normally, 57600 bps) and
communications port in the Setup item.
8
KPG-22
+
SP
}
-
+
MIC
}
-
Tuning cable
(E30-3216-05)
Gray
Gray/Black
1.5D-XV Lead wire
1.5D-XV Shield wire
Fig. 1
4. Set the firmware to be updated by File select (=F1).
5. Hold down the [Side1] and [Side2] switches on the TK-272G,
and press the power switch.
When the [Side1] and [Side2] switches are held down for
two seconds, "PROG576" appears on the display and
the LED lights orange. When "PROG576" is displayed,
release the switches .
6. Check the connection between the TK-272G and the
personal computer, and make sure the TK-272G is in
Program mode.
7. Press F10 on the personal computer. A window opens on
the display to indicate the writing progress. When the TK272G begins to receive data, the LED lights green.
8. When data is received successfully, a checksum appears
on the display.
9. If you want to continue programming other TK-272Gs,
repeat steps 5 to 8.
REALIGNMENT
TK-272G
Notes:
●
To start the Firmware Programmer from KPG-56D, the
Fpro path must be set up by the KPG-56D Setup.
●
This mode cannot be entered if the Firmware Programming
mode is set to Disable in the Programming software (KPG56D).
●
When programming the firmware, it is recommend to copy
the data from the floppy disk to your hard disk before you
update the radio firmware.
Directly copying from the floppy disk to the radio may not
work because the access speed is too slow.
6-4. Function
1. If you press the [Side2] switch while "PROGXXX" is
displayed, the checksum is displayed. If you press the
[Side2] switch again (while the checksum is displayed),
"PROGXXX" is redisplayed.
2. A transmission speed can be selected by pressing the [Side1]
switch while "PROGXXX" is displayed.
19200 bps: The LED flashes green and red alternately.
38400 bps: The LED flashes orange.
57600 bps: The LED lights orange.
Note:
Normally, write in the high-speed mode.
7. Clone Mode
Programming data can be transferred from one radio to
another by connecting them via their SP/MIC connectors. The
operation is as follows (the transmit radio is the master and
the receive radio is the slave).
Note: You can clone the programmed data between the
transceiver frequency version must be same.
Cloning cable parts No.
E30-3410-05 (TK-272G → TK-272G)
PTT/RXD
φ
3.5
GND
REMOTE/TXD
φ
2.5
Cloning cable
φ
Fig. 2
8. Self Programming Mode
Write mode for frequency data and signalling etc. Mainly
used by the person maintaining the user equipment.
8.1 Self programming mode setting
Remove D17 from the TX-RX unit (Figure 3). Hold down
the [Side1]+[●] switches and turn the power switch on.
When the self programming mode is entered, [SELF]
appears on the display. The mode changes automatically
to Model Select Mode and "PORTABLE" is displayed in
about one second.
2.5
φ
3.5
1. Turn the master TK-272G power ON with the [Side1]+[3]
keys held down. The TK-272G displays "
2. Power on the slave TK-272G.
3. Connect the cloning cable to the SP/MIC connectors on
the master and slave.
4. Press the [
"
CLONE ". The data of the master is sent to the slave.
While the slave is receiving the data, "-PC-" is displayed.
When cloning of data is completed, the master displays
"END", and the slave automatically operates in the User
mode. The slave can then be operated by the same program
as the master.
5. The other slave can be continuously cloned. When the [
key on the master is pressed while the master displays
"END", and the slave the master displays "
Carry out the operation in steps 2 to 4.
Note: Use the new cloning cable for TK-272G.
You cannot use the old cloning cable for TK-260/270.
] key on the master while the master displays
°
CLONE ".
°
CLONE ".
Note :
This mode (self programming mode) cannot be set when it
has been disabled with the FPU.
Note :
Self programming is disabled if "a Trunking Board is installed
in this Radio" is selected in the FPU.
X57-587X
Compoent Side
]
D17
Fig. 3
9
TK-272G
●
Flow Chart
Radio type
[2]
Self programming mode
[Side2]
Channel set mode
Function set mode
8-2. Channel Setting Mode
This is a mode for making channel settings with the panel
keys without using the FPU.
Pressing [Side2] when "SELF" is displayed, sets Channel
Setting Mode.
Select an item set using [3] then change the selection with
the encoder.
The data displayed using [2] is stored in the memory and
then proceeds to the next item. Pressing [3] proceeds to
the next item without storing it in the memory.
Press [Side2] to set the display to "SELF" and return to reset
(default) status.
All channel data is cleared when pressing [2] key with the
blank RX frequency.
Blank————
NO
YES
No
Yes
High Power
Low Power
Wide
NARROW
DELETE
ADD
No
Yes
No
Yes
No
Yes
OFF
Begin of TX
End of TX
Both
0009999999999999999
Blank
0009999999999999999
Blank————[Side1
DTMF
2TONE
___ID___
12345678
——987Display when a code is input
BCL_NO__
BCL_YES
SHFT_NO_
SHFT_YES
PWR_H___
PWR_L___
WIDE__
NARROW__
SCAN_DEL
SCAN_ADD
P.CH_NO__ Not used when (Scan)
P.CH_YES_
H.CH_NO__
H.CH_YES_
COMP_NO_
COMP_YES
P.ID_OFF
P.ID_1
P.ID_2
P.ID_3
_BOT_ID_
12345678
——987
————
_EOT_ID_
12345678
——987
Default
____
___
Display when an item is selected
Display of the current setting
(If it is 8 or more digits, scroll it.)
(Input it with DTMF key.) *1
[Side1] : Data clear
Default
BCL_YES for K, K2 type
Default
Default
Default
Priority is not Fixed.
Not used when Home Channel is
not set in Key Assignment.
Not valid if Dial ID =Disable and
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
Display of the current setting
(If it is 8 or more digits, scroll it.)
Display when a code is input
(Input it with DTMF key.) *1
[Side1] : Data clear
Not valid if Dial ID =Disable and
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
Display of the current setting
(If it is 8 or more digits, scroll it.)
Display when a code is input
(Input it with DTMF key.) *1
] : Data clear
10
●
Flow Chart
Channel Setting Mode
Self programming mode
TK-272G
REALIGNMENT
8-3. Function Setting Mode
This is a mode for using the panel keys to make function
settings without using the FPU, that operate on all channels.
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
[Side2]
Channel set modeChannel selection
RX frequency
RX signaling
TX freguency
TX signaling
option signaling
Busy channel lockout
Best Shift yes/no
RF Power High/Low
Wide/Narrow
Scan delete/add
Priority channel
Home channel
Compander yes/no
Begin of TX ID
End of TX ID
ID
PTT ID
[Side2]
[2]
[2]
[
Side1
[2]/[3]
[
Side1
[2]/[3]
Side1
[
[2]/[3]
Side1
[
[2]/[3]
[2]/[3]
[
Side1
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
Not used when (Scan) Priority is not Fixed.
[2]/[3]
Not used when Home Channel is not set in key Assignment.
[2]/[3]
[2]/[3]
[2]/[3]
[
Side1
[2]/[3]
[
Side1
[2]/[3]
Channel Delete
OFF
]
OFF
]
OFF
]
OFFQTDQT NDQT I
]
Data clear
]
Data clear
]
Data clear
]
QTDQT NDQT I
[Side1]
[Side1]
Not valid if Dial ID=Disable
and PTT ID=off, or EOT is set.
Not valid if Dial ID=Disable
and PTT ID=off, or BOT is set.
[
[Side1]
[
[Side1]
Side1
]
Side1
]
[ ]
[ ]
Pressing the [Side1] when "SELF" is displayed, sets the
Function Setting Mode.
Select an item set using [3] then change the selection with
the encoder.
The data displayed using [2] is stored in the memory and
then proceeds to the next item. Pressing [3] proceeds to
the next item without storing it in the memory.
Press [Side1] to display "SELF" and return to reset (default)
status.
Function Setting Mode
No.
Function ChoicesDisplayRemarks
Function Key
1
[Side1]
No Function
Talk Around
Display Character
Home Channel
Channel Down
LAMP_OFF Default
LAMP_3
LAMP_5
LAMP_7
LAMP_8
Channel Up LAMP_9
KeylockLAMP_10
LampLAMP_11
RF Power Low
ScanMON_22
Scan DEL/ADD
Operator
Selectable Tone
No Function KEY1_OFF
Talk Around KEY1_3
Display Character
Home Channel
Channel Down
Channel Up KEY1_9
KeylockKEY1_10
LampKEY1_11
2-Tone Encode
Select
Monitor AKEY1_17
Monitor BKEY1_18
Monitor CKEY1_19
Monitor DKEY1_20
RF Power Low
ScanKEY1_22
Scan DEL/ADD
Operator
Selectable Tone
No Function KEY2_OFF
Talk Around KEY2_3
Display Character
Home Channel
Channel Down
Channel Up KEY2_9
KeylockKEY2_10
LampKEY2_11
2-Tone Encode
Select
Monitor AKEY2_17
Monitor BKEY2_18
Monitor CKEY2_19
Monitor DKEY2_20
RF Power Low
ScanKEY2_22
Scan DEL/ADD
Operator
Selectable Tone
]
No Function KEY3_OFF
Talk Around KEY3_3
Display Character
Home Channel
Channel Down
MON_21
MON_23
MON_27
KEY1_5
KEY1_7
KEY1_8
KEY1_16
KEY1_21
KEY1_23 Default
KEY1_27
KEY2_5
KEY2_7
KEY2_8
KEY2_16
KEY2_21
KEY2_23
KEY2_27
Default
KEY3_5
KEY3_7
KEY3_8
REALIGNMENT
No.
Function ChoicesDisplayRemarks
5[2
]
6
[3]
7 [CH]
8
Power On Tone
9
Control Tone
10
Warning Tone
11
Time Out Timer
TOT
12
Pre-Alert Time
TOT
13
Rekey Time
TOTOFF1-15/
14
Reset Time
15
Clear to Transpond
(BCL for Transpond)
Channel Up KEY3_9
KeylockKEY3_10
LampKEY3_11
2-Tone Encode
Select
Monitor AKEY3_17
Monitor BKEY3_18
Monitor CKEY3_19
Monitor DKEY3_20
RF Power Low
ScanKEY3_22
Scan DEL/ADD
Operator
Selectable Tone
No Function KEY4_OFF
Talk Around KEY4_3
Display Character
Home Channel
Channel Down
Channel Up KEY4_9
KeylockKEY4_10
LampKEY4_11
2-Tone Encode
Select
Monitor AKEY4_17
Monitor BKEY4_18
Monitor CKEY4_19
Monitor DKEY4_20
RF Power Low
ScanKEY4_22
Scan DEL/ADD
Operator
Selectable Tone
Channel Up/Down
No Function