Kenwood TK-260G, TK-270G Service Manual

VHF FM TRANSCEIVER
TK-260G/(N)/270G/(N)
SERVICE MANUAL
5 TONE
Knob (PTT) (K29-5334-13)
Knob (Side1) (K29-5333-13)
REVISED
Knob (CHANNEL SELECTOR) (K29-5341-03)
Knob (VOL) (K29-5332-03)
Antenna (T90-0695-15):E,(N)E (T90-0680-05):(N)T (T90-0681-05):(N)E2
Cabinet assy (A02-2391-23)
Knob (PTT) (K29-5334-13)
Knob (Side1) (K29-5333-13)
© 2003-02 PRINTED IN JAPAN
B51-8554-10 (S) ∗∗∗
Knob (ENC) (K29-5331-03)
Knob (VOL) (K29-5332-03)
Cabinet assy (A02-2385-23)
TK-260G
CONTENTS
GENERAL ......................................................................2
SYSTEM SET-UP .......................................................... 2
OPERATING FEATURES..............................................3
DISASSEMBLY FOR REPAIR..................................... 15
CIRCUIT DESCRIPTION .............................................16
SEMICONDUCTOR DATA ..........................................20
DESCRIPTION OF COMPONENTS............................ 22
PARTS LIST.................................................................23
EXPLODED VIEW .......................................................31
PACKING .....................................................................33
Key top (DTMF) (K29-5330-02)
TK-270G
ADJUSTMENT .............................................................34
PC BOARD VIEWS
DISPLAY UNIT (X54-3250-10)............................... 45
TX-RX UNIT (X57-587X-XX)..................................47
SCHEMATIC DIAGRAM .............................................. 53
BLOCK DIAGRAM ....................................................... 61
LEVEL DIAGRAM ........................................................ 63
KNB-14/KNB-15A (Ni-Cd BATTERY) ..........................64
OPTIONS .....................................................................65
SPECIFICATIONS ................................... BACK COVER
TK-260G/(N)/270G/(N)
GENERAL / SYSTEM SET-UP
INTRODUCTION
SCOPE OF THIS MANUAL
This manual is intended for use by experienced technicians familiar with similar types of commercial grade communications equipment. It contains all required service information for the equipment and is current as of the publication date. Changes which may occur after publication are covered by either Service Bulletins or Manual Revisions. These are issued as required.
ORDERING REPLACEMENT PARTS
When ordering replacement parts or equipment information, the full part identification number should be included. This applies to all parts, components, kits, or chassis. If the part number is not known, include the chassis or kit number of which it is a part, and a sufficient description of the required component for proper identification.
Unit
Model &
destination
TK-260G
TK-270G
(N)E,(N)T
(N)E2 X57-5872-75 136~150MHz
(N)E,(N)T
TX-RX Unit Display Unit Frequency range Remarks Helical Antenna Charger Battery 16 Key
E X57-5872-71
X57-5872-72 _
E X57-5872-73
X57-5872-74
X54-3250-10 146~174MHz
146~174MHz
PERSONNEL SAFETY
The following precautions are recommended for personnel
safety:
DO NOT transmit until all RF connectors are verified secure and any open connectors are properly terminated.
SHUT OFF and DO NOT operate this equipment near electrical blasting caps or in an explosive atmosphere.
This equipment should be serviced by a qualified technician only.
SERVICE
This radio is designed for easy servicing. Refer to the schematic diagrams, printed circuit board views, and alignment procedures contained within.
NOTE
The terms “Wide” and “Semi wide” used in this service manual correspond to “Wide 5K” and “Wide 4K” respectively that appear in the menu and help texts of the KPG-67D (Field Programming Unit).
IF1 : 49.95MHz LOC : 50.4MHz
O
OP OP
_
O

SYSTEM SET-UP

Choose the type of transceiver
Are you using the speaker microphone?
2
Merchandise received
Transceiver programming
NO
Delivery
Frequency range (MHz) RF power Type
TX/RX 136~150
TX/RX 146~174
TX/RX 146~174
A personal computer (IBM PC or compatible), programming interface (KPG-22), and programming software (KPG-67D) are required for programming. (The frequency, TX power HI/LOW, and signalling data are programmed for the transceiver.)
YES
KMC-17 or KMC-21
Speaker microphone
(Option)
5.0W
5.0W
5.0W
TK-260G (N)E2
TK-260G E TK-270G E
TK-260G (N)E,(N)T
TK-270G (N)E,(N)T
TK-260G/(N)/270G/(N)

OPERATING FEATURES

1. Operation Features
• TK-260G
Channel selector
Rotate to select a channel (1 ~ 8).
Antenna
LED indicator
Lights red while transmitting. Lights green while receiving. Flashes orange while receiving a 2-Tone 5­Tone or DTMF signal that matches the one set up in your transceiver. Flashes red when the battery power is low while transmitting.
PTT (Push-to­Talk) switch
Press this switch, then speak into the microphone to call a station.
Side 1 key
Press to activate its programmable function.
Side 2 key
Press to activate its programmable function.
Programmable Auxiliary Functions Side 1 key and Side 2 key can each be programmed
with one of the following auxiliary functions:
Squelch Momentary: Press and hold the Monitor key to hear background noise. Release the key to return to normal operation.
Squelch Off: Momentarily press the Monitor key to hear background noise. Press the key again to return to normal operation.
Monitor Momentary
· Model = DTMF/ 2tone:
While pressing this key, “ ” appears and the squelch unmutes if a carrier is present, regardless of the specified Signalling (including Option Signalling). If released, “ ” disappears, and the squelch mutes.
· Model = 5tone:
Depend on Monitor Function in the 5 Tone Parameters. You can select either QT/DQT or 5tone decoding to be canceled while pressing Monitor key. When Monitor function is activated, “ ” icon appears.
Power switch/ Volume control
Tur n clockwise to switch ON the transceiver. Rotate to adjust the volume. To switch OFF the transceiver, turn counterclockwise fully.
Microphone
Speaker
SP/MIC jacks
Connect an optional speaker/ microphone here.
The transceiver is shown with the optional KNB-14 battery pack.
Monitor
· Model = DTMF/ 2tone:
When this key pressed once ,“ ” icon lights and squelch unmutes if a carrier is present, regardless of the specified Signalling (including Option Signalling). If pressed again, “ ” icon goes off and squelch mutes.
· Model = 5tone:
Depend on Monitor Function in the 5 Tone Parameters. You can select either QT/DQT or 5tone decoding to be canceled when Monitor key is pressed. When Monitor function is activated, “ ” icon appears.
None: No function.
RF Power Lo: Press the RF Power Lo key to toggle the output power of a channel between high and low. This can only be used for channels that have been programmed with high power. Pressing RF Power Lo while using a channel programmed with low power causes an error tone to sound. (When changing a channel from high to low power, all channels programmed with high power are changed to low.)
2-Tone Encode Select: To transmit using a 2-Tone code, press the PTT switch and the 2-Tone Encode Select key, then speak into the microphone in your normal voice. Release the PTT switch and 2-Tone Encode Select key to receive.
• TK-270G
Antenna
ee
ww
qq
e
w
q
ee
ww
qq
Microphone
Speaker
rr
r
rr
oo
o
tt
t
tt yy
y
yy uu
u
uu
A321
ii
i
ii
The transceiver is shown with the optional KNB-14 battery pack.
qq
q Rotary encoder
qq
B654
C987
D
0
oo
!0!0
!0
!0!0
Your dealer can program the encoder as either Group Up/Down or Channel Up/Down (default setting). Rotate to select a group or channel. Also rotate to adjust the squelch in Squelch Adjustment mode.
ww
w LED indicator
ww
Lights red while transmitting. Lights green while receiving. Flashes orange while receiving a Code Squelch or a Selective Call code, or a 2-Tone 5­Tone or DTMF signal that matches the one set up in your transceiver. Flashes red when the battery power is low while transmitting.
3
TK-260G/(N)/270G/(N)
OPERATING FEATURES
ee
e Power switch/ Volume control
ee
Turn clockwise to switch ON the transceiver. Rotate to adjust the volume. To switch OFF the transceiver, turn counterclockwise fully.
rr
r PTT (Push-to-Talk) switch
rr
Press this switch, then speak into the microphone to call a station.
tt
t Side 1 key
tt
This is a PF (Programmable Function) key. Press it to activate its auxiliary function (page 4).
yy
y Side 2 key
yy
This is a PF (Programmable Function) key. Press it to activate its auxiliary function (page 4).
uu
u
uu
22
33
, •,
2,
3 keys
22
33
°
These are PF (Programmable Function) keys. Press each key to activate its auxiliary function.
ii
i DTMF keypad
ii
Used for storing and transmitting DTMF numbers.
oo
o SP/MIC jacks
oo
Connect an optional speaker/ microphone here.
!0!0
!0 Display
!0!0
(See page 5.)
Note: The PF keys are programmed with default functions:
Side 1 key: Lamp
Side 2 key: Monitor A
key: Scan
°
key: Scan Del/Add
22
2
key: Talk Around
22
33
3
key: RF Power Lo
33
Programmable Auxiliary Functions Side 1, Side 2, °, •,
22
2, and
22
33
3 can be programmed
33
with the auxiliary functions listed below.
• Channel Down
• Channel Up
• Display Character
• Group Down
• Group Up
• Home Channel
• Key Lock
• Lamp
• Squelch Momentary
• Squelch Off
• Monitor Momentary
• Monitor
• None
• Redial
• RF Power Lo
• Scan
• Scan Del/Add
• Talk-Around
• 2-Tone Encode Select
• Call 1 (5-Tone only)
• Call 2 (5-Tone only)
• Sel call Entry
4
2. Programmable keys
described in the following sections.
1) Channel up/down (TK-270G only)
2) Display character (TK-270G only)
3) Group up/down (TK-270G only)
4) Home Channel (TK-270G only)
5) Key lock (TK-270G only)
6) Lamp (TK-270G only)
7) Monitor
8) 2-Tone Encode Select (TK-270G only)
1 Press the key programmed as 2-tone Encode Select.
2 Press the key programmed as Rotary encoder to select
3 Press PTT switch and 2-Tone Encode Select key to transmit
9) Redial (TK-270G only)
The functions the FPU programs to the function keys are
When the key is pressed each time, the channel number to be selected is incremented/decremented and repeats if held for one second or longer.
This key switches the LCD display between the group/ channel number and group/channel name.
When the key is pressed each time, the group number to be selected is incremented/decremented and repeats if held for one second or longer.
Press this key once, the channel switches to the pre­programmed home channel.
When the KEY LOCK switch is held down for one second or more, keys other than [PTT], [Side1], [Side2], [VOL], [POWER], and KEY LOCK are locked. When 12/16 KEY LOCK is set with the FPU, the DTMF key is locked and when front-panel KEY LOCK is set, the DTMF key and the [PF] key are locked.
This key illuminates the LCD and keys on the front panel. When the key is pressed, the LED lamp goes on. When it is released, the lamp goes off after about five seconds. If any key is pressed while the LED lamp is on, the lamp is kept on for five seconds.
Used to release signalling or squelch when operating in conventional mode. It is also used to reset option signalling.
• A pre-programmed 2-tone code name appears on the
display.
you desired 2-tone code name.
and release them to receive.
Pressing this key when Group/Channel is shown, displays the previously transmitted DTMF code. Pressing [PTT] at this time, transmits the code that is currently displayed.
TK-260G/(N)/270G/(N)
OPERATING FEATURES
10) RF power low
Used to temporarily switch transmission output to low power. Turning the function on enables:
HiLow, LowLow Key states are backed up, except in the PC mode when they are reset.
11) Scan (TK-270G only)
Pressing this key starts scanning. Pressing this key again stops scanning.
12) Scan Del/Add (TK-270G only)
This key switches the currently displayed channel between "Delete" and "Add". The "Add" channel is contained in the scan sequence, the "Delete" channel is not contained. In the scan mode, this key switches the channel between delete or add, temporarily.
13) Talk Around (TK-270G only)
Press this key, the transceiver uses the receive frequency and tone for transmission. The operator can call the other party directly (without repeater). Press this key again, the talk around function goes off.
14) None
An error operation beep sounds, and no action will occur. Use this function when the transceiver is required to be operated more simply.
15) Call 1 to 2 (5tone only)
Press the [CALL #] key to transmit the 5tone code that is programmed to “Call #” in the Channel Data.
16) Selcall Entry
Press [Selcall Entry] key to enter the desired Selcall code you want to call. When you enter Selcall Entry mode, the “TX Address” number appears on the LCD.
To enter Selcall number, use the keypad . You can also
use the channel selector to select the number.
3. Display (TK-270G only)
Icon Description
Not used on this transceiver. Appears when the selected channel is
busy. Appears when QT, DQT, DTMF, 5-Tone or 2-Tone decoding is deactivated (by pressing the Monitor key). Appears when you receive a Code Squelch, Selective Call, 2-Tone, or DTMF Signalling call. Also appears when you transmit using Code Squelch or Selective Call.
Appears while scanning. Appears when using low power on the
selected channel. Appears when the selected channel is included in the scanning sequence. Displays the selected channel, the squelch level, DTMF digits (when entering digits, confirming digits, or making a call), and messages received via Selective Call.
4. Scan Operating (TK-270G only)
1) Scan types
Single Group Scan
You can scan all valid (ADD) channels in the displayed group
that can be selected with the group selector.
Multiple Group Scan
You can scan all valid (ADD) channels in all valid (ADD)
groups.
2) Scan Start Condition
One or more non-priority channels must be added to all channels that can be scanned. The transceiver must be in normal receive mode (PTT off).
When you activate the key programmed to the scan function, scan starts. The scan icon ("SCN") lights and "SCAN" is indicated on display.
5
TK-260G/(N)/270G/(N)
OPERATING FEATURES
3) Scan Stop Condition
The scan stops temporarily if the following conditions are satisfied. 1 The receiving signal matches the signalling code in your
radio that is set by the programming software (KPG-67D).
2 When the Monitor key is depressed.
4) Scan Channel Types
1 Priority channel is the most important channel for scan,
and always detects a signal during scan and when the scan stops temporarily.
2 Non-priority channels detect a signal during scan. For the
channels that can be selected with the group or channel selector when the scan does not occur, the "A" icon lights.
5) Priority Channel Setting
A priority channel can be set as follows with the programming software (KPG-67D).
1 Specify a priority channel as a fixed priority channel. 2 Make a selected channel a priority channel.
Specify the initial channel before the operator changes it.
6) Scan Type According to the Priority Channel
1 When no priority channel is set : Only the non-priority
channels are scanned.
If a non-priority channel stops temporarily, it stops until
there is no signal on the channel.
2 When priority channel is set : Either priority channel is
scanned.
If a non-priority channel stops temporarily, a priority channel
signal is detected at certain intervals.
If a priority channel stops temporarily, it stops until there is
no signal on the priority channel.
6 Selected with talkback
The transceiver reverts to the channel before scanning or
the channel that you changed during scan.
8) Scan End
When you reactivate the key programmed to the scan
function during scan mode, scan ends.
The scan icon ("SCN") and "SCAN" or revert channel
(programmable) display goes off.
9) Temporarily Delete/Add
It is possible to delete or add a channel temporarily during scan. When scan stops on an unnecessary channel, for example by interference of the other party, press the delete/ add key, then that channel is deleted temporarily and scan will re-start immediately.
When you would like to add a deleted channel temporarily to the scan sequence, select the desired (deleted) channel during scan, and press the delete/add key before scan re-starts.
That channel is added temporarily to the scan sequence. The temporarily deleted or added channels are returned to their pre-set delete/add conditions when the transceiver exits from scan mode.
5. Details of Features
1) Time-out timer
The time-out timer can be programmed in 15 seconds increments from 15 seconds to 300. If the transmitter is keyed continuously for longer than the programmed time, the transmitter is disabled and a warning tone sounds while the PTT button is held down. The alert tone stops when the PTT button is released.
7) Revert Channel
The revert channel is used to transmit during scanning and set by the programming software (KPG-67D). 1 Priority
The transceiver reverts to the priority channel.
2 Priority with talkback
The transceiver reverts to the priority channel.
If you press PTT during a resume timer (dropout delay time, TX dwell time) or calling, you can transmit on the current channel to answer to the call however revert channel is set to priority channel.
After resume time, scan re-starts and the transmission channel returns to the priority channel.
3 Selected channel
The transceiver reverts to the channel before scanning or the channel that you changed during scan.
4 Last called channel
The transceiver reverts to the last called channel during scan.
5 Last used channel
The transceiver reverts to the last used (transmitted) channel during scan. "Last used" revert channel includes
6
talkback function.
2) Selective Call Alert LED
You can select whether or not the LED on the transceiver
flashes orange when selective call has occurred.
3) PTT ID
PTT ID provides a DTMF ANI to be sent with the PTT button every time it is used (Begin of TX ID at beginning of transmission, End of TX ID at end of transmission, or both).
You can program the PTT ID as one of the followings.
Off, BOT (Begin of TX ID), EOT (End of PTT ID), BOTH.
The contents of ID are programmed for each channel.
The transceiver is capable of having ID. The format is DTMF.
The timing that the transceiver sends the ID is programmable.
Begin of TX ID (BOT) : Begin of TX ID is sent at the
beginning of transmission.
End of TX ID (EOT) : End of TX ID is sent at the end of
transmission.
Both : Begin of TX ID is sent at the beginning of transmission
and End of TX ID is sent at the end of transmission.
There is also a "PTT ID" setting for each channel.
TK-260G/(N)/270G/(N)
OPERATING FEATURES
4) Battery Warning
This transceiver has a battery warning feature. If low voltage is detected during transmission, the transceiver warns you by a flashing red "LED".
When the voltage is detected to be even lower during transmission, the transceiver stops transmission and warns you by a flashing red "LED" and a beep.
Please notice "indication" for the battery exchange, charging time by flashing red LED and beep.
5) "TOT" Pre-Alert
The transceiver has a "TOT" pre-alert timer. This parameter selects the time at which the transceiver generates a "TOT" pre-alert tone before the "TOT" is expired.
"TOT" will expire when the selected time passes from the TOT pre-alert tone.
6) "TOT" Re-Key Time
The transceiver has a "TOT" re-key timer. This timer is the time you cannot transmit after the "TOT" is exceeded. After the "TOT" re-key time expires you can transmit again.
7) "TOT" Reset Time
The transceiver has a "TOT" reset timer. This timer is the minimum wait time allowed during a transmission that will reset the "TOT" count.
"TOT" reset time causes the "TOT" to continue even after the PTT is released, unless the "TOT" reset timer has expired.
6. Option Signalling (DTMF/2 tone)
Built-in DTMF decoder is available for option signalling. Built-in 2-Tone decoder is available for option signalling.
It is possible to use individual call, group call, DBD (Dead
Beat Disable). Note : DBD is only DTMF
Preset operation is triggered when there is a match with
Option Signaling.
When Option Signaling matches on a Group Channel where it is set to Yes, the Option Signaling display flashes and Option Signaling is canceled. Settings after this will cause "Transpond" or "Alert" to sound.
Setting the Selective Call Alert LED will cause the LED to start flashing orange.
Mute or Unmute is triggered by the ID/QT/DQT/Carrier when option signaling matches (when Option Signal is deactivated by a transmission).
AND/OR
Option Signaling match conditions can be selected with AND/OR logic.
Alert/Transpond AF Mute Open
AND
Triggers at match with QT/ Triggers at match with QT/ DQT/ID+DTMF(2tone);Opt
OR Triggers at match with
DTMF(2tone) ; Opt
DQT/ID+DTMF(2tone); Triggers only for match with QT/DQT/ID;Signaling
Opt
8) OST (Operator Selectable Tone) (TK-270G K types only)
The transceiver is capable of having the "OST" function
and 16 tone pairs (QT/DQT) with a max 10-digit name for each tone pair.
9) Clear to Transpond
The transceiver waits for an acknowledment signal until the
channel free.
This feature ensures the acknowledment signal is receive
by another party.
10) Battery Save
This is the automatic battery saver during standby mode
operation. The receiver circuit is turned on and off to conserve the battery life.
Even if set as OR, there is no Alert/Transpond just with
DTMF.
Even if set as OR, AF mute cannot be canceled just by a
match with DTMF.
In conventional channels not set with QT/DQT, signaling is
a match just by receiving the carrier.
Auto Reset
When Option Signaling matches on a Group channel where it is set to Yes, Option Signaling is canceled when it matches a group channel set to Yes.
After Option Signaling matches, Option Signaling can automatically Reset after a specified time.
Dead Beat Disable
When the D.B.D (Dead Beat Disable) code matches, a preset operation is performed.
When D.B.D matches on all group channels regardless of whether Option Signaling = Yes/No, then TX Inhibit or TX RX Inhibit is activated by the settings performed afterwards. D.B.D is canceled when the D.B.D. code + "#" is received.
Transpond is always activated when the D.B.D code matches. Alert is not output. An Option Signaling match is not displayed.
7
TK-260G/(N)/270G/(N)
OPERATING FEATURES / REALIGNMENT
7. Audible user feedback tones
The transceiver outputs various combinations of tones to notify the user of the transceiver operating state. The main tones are listed below
The high tone is 1477Hz, the mid tone is 941Hz, and the low tone is 770Hz.
• Power on tone
This tone is output when the transceiver is turned on. (The high tone is output for 500ms.)
• Alert tone
This tone is output when the transceiver is in TX inhibition for TOT, battery warning and PLL unlocked. It is output until the PTT button is released. (The 697Hz tone is output.)
• Busy Tone
This informs the user of a busy channel lock out
• Group Call Tone
The group call tone informs the user of a group call in DTMF/
2 Tone Option Signaling. This tone repeats 7 times.
770Hz 770Hz
30ms 30ms 30ms
• Individual Tone
Individual tone is issued on receiving selective call by DTMF/
2 Tone Option Signaling.
2000Hz 2000Hz 2000Hz
100ms 100ms 100ms 100ms 100ms
• Pre Alert tone
Informs the user when nearing transmit inhibit (transmit cutoff) time due to TOT.
The Pre Alert Tone is issued from the time set for TOT Pre Alert until the TOT triggers.
1633Hz 1633Hz 1633Hz
50ms 50ms 50ms 50ms 50ms
8. 5 tone Standard
The selected 5 tone Standard is used for 5 tone encoding and decoding.
Range:
ZVEI, CCIR, EEA, ZVEI-2, EIA, KENWOOD.

REALIGNMENT

1. Modes
User mode
Panel test mode
(TK-270G only)
PC mode
Firmware programming mode
Clone mode
Self programming mode (TK-270G only)
Mode Function
User mode For normal use. Panel test mode Used by the dealer to check the
Panel tuning mode Used by the dealer to tune the radio. PC mode Used for communication between the
Data programming Used to read and write frequency data mode PC test mode Used to check the radio using the PC.
Firmware program- Used when changing the main ming mode program of the flash memory. Clone mode Used to transfer programming data
Self programming Frequency, signalling and features. mode
Panel tuning mode
Data programming mode
PC test mode
Checksum
fundamental characteristics.
radio and PC (IBM compatible).
and other features to and from the radio.
This feature is included in the FPU. See panel tuning.
from one radio to another.
PC tuning mode
2. How to Enter Each Mode
Mode Operation
User mode Power ON Panel test mode
PC mode Received commands from PC Panel tuning mode [Panel test mode]+[°] Firmware programming mode
Clone mode [Side1]+[3]+Power ON
Self programming mode [Side1]+[
[2]+Power ON (Two seconds) (TK-270G only)
[Side1]+[Side2]+Power ON (Two seconds)
(Two seconds)
]+Power ON
(Two seconds) (TK-270G only)
3. For the panel Test Mode (TK-270G only)
For the setting method, refer to ADJUSTMENT.
3-1. For the panel Tuning Mode
For the setting method, refer to ADJUSTMENT.
8
TK-260G/(N)/270G/(N)
REALIGNMENT
4. Checksum
Executing this function, "TUNING" appears on the display
of TK-270G while calculating the checksum .
When the calculation is completed, the display returns to
normal and PC displays the checksum of the radio.
5. PC Mode
5-1. Preface
The TK-260G/270G transceiver is programmed using a personal computer, a programming interface (KPG-22) and programming software (KPG-67D).
The programming software can be used with an IBM PC or compatible. Figure 1 shows the setup of an IBM PC for programming.
5-2. Connection procedure
1. Connect the TK-260G/270G to the personal computer with
the interface cable.
2. When the POWER is switched on, user mode can be
entered immediately. When the PC sends a command, the radio enters PC mode. When data is transmitted from transceiver, the red LED blinks. When data is received by the transceiver, the green LED blinks.
IBM-PC
Notes:
• The data stored in the personal computer must match the model type when it is written into the flash memory.
• Change the TK-260G/270G to PC mode, then attach the interface cable.
5-3. KPG-22 description
(PC programming interface cable: Option)
The KPG-22 is required to interface the TK-260G/270G to the computer. It has a circuit in its D-subconnector (25-pin) case that converts the RS-232C logic level to the TTL level.
The KPG-22 connects the SP/MIC connector of the TK­260G/270G to the computers RS-232C serial port.
5-4. Programming software description
The KPG-67D programming disk is supplied in 3-1/2” disk format. The software on this disk allows a user to program the TK­260G/270G radios via a programming interface cable (KPG-22).
5-5. Programming with IBM PC
If data is transferred to the transceiver from an IBM PC with the KPG-67D, the destination data (basic radio information) for each set can be modified. Normally, it is not necessary to modify the destination data because their values are determined automatically when the frequency range (frequency type) is set.
The values should be modified only if necessary. Data can be programmed into the flash memory in RS-232C format via the universal connector.
KPG-67D installation manual part No. : B62-1153-XX
KPG-67D
RF Power meter or SSG
6. Firmware Programming Mode
6-1. Preface
Flash memory is mounted on the TK-260G/270G. This allows the TK-260G/270G to be upgraded when new features are released in the future. (For details on how to obtain the firmware, contact Customer Service.)
6-2. Connection procedure
Connect the TK-260G/270G to the personal computer (IBM PC or compatible) with the interface cable (KPG-22). (Connection is the same as in the PC Mode.)
KPG-22
+
SP
}
-
+
MIC
}
-
Tuning cable (E30-3216-05)
Gray Gray/Black
1.5D-XV Lead wire Gray-XV Shield wire
Fig. 1
6-3. Programming
1. Start up the programming software (KPG-67D), select "firmware program" in the "Program" item, and press the Return key on your personal computer. This starts up the firmware programmer.
2. The top screen is displayed. Press any key to advance to the next screen.
3. Set the communications speed (normally, 57600 bps) and communications port in the Setup item.
4. Set the firmware to be updated by File select (=F1).
5. Hold down the [Side1] and [Side2] switches on the TK-260G/ 270G, and press the power switch. When the [Side1] and [Side2] switches are held down for two seconds, "PROG576" appears on the display and the LED lights orange. When "PROG576" is displayed, release the switches (TK-270G only).
9
TK-260G/(N)/270G/(N)
REALIGNMENT
6. Check the connection between the TK-260G/270G and the personal computer, and make sure the TK-260G/270G is in Program mode.
7. Press F10 on the personal computer. A window opens on the display to indicate the writing progress. When the TK­260G/270G begins to receive data, the LED lights green.
8. When data is received successfully, a checksum appears on the display.
(Since the TK-260G does not have a display, check the checksum with the FPU (KPG-67D).)
9. If you want to continue programming other TK-260G/ 270Gs, repeat steps 5 to 8.
Notes:
To start the Firmware Programmer from KPG-67D, the Fpro path must be set up by the KPG-67D Setup.
This mode cannot be entered if the Firmware Programming mode is set to Disable in the Programming software (KPG-67D).
7. Clone Mode
Programming data can be transferred from one radio to another by connecting them via their SP/MIC connectors. The operation is as follows (the transmit radio is the master and the receive radio is the slave).
When programming the firmware, it is recommend to copy the data from the floppy disk to your hard disk before you update the radio firmware. Directly copying from the floppy disk to the radio may not work because the access speed is too slow.
6-4. Function
1. If you press the [Side2] switch while "PROGXXX" is displayed, the checksum is displayed. If you press the [Side2] switch again (while the checksum is displayed), "PROGXXX" is redisplayed.
2. A transmission speed can be selected by pressing the [Side1] switch while "PROGXXX" is displayed.
19200 bps: The LED flashes green and red alternately. 38400 bps: The LED flashes orange. 57600 bps: The LED lights orange.
Note:
Normally, write in the high-speed mode.
1. Turn the master TK-270G power ON with the [Side1]+[3] keys held down. The TK-270G displays "
2. Power on the slave TK-260G/270G.
3. Connect the cloning cable to the SP/MIC connectors on the master and slave.
4. Press the [ "
CLONE ". The data of the master is sent to the slave. While the slave is receiving the data, "-PC-" is displayed. When cloning of data is completed, the master displays "END", and the slave automatically operates in the User mode. The slave can then be operated by the same program as the master.
Slave TK-260G TK-260G TK-260G TK-762G TK-760G
Master
TK-270G
E
TK-270G
(N)E
TK-270G
(N)T
] key on the master while the master displays
°
E(N)E(N)TE(N)E
TK-270G TK-270G TK-270G TK-762G
E(N)E(N)T(N)E
OK N/A N/A OK N/A
N/A OK N/A N/A OK
N/A N/A OK N/A N/A
CLONE ".
5. The other slave can be continuously cloned. When the [
Note: Use the new cloning cable for TK-260G/270G.
Note: You can clone the programmed data between the
key on the master is pressed while the master displays "END", and the slave the master displays " Carry out the operation in steps 2 to 4.
You cannot use the old cloning cable for TK-260/270.
transceiver listed below. Frequency version must be same. Cloning cable parts No.
E30-3410-05 (TK-270G → TK-260G/270G) E30-3411-05 (TK-270G → TK-760G/762G)
CLONE ".
°
]
10
Loading...