5 W (136-174 MHz) Models
•
5 W (400-470, 450-520 MHz) Models
•
• 512 CH-GID / 128 Zones
• 12-Key Keypad Models
14 Character Alphanumeric Aliases
•
• Backlit Dot Matrix LCD
3-Digit Sub-Display
•
• Function/Status LCD Icons
RSSI Indicator
•
• Date & 12/24 Hour Time Clock
• Transmit/Busy/Call Alert/Warn LED
• On/Off Volume Knob
• 16-Position Mechanical Selector
• 6 Front PF & Menu Keys
• 2 Side PF Keys
• Emergency/AUX Key
• 500 mW Speaker Audio
• VOX Ready
• Emergency Call Features
• Emergency Man-Down Option
• Lone Worker
• Multi-Language Display
• Programmable TX/RX Indication (On/Off)
• Special Alert Tone Patterns
• Time Out Timer
• Busy Channel Lockout
• LCD Battery Status Indicator
• Low Battery Alert
• Battery Saver
• Weather-sealed ACC Connector
• MIL-Spec Speaker Mic Options
• KMC-38GPS Speaker Mic Option
• KPG-111D Windows
• Flash Firmware Upgrading
®
FPU
• Front Panel Test & Tune
• Cloning
• MIL-STD-810 C/D/E/F
• MIL-STD “Driven-Rain”
• IP-54/55 Water & Dust Intrusion
• Easy Option Port
• PC Serial Interface
• SDM Manual Input
• Transparent Data Mode
1
1
• Intrinsically Safe Option
• VGS-1 Voice Guide/ Voice & GPS Data
Storage Option
DIGITAL – COMMON
• NXDN®Digital Air Interface
• AMBE+2
• 6.25 & 12.5 kHz Channels
• Over-the- Air Alias
• Paging Call
• Emergency Call
• All Group Call
• Status Messaging
• Remote Stun/Kill
• Remote Check
™
VOCODER
1
1
1
• Short & Long Data Messages
GPS Location with Voice
•
®
NXDN
•
crambler Included (Conventional: per CH)
S
1
1
DIGITAL – CONVENTIONAL MODE
64 Radio Access Numbers (RAN)
•
• DTMF (Encode/Decode)
Individual & Group Selective Call
•
• Mixed FM/Digital Operation
DIGITAL – TRUNKING MODE
• Individual Private Call
• Group Call
• Broadcast Call
• Transmission Trunked Mode
• Message Trunked Mode
• Call Queuing with Priority
• Call Queue Pre-emption
• Late Entry (UID & GID)
• 4 Priority Monitor ID’s
• Remote Group Add
2
2
2
2
2
2
1
• Failsoft Mode
• Multi-Site IP Network Compatible
SCAN
• Single Zone / Multi-Zone / List Scan
• Dual Priority Scan (Conventional)
FM MODES – GENERAL
• 25 & 12.5 kHz Channels
• FleetSync
• DTMF Encode / Decode
• Companded Audio
• Voice Inversion Scrambler
• Encryption/ANI Board Control
®
/II
FM CONVENTIONAL ZONES
• QT / DQT
• Two-Tone Decode
• Single/Two-Tone Encode
• Call Key 1-6
• Operator Selectable Tone
FM LTR®TRUNKED ZONES
• Kenwood LTR®Features
FleetSync®/II (FM)
• PTT ID Digital ANI
• Selective Call & Group Call
• Status Messaging
• Emergency Status
• Caller ID Display
• Short Text Messages
• Power On/Off Status Messages
• Send/Display GPS (KMC-38GPS)
• PTT ID & Emergency GPS Reporting
• Status Message Block GPS Reporting
1
1
1
1
1
1
http://nexedge.kenwood.com
Options
■ KNB-47L
i-Ion Battery
L
1950mAh)
(
■ KNB-48L
i-Ion Battery
L
(2550mAh)
■ KNB-50NC
Ni-MH Battery
(2000mAh) Intrinsically Safe
■ KSC-32
ri-Chemistry Rapid
T
ate Charger
R
■ KSC-326
Rapid Rate Six Unit Charger
for Ni-Cd/Ni-MH/Li-ion
KNB-48L
■ KMC-41M
IL-STD & IP 54/55
M
peaker Microphone
S
■ KMC-38GPS
GPS Speaker
Microphone
■ KHS-11
eavy Duty Earphone
H
■ KEP-1
Heavy Duty Earphone
Main Specifications
GENERAL
requency Range Type 1 136-174 MHz 450-520 MHz
F
Number of Channels 512
Zones 128
ax. Channels per Zone 250
M
Channel Spacing Analog 12.5 / 15 / 25 / 30 kHz 12.5 / 25 kHz
perating Voltage 7.5V DC ± 20%
O
Battery Life ( with KNB-48L) 5-5-90 Approx. 14.5 hours
perating Temperature Range
O
Frequency Stability ± 2.0 ppm ± 1.0 ppm
Antenna Impedance 50
Dimensions (W x H x D) Projections not included
Weight (net) Radio only 8.82 oz (250 g)
FCC ID Type 1 ALH378400 ALH378500
IC Certification Type 1 282D-378400 282D-378500
ype 2 400-470 MHz
T
Digital 6.25 / 12.5 kHz 6.25 / 12.5 kHz
10-10-80 Approx. 9.0 hours
adio only
R
with KNB-47L
with KNB-48L
with KNB-47L 13.23 oz (375 g)
with KNB-48L 14.29 oz (405 g)
Type 2 ALH378501
Type 2 282D-378501
NX-200 NX-300
30˚ C to +60˚ C
22˚ F to +140˚ F (
-
-
Ω
.28 x 5.02 x 1.63 in (58 x 127.5 x 41.3 mm)
2
2.28 x 5.02 x 1.63 in (58 x 127.5 x 41.3 mm)
2.28 x 5.02 x 1.91 in (58 x 127.5 x 48.5 mm)
■ KRA-22/23
HF/UHF Helical Antenna
V
■ KRA-26/27
HF/UHF Whip Antenna
V
RA-16/17
■ K
HF/UHF Stubby Antenna
V
■ KRA-25
HF High Gain Antenna
V
ontact an authorized Kenwood dealer for details and complete list of all accessories and options.
C
■ KRA-28
HF Broad
V
and Antenna
B
■ VGS-1
oice Guide
V
Storage Unit
&
■ KBH-11
elt Clip (2.5")
B
All accessories and options may not be available in all markets.
NX-200 NX-300
RECEIVER
Sensitivity Digital @ 6.25kHz (3% BER) 0.20 µV
Selectivity Analog @ 25 kHz 72 dB
Intermodulation Distortion
Spurious Response Analog 70 dB
udio Distortion Less than 3%
A
Audio Output 500 mW / 8 Ω
TRANSMITTER
)
RF Power Output 5 W / 1 W
Spurious Response 70 dB
M Hum & Noise Analog @ 25 kHz 45 dB
F
Audio Distortion Less than 3%
Modulation 16K0F3E, 11K0F3E, 8K30F1E,
Analog meas urements made per TIA/E IA 603 and specifi cations shown are typical.
Kenwood reserves the right to change specifications without prior notice or obligation.
FleetSync®is a registered trademark of Kenwood Corporation.
®
LTR
is a registered trademark of Transcrypt International.
M
T
AMBE+2
is a trademark of Digital Voice Systems Inc.
®
Windows
is a registered trademark of Microsoft Corporation.
®
is a trademark of Kenwood Corporation and Icom Inc.
NXDN
M
T
NEXEDGE
is a trademark of Kenwood Corporation.
igital @ 12.5kHz (3% BER) 0.25 µV
D
Analog (12 dB SINAD) 0.25 µV
nalog @ 12.5 kHz 65 dB
A
Analog 70 dB (±50,100 kHz)
nalog @ 12.5 kHz 40 dB
A
8K30F1D, 8K30F7W, 4K00F1E,
4K00F1D, 4K00F7W, 4K00F2D
Applicable MIL-STD & IP
MIL Standard MIL 810C MIL 810D MIL 810E MIL 810F
Low Pressure 500.1/Procedure I 500.2/Procedure I, II 500.3/Procedure I, II 500.4/Procedure I, II
High Temperature 501.1/Procedure I, II 501.2/Procedure I, II 501.3/Procedure I, II 501.4/Procedure I, II
Low Temperature 502.1/Procedure I 502.2/Procedure I, II 502.3/Procedure I, II 502.4/Procedure I, II
Temperature Shock 503.1/Procedure I 503.2/Procedure I 503.3/Procedure I 503.4/Procedure I, II
Solar Radiation 505.1/Procedure I 505.2/Procedure I 505.3/Procedure I 505.4/Procedure I
Rain 506.1/Procedure I, II 506.2/Procedure I, II 506.3/Procedure I, II 506.4/Procedure I, III
Humidity 507.1/Procedure I, II 507.2/Procedure II, III 507.3/Procedure II, III 507.4
Salt Fog 509.1/Procedure I 509.2/Procedure I 509.3/Procedure I 509.4
Dust 510.1/Procedure I 510.2/Procedure I 510.3/Procedure I 510.4/Procedure I, III
Vibration 514.2/Procedure VIII, X 514.3/Procedure I 514.4/Procedure I 514.5/Procedure I
Shock 516.2/Procedure I, II, V 516.3/Procedure I, IV 516.4/Procedure I, IV 516.5/Procedure I, IV
International Protection Standard
Dust & Water Protection IP54/55
Methods/Procedures Methods/Procedures Methods/Procedures Methods/Procedures
Kenwood has always connected with people through sound. Now we want to expand the world of sound in ways that only Kenwood can,
listening to our customers and to the pulse of the coming age as we head toward a future of shared discovery, inspiration and enjoyment.
footnotes from Front:
1
Requires NX subscriber unit PC Serial
Interface compatible software application
(e.g Kenwood AVL & Dispatch Messaging
software) or hardware (e.g. console).
2
These trunked features are primarily
system programming and operational
dependent. Priority Monitor also requires
NX subscriber settings.
ADS#11309 Printed in USA