Kenwood NX-220, NX-320 User Manual

NX-220/320
NEXEDGE®VHF/UHF Digital & Analog Portable Radios
GENERAL FEATURES
W (136-174 MHz) Models
• 5
W (400-470, 450-520 MHz) Models
• 5
260 CH-GID / 128 Zones
4 CH-GID / 4 Zones (Non Display Version)
• 6
12-Key Keypad Models
8 Character Alphanumeric Aliases
acklit LCD & Keys
• B
Function/Status LCD Icons
ransmit/Busy/Call Alert/Warn LED
• T
On/Off Volume Knob
16-Position Mechanical Selector
4 Front PF Keys
3 Side PF Keys
Emergency/AUX Key
Built-in Motion Sensor
500 mW Speaker Audio
Zone/CH# Voice Announcement
KMC-48GPS Speaker Mic Option
KPG-141D Windows®FPU
Flash Firmware Upgrading
MIL-STD-810 C/D/E/F/G
IP54/55 Water & Dust Intrusion
PC Serial Interface
SDM Manual Input
Transparent Data Mode
1
1
DIGITAL – GENERAL
®
XDN
• N
• A
igital Air Interface
D
MBE+2
V
OCODER
6.25 & 12.5 kHz Channels
Over-the-Air Alias
ver-the-Air Programming
• O
Paging Call
mergency Call
• E
All Group Call
tatus Messaging
• S
Remote Stun/Kill
Remote Check
Short & Long Data Messages
GPS Location with Voice
1,2
1
1
1
1
NXDN®Scrambler Included
DIGITAL – CONVENTIONAL MODE
64 Radio Access Numbers (RAN)
Individual & Group Selective Call
Mixed FM/Digital Operation
Conventional IP Networks
Site Roaming
3
DIGITAL – TRUNKING MODE
Individual Private Call
Group Call & Broadcast Call
Telephone Interconnect
Transmission Trunked Mode
Message Trunked Mode
Call Queuing with Priority
Late Entry (UID & GID)
4 Priority Monitor ID’s
Remote Group Add
Failsoft Mode
4
4
4
4
4
1
MULTI-SITE IP NETWORKS COMPATIBLE
60,000 GIDs / UIDs
ide Area Group Call
W
Auto Roaming Registration
roup Registration
G
Single Zone / Multi-Zone / List Scan
Single Priority Scan (Conventional)
ANALOG MODES – GENERAL
12.5 & 25* kHz Channels
Conventional & LTR®Zones
FleetSync®/II, MDC-1200, DTMF
QT/DQT/Two-Tone (Conventional Zones Only)
Voice Inversion Scrambler (16 Codes)
3
FleetSync®/II
PTT ID ANI / Caller ID
Selective / Group Call
Emergency, Status & Text Messages
3
3
1
MDC-1200
PTT ID ANI / Caller ID
Emergency, Radio Check & Inhibit
3
3
Three Models Available: Basic Unit: No LCD, No Front Keys 8-Character LCD, 4 PF Keys 8-Character LCD, 4 PF Keys, 12-Key DTMF Keypad (Not Actual Size)
http://nexedge.kenwood.com
Options
KNB-55L
i-ion Battery Pack
L (1,480mAh)
KNB-56N
i-MH Battery Pack
N (1,400mAh)
KNB-57L
i-ion Battery Pack
L (2,000mAh)
KBP-5
attery Case
B
KSC-25
apid Charger
R
KSC-30
egular Charger
R for KNB-56N
KSC-256K
Six Unit Gang Charger
KNB 55L
KSC-25
KRA-22
HF Low Profile
V
elical Antenna
H
KRA-23
UHF Low Profile
elical Antenna
H
KRA-26
HF Helical Antenna
V
KRA-27
UHF Whip Antenna
MC-45
K
peaker Microphone
S
KMC-48GPS
PS Speaker
G
icrophone
M
KEP-2
arphone Kit for
E
MC-45 (2.5mm plug)
K
KHS-22
Head Set
KVC-3
egular Rate Vehicular
R
harger Adapter
C (for KSC-30)
KVC-4
Rapid Rate Vehicular Charger Adapter
for KSC-25)
(
KHS-7A
ightweight Single
L
uff Headset
M
KHS-8BL
-wire Palm Mic with
2 Earphone (Black)
KHS-9BL
-wire Lapel Mic
3
ith Earphone (Black)
w
LH-179
K
Leather Case
KLH-180
ylon Case
N
KVC-3
KBH-12
Belt Clip
Contact an authorized Kenwood dealer for details and complete list of all accessories and options.
All accessories and options may not be available in all markets.
Main Specifications
NX-220 NX-320
GENERAL
requency Range Type 1 136-174 MHz 450-520 MHz
F
Number of Channels w/LCD Model 260
Zones w/LCD Model 128
ax. Channels per Zone w/LCD Model 250
M
hannel Spacing Analog 12.5 / 15 / 25* / 30* kHz 12.5 / 25* kHz
C
Operating Voltage 7.5V DC ± 20%
attery Life 5-5-90 KNB-55L (1480) Approx.8.5 hours
B
Operating Temperature Range** Frequency Stability ± 2.0 ppm ± 1.0 ppm Antenna Impedance 50 Ω Dimensions (W x H x D)
Projections not included
Weight (net) with KNB-55L 10.76 oz (305 g)
FCC ID Type 1 ALH430900 ALH431000
IC Certification Type 1 282D-430900
ype 2 400-470 MHz
T
w/o LCD Model 64
w/o LCD Model 4
/o LCD Model 16
w
Digital 6.25 / 12.5 kHz 6.25 / 12.5 kHz
NB-56N (1400) Approx.8.5 hours
K KNB-57L (2000) Approx. 11.5 hours
with KNB-55L with KNB-56N with KNB-57L
with KNB-56N 14.29 oz (405 g) with KNB-57L 11.64 oz (330 g)
Type 2 ALH431001
Type 2 282D-431001
22˚ F to +140˚ F (
-
2.20 x 4.35 x 1.48 in (56 x 110.5 x 37.5 mm)
2.20 x 4.35 x 1.70 in (56 x 110.5 x 43.2 mm)
2.20 x 4.35 x 1.55 in (56 x 110.5x 39.5 mm)
-30˚ C to +60˚ C
Applicable MIL-STD & IP
)
RECEIVER
Sensitivity Digital @ 6.25 kHz (3% BER) 0.20 µV
Selectivity Analog @ 25 kHz 72 dB
Intermodulation Distortion Spurious Response Analog 70 dB
udio Distortion Less than 3%
A Audio Output 500 mW / 8 TRANSMITTER RF Power Output 5 W / 1 W Spurious Response 70 dB
M Hum & Noise Analog @ 25 kHz 45 dB
F
Audio Distortion Less than 3% Modulation 16K0F3E,* 11K0F3E, 8K30F1E,
Analog meas urements made per TIA/E IA 603 and specifi cations shown are typical . Specifications are s ubject to change without notice, due to advancements in technology..
* 25 kHz is not for sale in the USA and the US territories. ** Operating temp. range of the KNB-55L/57L : -10ºC to +60ºC
FleetSync®is a registered trademark of JVC KENWOOD Corporation.
®
LTR
is a registered trademark of Transcrypt International.
TM
AMBE+2
is a trademark of Digital Voice Systems Inc.
®
Windows
is a registered trademark of Microsoft Corporation.
®
is a registered trademark of JVC KENWOOD Corporation and Icom Inc.
NXDN
®
NEXEDGE
is a registered trademark of JVC KENWOOD Corporation.
igital @ 12.5 kHz (3% BER) 0.25 µV
D Analog (12 dB SINAD) 0.25 µV
nalog @ 12.5 kHz 65 dB
A Analog 70 dB
nalog @ 12.5 kHz 40 dB
A
MIL Standard MIL 810C MIL 810D MIL 810E MIL 810F MIL 810G
Methods/Procedures Methods/Procedures Methods/Procedures Methods/Procedures Methods/Procedures
Low Pressure 500.1/Procedure I 500.2/Procedure I, II 500.3/Procedure I, II 500.4/Procedure I, II 500.5/Procedure I, II High Temperature 501.1/Procedure I, II 501.2/Procedure I, II 501.3/Procedure I, II 501.4/Procedure I, II 501.5/Procedure I, II Low Temperature 502.1/Procedure I 502.2/Procedure I, II 502.3/Procedure I, II 502.4/Procedure I, II 502.5/Procedure I, II Temperature Shock 503.1/Procedure I 503.2/Procedure I 503.3/Procedure I 503.4/Procedure I, II 503.5/Procedure I Solar Radiation 505.1/Procedure I 505.2/Procedure I 505.3/Procedure I 505.4/Procedure I 505.5/Procedure I Rain 506.1/Procedure I, II 506.2/Procedure I, II 506.3/Procedure I, II 506.4/Procedure I, III 506.5/Procedure I, III Humidity 507.1/Procedure I, II 507.2/Procedure II, III 507.3/Procedure II, III 507.4 507.5/Procedure II Salt Fog 509.1/Procedure I 509.2/Procedure I 509.3/Procedure I 509.4 509.5 Dust 510.1/Procedure I 510.2/Procedure I 510.3/Procedure I 510.4/Procedure I, III 510.5/Procedure I Vibration 514.2/Procedure VIII, X 514.3/Procedure I 514.4/Procedure I 514.5/Procedure I 514.6/Procedure I Shock 516.2/Procedure I, II, V 516.3/Procedure I, IV 516.4/Procedure I, IV 516.5/Procedure I, IV 516.6/Procedure I, IV
International Protection Standard
Dust & Water Protection IP54/55
*To meet MIL810 and IP grade, the 2-pin connector has to be connected.
NX-220 NX-320
8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D
Footnotes from front:
1
Requires compatible PC software
application or console.
2
Non Display Model- Pre-programmed
key operation.
3
S Version- LCD dependent and some
key-based functions not available.
4
These trunked features are primarily system programming and operational dependent. Priority Monitor also requires NX subscriber settings.
KLH-179
Ω
ADS#56311 Printed in USA
Loading...