KRC-666/G/R
8
TEST MODE
1. How to enter the test mode
• While holding the Preset 1 and Preset 3 keys, reset the unit.
2. How to exit from the test mode
• Reset the unit, momentary power down, ACC OFF, power
OFF, and Panel detached.
• (Note) The test mode cannot terminated by Panel is fall
down.
3. Initial status in the test mode
• Sources : All OFF.
• Display : All segments are lit.
• Volume : -10 dB (displayed as 30)
• Loudness : OFF
•CRSC : OFF regardless of the presence of
switching function.
• SYSTEM Q : Flat.
• BEEP : When pressing any keys, the buzzer
generates a beep at any time.
•
DISPLAY TYPE
: TYPE A
4. RDS automatic measurement
• An addition to disposal of substitute for visual check PS
display as usual production lines.
• P-CON terminal is OFF by force, when received the PS
data and in case of corrobaration PS display is "RDS_TEST".
(“_” is mean blank.)
• This disposal is test mode only.
• P-CON is switching the source or return with power on → off.
5. Special display in Tuner mode
When any of the following messages is displayed in Tuner
mode, the front end may be abnormal.
• "TNE 2P NG": The EEPROM is set to the default (unsta-
ble values) because the F/E was shipped without passing
through the adjustment process, etc.
• "TNCON NG": Communication with the F/E is not possible.
6. Forced switching of K3I
•Each press of the Preset 6 key in Tuner mode should
switch K3I from AUTO → Forced Wide → Forced Middle
→ Forced Narrow → AUTO. The initial status is AUTO
and the display shows these modes as follows.
• AUTO : FMA
• Forced Wide : FMW
• Forced Middle : FMM
• Forced Narrow : FMN
7. Test mode specifications of the cassette
receiver
•BLANK SKIPP :OFF
8. Audio-related specifications
• A short press of the Q key initiates the audio adjustment
mode.
•Pressing the ❉ key on the remote initiates the audio
adjustment mode.
•Fader is selected to the initial item.
• Continuous holding of a remote control key is inhibited.
•Bass, Middle and Treble are adjusted in 3 steps of -8/0/+8
with the Track Up/Down keys.
•Balance is adjusted in 3 steps of L15/0/R15 with the Track
Up/Down keys.
•Fader is adjusted in 3 steps of F15/0/R15 with the Track
Up/Down keys.
•Volume Offset is adjusted in 2 steps of -8/0 with theTrack
Up/Down keys.
9. Menu-related specifications
• A short press of the MENU key initiates the Menu mode.
Except, tape source is usually press and hold 1 second to
enter the menu mode and short press initiates turn over.
• Pressing the DNPP/SBF key on the remote initiates the
Menu mode.
• Continuous holding of a remote control key is inhibited.
•Contrast is adjusted in 3 steps of 0/5/10(5x7dot), 0/4/7
(14seg) with the Track Up/Down keys.
10. Backup current measurement
• When the unit is reset while ACC is OFF (i.e. by turning
Back-Up ON), the MUTE terminal goes OFF in 2 seconds
in place of 15 second.