KDC-7080R/RY/RV/RYV
MICROCOMPUTER’S DESCRIPTION
System µ-com : UPD784217GC (X25-)
Terminal description
No. Pin name Function I/O Description Processing Operation
1 P120/RTP0 CHCON1 O Changer 1 control Active : Hi
2 P121/RTP1 CH_MUTE I Changer muting input MUTE Requested : Hi
3 P122/RTP2 REQH O Handshake request to changers Active : Lo
4 P123/RTP3 ILL_ON O Illumination output Active : Hi
5 P124/RTP4 NC O Open
6 P125/RTP5 CD_SW2 I 12cm DISC detection ON : Lo
7 P126/RTP6 CD_SW1 I Loading detection ON : Lo
8 P127/RTP7 NC O Open
9 Vdd Vdd - Positive power supply
10 X2 X2 - Main clock connection
11 X1 X1 - Main clock connection
12 Vss Vss - GND
13 XT2 XT2 - Sub clock connection
14 XT1 XT1 - Sub clock connection
15 RESET RESET I Reset input Active : Lo
16 P00/INTP0 CH_RST O Changer reset output Active : Lo
17 P01/INTP1 R_CLK I RDS clock input
18 P02/INTP2/NMI REQC I Handshake request from changer Active : Lo
19 P03/INTP3 N C I/O
20 P04/INTP4 N C I/O
21 P05/INTP5 N C I/O
22 P06/INTP6 SC_REQ I Handshake request from panel µ-com
23 AVdd AVdd - A/D analog power supply
24 AVref0 AVref - A/D reference voltage input
25 P10/ANI0 PHONE I PHONE detection terminal
26 P11/ANI1 SRM_SW1 I SRM position detection Open : Hi
27 P12/ANI2 NOISE I FM noise detection Analog input
28 P13/ANI3 SMETER I FM signal meter detection Analog input
29 P14/ANI4 IF_MODE I K2I IF selector Wide : Hi / Narrow : Lo
30 P15/ANI5 NC I GND
31 P16/ANI6 M_MUTE_R I Mute request from meshanism Mute requested : Lo
32 P17/ANI7 M_MUTE_L I Mute request from meshanism Mute requested : Lo
33 AVss AVss - A/D GND
34 P130/ANO0 EXT_AMP O EXT_AMP control
35 P131/ANO1 M_RST O Reset output to mechanism Reset : Lo
36 AVref1 - D/A reference voltage input
37 P70/RxD2/SI2 DATAC I Data line from changer
38 P71/TxD2/SO2 DATAH O Data line to changer
39 P72/ASCK2/SCK2 CH_CLK I/O Clock line from/to changer
40 P20/RxD1/SI1
41 P21/TxD1/SO1
42 P22/ASCK1/SCK1 L_CLK/MC_CLK I/O Clock line to LCD driver
43 P23/PCL M_STOP I/O Stop request to mechanism Stop Requested : Lo
44 P24/BUZ BEEP O Beep output Active : Hi
45 P25/SI0 PLL_CE O CE output to PLL
46 P26/SO0 PLL_DATA I/O Data in/out with PLL
47 P27/SCK0 PLL_CLK O Clock output to PLL
48 P80/A0 CD_SW3 I Switch detection ON : Hi
49 P81/A1 LO/EJ O Loading/Eject control Loading : Lo / Eject : Hi
L_DATAL/SC_DATA
L_DATAS/MC_DATA
I Data line from LCD driver
O Data line to LCD driver
1V or less : PHONE
2.5V or more : NAVI MUTE
3
KDC-7080R/RY/RV/RYV
MICROCOMPUTER’S DESCRIPTION
No. Pin name Function I/O Description Processing Operation
50 P82/A2 MOSW O Motor output Loading : Hi / Eject : Lo
51 P83/A3 MECH_DET I Mechanism detection ON : Hi / OFF : Lo
52 P84/A4 PAN 5V O Panel detection OFF : Hi
53 P85/A5 L_CE/P_RST O CE to LCD driver / Panel µ-com reset
54 P86/A6 L_INH/MC_REQ O Reset to LCD driver
55 P87/A7 DIM_CON O DIM control
56 P40/AD0 QUAL I RDS receiving condition Good : Hi
57 P41/AD1 R_DATA I RDS data input
58 P42/AD2 SRM_SUB– O SRM sub motor output
59 P43/AD3 SRM_SUB+ O SRM sub motor output
60 P44/AD4 SRM_DET I SRM mechanism detection ON : Lo / OFF : Hi
61 P45/AD5 SRM_SW2 I SRM eject detection
62 P46/AD6 FM_SD I FM SD input
63 P47/AD7 NC O Open
64 P50/A8 AFC O Noise detection time constant switching
65 P51/A9 - O
66 P52/A10 WIDE O K2I Wide output Active : Hi
67 P53/A11 NARROW I/O K2I Narrow output Active : Hi
68 P54/A12 AM+B O AM power supply Active : Hi
69 P55/A13 FM+B O FM power supply Active : Hi
70 P56/A14 NC O Open
71 P57A15 NC O Open
72 Vss - GND
73 P60/A16 TYPE0 I Destination type switch
74 P61/A17 TYPE1 I Destination type switch
75 P62/A18 TYPE2 I Destination type switch
76 P63/A19 ST_TYPE0 I IC2 Var. 3 destination type 0 Initial value : Lo
77 P64/RD ST_TYPE1 I IC2 Var. 3 destination type 1 Initial value : Lo
78 P65/WR NC O Open
79 P66/WAIT PRE MUTE R O Audio mute Active : Lo
80 P67/ASTB PRE MUTE L O Audio mute Active : Lo
81 Vdd - Positive power supply
82 P100/TI5/TO5 NC O Open
83 P101/TI6/TO6 SVR O Power IC reset Power ON : Lo
84 P102/TI7/TO7 NC O Open
85 P103/TI8/TO8 P_MUTE O Power IC muting Active : Lo
86 P30/TO0 ANT_CON O Antenna control Active : Hi
87 P31/TO1 IC2_SCK O IC2, IC5, EEPROM clock line
88 P32/TO2 DIMMER I Dimmer detection Active : Lo
89 P33/TI1 P_CON O Power control Active : Hi
90 P34/TI2 ACC_DET I ACC detection ACC OFF : Hi
91 P35/TI00 REMO I Remote control input
92 P36/TI01 P_ON O µ-com peripheral power supply Active : Hi
93 P37 BU_DET I Momentary power down detection
94 TEST Å\ - Test GND
95 P90 IC2_SDA I/O IC2, IC5, EEPROM data line
96 P91 MUTE O Muting output Active : Hi
97 P92 SW5 O 5V power supply Active : Lo
98 P93 MS_CL O CD mechanism clock line
99 P94 MS_DA I/O CD mechanism data line
100 P95 Å\ O
4
: Eject
↑
Station detected : Hi
Not detected : Lo
During reception : Hi
During search : Lo
Momentary power down : Hi
KDC-7080R/RY/RV/RYV
TEST MODE
1. Entering the test mode
Reset the unit by pressing the FM key and the Preset 6
key at the same time.
When the test mode is entered, all indicators light up.
2. Releasing the test mode
Reset the unit by pressing the preset 6 key.
Note: The unit cannot be reset by simply turning ACC
off, turning power off, or turning power off for a
brief moment.
3. Voltage adjustment on the FM S-meter
(1) Enter the test mode.
(2) While pressing the Preset 1 key, keep on pressing
the Preset 6 key.
(3) When the adjustment is made, "ADJ OK" is dis-
played. When adjustment cannot be made, "ADJ
NG" is displayed.
4. Writing SD voltage for the AM
(1) Enter the test mode.
(2) While pressing the Preset 1 key, keep on pressing
the Preset 6 key, which results in writing SD.
5. Forced switching of K2I Auto/Manual
In tuner-mode, keeping on pressing TI key , and the Auto
and Manual modes can be switched. The initial condition is in manual modes, which is indicated by flashing
DUAL dots.
6. Forced narrow/wide switching of K2I
In turner-mode, when Preset 6 is pressed, forced narrow/wide mode switching is made. The initial condition is in wide mode and the NEWS dot flashes.
7. CD receiver test mode specification
By pressing the track-up key, the unit jumps to the following tracks:
No. 9→No. 15→No. 10→No. 11→No. 12→No 13→No.
14→No. 9 (Goes back to the first position.)
When the track-down key is pressed, the unit jumps to
the previous track.
8. MD test mode specification
After loading MD, the unit plays No. 7. Then, the unit
jumps as follows each time it trackups.
No. 2→No. 13→No.23→No.30→
NO.34→No. 7 (Goes back to the first position.)
When the track-down key is pressed, the unit jumps to
the previous track.
9. Tape test mode
In the initial step, the blank skip is turned off.
10. Audio-related items
• The volume is -10dB (on display, it is 30).
• The loudness is off and CRSC is off regardless of functions.
• Buss/treble and balance/fader are to be adjusted by
the up/down key to full-boost/fullcut and fullfront/
fullrear respectively.
• The high-pass filter is adjusted by the up-key to
throughput/100Hz/200Hz and, by the down-key, to
200Hz/100Hz/throughput.
• Other adjustments are the same as before.
11. Backup current measurement
When reset in ACC-off condition (backup is on), the mute
terminal goes off after 2 seconds instead of 15 seconds,
when the ACC is turned off in the test mode. (In this
case, the panel/CD/C/MD mechanisms are not activated.)
12. Registering security code after changing E2PROM at
the services (Only for type M. However, RDS models
are excluded)
(1) Put the unit into the test mode (Refer to 1. Above
for how to enter the test mode.)
(2) Press SRC key to put the unit into the tuner mode.
(3) Press Audio key for one second and put the unit into
the menu mode.
(4) Press FM/AM key and then select "SECURITY."
(5) Press track up/down key for full 2 seconds.
(6) Press Preset 1, Preset 2, Preset 3, and Preset 4 and
then input codes.
Example: Inputting "3510."
• Press 1 key 4 times.
• Press 2 key 6 times.
• Press 3 key 2 times.
• Press 4 key once.
(7) Press DISP key for 3 seconds and confirm that
"APPRODVED" is displayed.
(8) Release the test mode. (Refer to "2. Releasing the
test mode" above.)
5
KDC-7080R/RY/RV/RYV
TEST MODE
13. Simplified method for clearing the security code
(Only for type K)
(1) When code is requested, continue pressing VOL UP
key for three seconds while pressing the DISP key.
(--- disappear.)
(2) Input "KCAR," using the remote controller (the same
as the 98 Model)
• Press Tenkey 5 twice and then press track-up key.
(Inputting "K")
• Press Tenkey 2 three times and then press trackup key. (Inputting "C")
• Press Tenkey 2 once and then press track-up key.
(Inputting "A")
• Press Tenkey 7 twice and then press track-up key.
(Inputting "R")
(3) Then, the security is released and the unit goes into
the Tuner Mode.
14. Writing MASK KEY on line
(1) While pressing the FM key and Preset 6 key, press
reset key to enter the test mode.
(2) Press AUDIO key for full one second to put the unit
into the menu mode.
(3) Select the "MASK KEY ," using the FM key or AM key .
(4) Press on the track up/down key to display "TRANS-
MIT 1."
(5) Point the MASK KEY to the light receptor and press
it for 0.5 second or longer.
(6) When "TRANSMIT 2" is displayed, press MASK KEY
for 0.5 second or longer. When this is conducted,
the counter codes for the first time and the second
time will not be compared.
(7) When "APPROVED" is displayed, writing is com-
pleted. time the demonstration mode is set and the
test mode is released.
Note: After an elapse of 30-minute period, during
which no code is written, an error is effected
and the device will power off.
15. Releasing MASK KEY requests (When reset or backup
is off when MASK KEY is approved)
(1) When power is turned on, "TRANSMIT 1" is dis-
played and the unit goes into MASK KEY request
mode.
(2) Point the MASK KEY to the light receptor and press
it for more than 3 seconds (until the level display
indicates full)
(3) When "TRANSMIT 2" is displayed, press the MASK
KEY again for more than three seconds. At this point,
when "TRANSMIT 1" is displayed, repeat the process in (2) above for the second time.
(4) When "APPROVED" is displayed, MASK KEY is ap-
proved and the unit turns power on.
(E2PROM in initial condition)
16. Initializing MASK KEY (returning to the default condition from MASK KEY approved state)
(1) While pressing the FM key and Preset 6 key at the
same time, press RESET to enter the test mode.
(2) "TRANSMIT 1" is displayed and the unit goes into
MASK KEY request mode. The display at this point
will be "**" instead of "[ ]".
(3) Use MASK KEY release remote controller for more
than three seconds.
(4) When "TRANSMIT 2" is displayed, press the MASK
KEY for more than three seconds for the second
time.
(5) When "APPROVED" is displayed, the MASK KEY is
released and the demonstration mode is set. Then,
the test mode is released, returning the unit into default condition.
17. Clearing from the MASK KEY
(1) While pressing FM key and Preset 6 key at the same
time, press RESET to enter the test mode.
(2) Press the AUDIO key for full one second to put the
unit into the menu mode.
(3) Select MASK KEY, using track up/down key.
(4) Press on the FM key or AM key for full two seconds
and the unit will display "TRANSMIT 1."
(5) Point the MASK KEY release controller to the light
receptor and press it for 3 seconds or longer. (Until
the level display indicates full.)
(6) When "TRANSMIT 2" is displayed, press MASK KEY
for 3 seconds or longer for the second time. If
"TRANSMIT 1" is displayed, start again from (5)
above.
(7) When "APPROVED" is displayed, E2PROM is cleared.
The unit goes back to the condition described in Line
14: Writing MASK KEY on line (E2PROM in initial
condition)
18. Other
• Automatic panel closing does not occur in case a
TAPE, CD, or MD is inserted.
•
Panel is opened/closed when A TT key is tur ned On/Off.
( A remote controller is used when turning ATT on.)
• The DNPP/SBF key of the remote controller (RC-510)
is used for tuning the menu mode On/Off.
• The OPEN/CLOSE key of the remote controller (RC-
510) is used for tuning the audio mode On/Off.
• The feed on the menu will be feeds only for neces-
sary features.
• "CODE OFF" and other displays will not be issued
when the power is turned on.
• The dimmer of the FL model and contrast on the LCD
model can be adjusted only for 0/5/10 by the UP/
DOWN key.
6