iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
if the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
WHAT TO DO iF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use any phone in your building.
* immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
* if you cannot reach your gas supplier, call the fire department.
installation and service must be performed by a qualified installer,
service agency or the gas supplier.
GcIs
30" rain
Appliances Installed in the
state of Massachusetts:
This Appliance can only
be installed in the state
of Massachusetts by a
Massachusetts licensed
plumber or gas fitter.
This appliance must be
installed with a three (3)
foot / 36 in. long flexible
gas connector. A "T"
handle type manual gas
valve must be installed in
the gas supply line to this
appliance.
Cutout Dimensions
Figure |
36" Gas Cookto 34 1,,_ 19 1/8 19 3,_
All dimensions are stated in inches and (cm).
Dimension H includesa 5" (12.7 cm) space underneath the cooktop for connection to gas supply line.
NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
Printed in United States
318201491 (1004) RevoA
English - pages 1-9
Espa_ol - p6ginas 10-18
Wiring Diagram 19-20
important Notes to the installer
1. Read all instructions contained in these
installation instructions before installing the
cooktop.
2. Remove all packing material before connecting
the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the
consumer,
.
Note: For operation at 2000 ft. elevations
above see level, appliance rating shall be
reduced by 4 percent for each additional
1000 ft.
Important Note fo the Consumer
Keep these instructions with your Use and Care
Guide for future reference.
iMPORTANT SAFETY
iNSTRUCTiONS
installation of this cooktop must conform with
local codes or, in the absence of local codes,
with the National Fuel Gas Code ANSI Z223.1/
NFPA 54 in the United States, or in Canada, with
the Canadian Fuel Gas Code, CAN/CGA B149
and CAN/CGA B149.2.
* When installed in a manufactured (mobile)
home installation must conform with the
Manufactured Home Construction and Safety
Standard, title 24 CFR, part 3280 [Formerly
the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD (part
280)] or, when such standard is not applicable,
the Standard for Manufactured Home
Installation, ANSI/NCSBCS A225.1 or with local
codes where applicable.
* Be sure your cooktop is installed and
grounded properly by a qualified installer or
service technician.
* This cooktop must be electrically grounded
in accordance with local codes or, in their
absence, with the National Electrical Code
ANSI/NFPA No. 70--latest edition in
the United States, or in Canada, with the
Canadian Electrical Code, CSA C22.1 Part 1.
" The burners can be lit manually during an
electrical power outage. To light a burner,
hold a lit match to the burner head, then
slowly turn the Surface Control knob to LITE.
Use caution when lighting burners manually.
* Do not store items of interest to children in
cabinets above the cooktop. Children could be
seriously burned climbing on the cooktop to
reach items.
* To eliminate the need to reach over the
surface burners, cabinet storage space above
the burners should be avoided.
" Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.
* Never use your cooktop for warming or
heating the room. Prolonged use of the
cooktop without adequate ventilation can be
hazardous.
* Do not store or use gasoline or other
flammable vapors and liquids near this or any
other appliance. Explosions or fires could result.
The electrical power to the cooktop
must be shut off while gas line connections are
being made. Failure to do so could result in
serious injury or death.
This cooktop has been design certified by CSA
International. As with any appliance using gas
and generating heat, there are certain safety
precautions you should follow. You will find them
in the Use and Care Guide, read it carefully.
13" (33 cm)
Max. Depth
For Cabinet
Installed
Above
Cooktop.
18" Min.
(45.7 cm)
\ .................
30" (76.2 cm) Min.
Clearance Between
the Top of the
Cooking Platform
and Unprotected
__detr Metal
Clearance
2" (5.1 cm) Minimum Distance
Between Rear Edge of Cutout
Nearest Combustible
Surface Above Countertop.
i
24" IV]in. 21/4'' (5.7 cmi Min.
(61 era) From Counter Edge to
X _ Front Edge of Cutout.
i i ..................
\ ........... - If a drawer is present underneath,
\_ allow at least 61/2'' (16.5 cm)
To eliminate the risk of
burns or fire from reaching over
heated surfaces, cabinet storage
space located above the cooktop
should be avoided. If cabinet
storage is provided, risk can be
reduced by installing a range hood
that projects horizontally a
minimum of 5" (12.7 cm) beyond the
bottom of the cabinets.
of clearance below the counter
top. Make sure there will be no
interference with gas or electrical
connection.
Never store flammable
products in the drawer.
30" Cooktop 30" (76.2cm) 7" (17.8cm) 7" (t7.8cm)
36"Cooktop 36" (91.4cm) 7" (17.8cm) 7" (17.8cm)
Figure 2 = CABINET DESIGN
3
Typical Under Counter Installation of an Electric Built-in Oven with a
Cooktop Mounted Above
All mounting hardware must
be used to secure the built-in
oven to the cabinets. Refer to
the built-in oven installation
instructions.
Junction box
must be located
approx. 3 *wto the
left of the built-in
oven cutout.
208/240 Volt
grounded junction
box for built-in oven.
Side filler panels are necessary
to isolate the unit from adjoining
This cooktop may be
installed over certain
built-in electric oven
models.
cabinets. Panel height should allow
for installation of approved cooktop
models. See "Typical Gas Cooktop
Installation Over an Electric Built-in
Oven Installed Under the Counter" on
next page.
36"
(91.4 cm) Min.
i
Cut an opening in wood base minimum 4"
(10.2 cm) x 4" (10.2 cm) to route armored
cable to junction box.
If no cooktop is
installed directly
over the oven
unit, 5" (12.7cm)
maximum is
allowed.
Use 3/4" (1.9 cm)
plywood, installed on
two runners, flush with
toe plate. Base must be
capable of supporting
Unit will
overlap
cutout
(minimum)
150 pounds (68 kg) for
27" models and 200
pounds (90 kg) for 30"
models.
edges by
1" (2.5cm)
4 1/2" (11.4 cm)
Max. _
30" (76.2) 27 _A" (69,2cm) 28_A'' (71.8) 28_A'' (72.4) 29" (73.7) 23_A'' (59.7)
27" (68.6) 27 _A" (69,2cm) 28_A'' (71.8) 247/?' (63.2) 25_A'' (64.1) 23_A'' (59.7)
Figure 3
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
FRONT VIEW
18"
14_---- (45.7 cm)
_ Max.
[
GAS COOl<TOP : i J
Approx.
..... 61/2 _ [
F_areUn_on" IJ< [
WALL OVEN CABINET %9
Cabinet sides or _ _:_r_o r
Manual Shutoff: Valve
(To be accessible
for shut-off valve
operation)
SIDE VIEW
........_ GAS COOl<TOP [
/ i
WALL OVEN : :
Figure 4
5
!
1. Wall Outlet Location
12" _1
,__.(30.58cm)
12_0.3cm)-I _-_
120V grounded outlet
on rear wall.
_Center line 22"
Of unit (55.9 cm)
, NOTE:If an outlet
't is not available, [
, haveone installed by |
'l aqualified technician.
10"
<25._,cm>
To clamp down, insert an angle bracket into the slot
on each side of the unit as shown. Run thumb screw
up through the bracket, up against the bottom of the
counter. Tighten until the unit draws down and is secure.
3. Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4"
of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation, the maximum inlet pressure to the
regulator must be no more than 14" of water column
(W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least !" (or 2.5 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
" " ._Center line
Of unit Figure 5
2. Cooktop Installation
1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout.
After inserting the cooktop into the countertop opening,
make sure the unit is sitting on the metal flange around
the top of the burner box. Cooktop must not sit on the
glass or the porcelain top. Avoid cutting an oversized
hole in the countertop.
NOTE: Do not use caulking compound; cooktop should
be removable for service when needed.
Granite countertop Installation Kit
A Granite Countertop Installation kit # 903103-9010 can
be ordered through a Sears Service Center.
Clamp Down Information
Once the cooktop is installed in the counter opening,
you must clamp the unit down as shown.
Seal
Coaktap _k
I
.._ Counferfop
The gas supply line to the range should be 1/2" or 3/4"
pipe.
4. LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LP gas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANE GAS
CONVERSION".
The conversion must be performed by a qualified
service technician in accordance with the kit instructions
and all local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Important: Remove all packing material and literature
from cooktop before connecting gas and electrical
supply to cooktop.
Angle ._
Brackef
Figure 6
Thumb
_ Screw