Kenmore Elite 72180809400, 72180802400, 72180803400, 72180804400 Installation Guide

Models/Modelos
721.80802
721.80803
721.80804
721.80809
INSTALLATIONINSTRUCTIONS INSTRUCCIONESDEINSTALACION
l
Read and save these installation instructions.
Lea y guarde estas instrucciones de
instalaciSn
E L I T E _rR>
MicrowaveHoodCombination
CombinacibnMicroondasCampana
Part No. 3828W5U0360 Sears, Roebuck and Co., Hoffman Estates, IL.60179 U.S.A www.sears.com.
YOUR SAFETY FIRST
BEFORE YOU START
Proper installation is the installer's responsibility!
- Read the entire manual before you begin.
- The model number label is located on the oven front. See Figure 1.
- Mounting plate is located on back side of microwave oven. See Figure 2.
BE SURE TO READ THE FOLLOWING SAFETY INSTRUCTIONS:
Model and Serial
Number Plate
Cooking Guide
±
Mounting plate (Remove fron oven to install.)
Back of oven
Figure 1 Figure 2
WARNING
FOR YOUR SAFETY:
You will need TWO people to install this oven. It is heavy and could cause personal injury if not handled properly. The dimensions of the oven are as follows:
Height : 16-7/16 inches Width : 29-15/16 inches
Depth : 15-3/8 inches Weight : 62 pounds
AVOID ELECTRICAL SHOCK!
- Before you drill into the wall, note where electrical outlets are and where electrical wires might be
concealed behind the wall. YOU COULD GET AN ELECTRIC SHOCK it you contact electrical wires with your drill bit.
- Locate and disconnect the power of any electrical circuits that could be affected by installing this oven.
IF YOU DO NOT DISCONNECT THE POWER, YOU COULD GET AN ELECTRIC SHOCK.
ELECTRICAL RATING OF THIS OVEN : 120V, 60Hz.
- You need a 120V, 60Hz, AC only, 20A, fused electrical supply (located in the cabinet above the microwave as close as possible to the microwave circuit) serving only the microwave.
YOUR SAFETY FIRST
THIS APPLIANCE MUST BE GROUNDED!
- If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape
wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
Place the plug into a properly installed and grounded outlet. See Figure 3.
Do not use an extension cord.
Keep the power cord dry and do net pinch or crush it.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG!
This appliance MUST be grounded!
_, WARNING _,
If you use the grounding plug improperly, you risk electric shock!
- Check with a qualified electrician if you are not sure whether the oven is properly grounded or if you do
not completely understand the grounding instructions. DO NOT USE A FUSE IN THE NEUTRAL OR GROUNDING CIRCUIT.
PROPERLY POLARIZED AND
GROUNDED OUTLET
Three-Pronged (Grounding) plug
Figure 3
_k WARNING _k
Improper grounding could result in electric shock or other personal injury.
SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR'S USE.
DO NOT EXPOSE YOURSELF TO EXCESSIVE MICROWAVE ENERGY!
- DO NOT try to operate the microwave oven with the door open.
- DO NOT tamper with or defeat the safety interlocks.
- DO NOT place objects between the microwave oven front face and the door.
- DO NOT allow soil or cleaner residue to build up on the flat surfaces around the microwave oven door.
- DO NOT operate the microwave oven if it is damaged.
- The microwave oven door must close properly to operate safely.
- DO NOT use the microwave oven:
If the door is bent.
If the hinges or latches are broken or loose.
If the door seals, sealing surfaces or glass is broken.
- DO NOT attempt to adjust or repair the oven yourself!
It should be adjusted and repaired by a qualified technician who can check for microwave leakage after repairing the oven.
_, WARNING _,
If you do not use the microwave oven as instructed, you could be exposed to excessive microwave energy.
:Z:
YOUR SAFETY FIRST
MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT.
- Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be
constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath.
- ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2" x 4" wall stud.
- DO NOT mount the microwave oven to an island or peninsula cabinet.
- BE SURE the upper cabinet and rear wall structures are able to support 150 Ibs., plus the weight of any items you place inside the oven or upper cabinet.
- Locate the oven away from strong draft areas, such as windows, doors, and strong heating vents.
- BE SURE you have enough space. See Figure 4 below for minimum vertical and horizontal clearance.
WARNING
If you do not mount the oven as instructed, you risk personal injury and/or
property damage.
-Grounded Plug (inside upper cabinet)
Power Supply
30"min.cabinetopeningwidth
30"min.clearancefrombottom ofcabinettocookingsurface or countertop
(Use templates included
with installation instructions)
Cord Hole
I
Figure 4
CAUTION
Before you begin installing the oven, PLACE A PIECE OF THE CARTON OR OTHER HEAVY MATERIAL (a blanket) over the countertop or cooktop to protect it. Do not use a plastic cover.
Failure to protect these surfaces could result inproperty damage.
PARTS, TOOLS, MATERIALS
THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN:
NOTE: Depending on your ventilation requirements, you may not use all of these parts.
Damper/duct connector
(for roof vented or wall vented installation) Not Actual Size
One power cord clamp bushing - Actual Size (for the cord hole in a metal upper cabinet)
Four 1/4" x 2" lag screws - Actual Size (for wall stud holes)
Two 114" x 3" bolts - Actual Size (for securing to the upper cabinet)
One power cord clamp and One dark-colored mountinc
(to hold the power cord)
Actual Size
Four 1/4" x 3" toggle bolts - Actual Size (for drywall holes)
Two tapping screws - Actual Size (for attaching the damper duct connector)
screw
Four spring toggle heads - Actual Size
(for the toggle belts)
NOTE: You need to install at least one lag screw into a 2" x 4" stud and four anchor bolts into the wall,
and the mounting area must meet the 150 Ibs. weight requirement.
One upper cabinet template - Not Actual Size
PARTS, TOOLS, MATERIALS
YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THE
INSTALLATION:
Carton or other heavy material for covering the counter top.
Clear tape (for taping the templates to the wall)
Saber saw (for cutting vent holes for roof or wall venting)
Phillips screwdriver (for the screws)
Pencil
Flat blade screwdriver (for the bolts)
Stud finder or thin nail.
Key hole saw (for the power cord hole)
3/8" and 3/4" wood drill bits ,_
1/2" and 3/16"
drill bits
Plumb line
Duct TapeMeasuring tape (metal preferred)
Small side cutters or tin snips
,,i
If you have brick or masonry walls, you need special hardware and tools.
The ductwork you need for the installation is not included. All wall and roof caps must have a back-draft damper.
Caulking gun
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS
_k WARNING _k
AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED!
1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail.
NOTE: The outlet should be on a circuit dedicated to the
microwave oven 120V, 60Hz., AC only, with a 20ampere fused electrical supply.
IMPORTANT: If you do not have the proper wall outlet,
you MUST have one installed by a qualified
electrician.
Upper I
Cabinet
-Grounded Outlet
2. You will cut the power-supply-cord hole (shown in Figure 4 Detail) later when you prepare the wall and upper cabinet in Step 4.
NOTE: Do not use an extension cord.
Keep the power cord dry and do not pinch or crush it.
Power-Supply-CordHole
Figure 4 Detail
_, WARNING _,
Improper grounding could result in electric shock or other personal injury.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY
CORD GROUNDING PRONG!
This appliance MUST be grounded!
STEP 2: PREPARE THE VENTING SYSTEM
NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork
fittings and length are shown in Figure 9, page 9.
WARNING - FIRE HAZARD A
I THIS OVEN MUST BE PROPERLY VENTED!
You may vent your oven in one of three ways:
Roof Venting If your oven is located on an outside wall near the roof, as in Figure 6 (3-1/4" x 10" duct) and
Figure 8 (6" round duct.)
Wall Venting If your oven is located on an outside wall on the first floor of your house, as in
Figure 5 (3-1/4" x 10" duct) and Figure 8 (6" round duct.)
Room Venting If your oven is located on an inside wall of your house, as in Figure 7.
NOTE: If you choose the rear exhaust method (roof or wall venting), be sure there is enough clearance within the
wall for the exhaust duct.
cabinet
Wall Venting
cabinet_ _
wall cap
Roof Venting
_ roof cap
3-1/4"x10" duct
/1
Wall venting
3-1/4"x10" through-the-wall duct
o
Roof ventin_
through-the-roof
I
Figure 5
REMEMBER AS YOU INSTALL THE VENTING:
Keep the length of the ductwork and the number of elbows to a minimum to
ventilate your oven efficiently. See examples on page 9.
Keep the size of the ductwork the same.
Do not install two elbows together.
Use duct tape to seal all joints in the duct
system.
Use caulking to seal the exterior wall or roof opening around the cap.
cabinet
ov_
Room Venting
Figure 7
Figure 6
roof cap
6" min. diameter
elbow
3-1/4"to round ducttransition
wall cap
3-1/4"toround ductworktransition
Figure 8
STEP 2: PREPARE THE VENTING SYSTEM
STANDARD FITTINGS
NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension
duct installed between the damper assembly and the adapter to prevent the exhaust damper sticking.
DUCT LENGTH
The total length of the duct system, including straight duct, elbows, transitions, wall or roof caps must not exceed the equivalent of 140 feet.
For best performance, do not use more than three 90 degree elbows. Below are the standard fittings and their equivalent length in feet.
3-1/4"x10" to 6" = 5ft.
90° elbow = 1Oft.
3-1/4"x10" roof cap = 24ft.
3-1/4"x10" wall cap = 40ft.
45 ° elbow = 5ft. 3-1/4"x10" fiat elbow
3-1/4"x10" 90° elbow = 25ft.
Figure 9
To calculate the equivalent length of each duct piece used, see the examples below.
Exam )les
For 3-1/4"x10" SYSTEMS
3_1/4"x10" _ 6ft. _ wall cap
90 ° elbow *_fr! I 0_ b"
For 6" ROUND SYSTEMS
90°elbows _---- 6ft. -_/wall cap
transi_
1 transition = 5 ft.
1 3-1/4" x 10" 90° elbow = 25ft. 1 wall cap = 40 ft.
8 feet straight duct = 8 ft. TOTAL LENGTH = 73 ft.
2 90 °elbows = 20 ft. 1 wall cap = 40 ft.
8 feet straight = 8 ft. TOTAL LENGTH = 73 ft.
= 1Oft.
STEP 3: PREPARE THE VENTING BLOWER
Your microwave oven is shipped with the blower assembled for room venting (recirculating). You need to adjust the blower if you want wall vented or roof vented installation.
WARNING A
ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT.
DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result
in electrical shock.
REMOVE THE MOUNTING PLATE:
1. Remove any shipping materials and parts from inside the microwave oven.
2. Cover the counter top or cooktop with a thick, protective covering to protect it from damage and dirt.
See Figure 10.
NOTE: If you have a free-standing range, disconnect
it, move it onto a piece of cardboard or hardboard and pull it away from the wall, so
that you can get closer to the upper cabinet and back wall for easier measuring and
drilling.
3. Remove mounting plate 2 screws from the mounting plate as shown and discard them. (See Figure 11.)
4. The mounting plate will also be used to locate and mark the mounting holes on the rear wall.
5. Locate exhaust adaptor, grease filters and hardware packet.
6. At this point, remove any adhesive tape (if there is
any), on the exhaust adaptor, the grease filters and the power supply cord.
Figure 10
I il II:il pM°t_enting
_--- Control panel side
A thicK, protective
covenllg
ROOM VENTED INSTALLATION:
Go to STEP 4, PREPARE THE WALL AND UPPER
CABINET FOR INSTALLATION located on page 13.
10
Figure 11
STEP 3:
PREPARE THE VENTING BLOWER
WALL VENTED INSTALLATION:
1. Remove two blower unit mounting screws and one blower plate screw. Remove the blower plate from
cabinet. See Figure 12.
2. Carefully lift the blower unit out of the microwave oven. Disconnect the blower wire from connector.
See Figure 13.
3. Use side cutters or tin snips to cut and remove knockouts "B" from Back plate. Discard knockouts.
Be careful not to distort the plate. See Figure 14.
4. Rotate the unit so that the exhaust ports face the rear of the cabinet. See Figure 15. Before you insert blower unit, blower wire must be like Figure 15.
5. Reassemble the blower wire into the connector.
6. Place blower unit back into cabinet. Check that the exhaust ports face towards the rear of the cabinet.
See Figure 16.
7. Reattach the blower plate to the top of the cabinet as it was originally assembled. Attach with one blower
unit mounting screw and then one blower plate mounting screw. See Figure 17. NOTE: When using wall venting,you need one
blower unit mounting screw.See Figure 17.
8. Go to STEP 4, PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION located on page 13.
blower unit
Knockouts "B"
connector
/
blower plate
Figure 12
Figure 13
back plate
_late
mounting screw
blower unit mounting screw
blower wire
=
Parts "B"
Figure 14
exhaust
ports
Figure 16
Knockouts Parts "B"
blower unit
Figure 15
_ lower plate
blower unit _
mounting
screw
exhaust
blower unit mounting screw
Figure 17
11
STEP 3: PREPARE THE VENTING BLOWER
ROOF VENTED INSTALLATION:
1.
Remove two blower unit mounting screws and one blower plate screw. Remove the blower plate from cabinet. See Figure 18.
2.
Carefully lift the blower unit out of the microwave
oven.
3.
Rotate blower unit 90 ° so the exhaust ports face the top of the cabinet. See Figure 19.
4.
Place blower unit back into microwave oven.
5.
Use side cutters or tin snips to cut and remove knockouts "A" from blower plate. Discard knockouts.
Be careful not to distort the plate. See Figure 20.
6.
Reattach blower plate to microwave oven. Attach with the one blower unit mounting screw and then the one
blower plate mounting screw. See Figure 21.
NOTE: When using Roof venting,you need one
blower unit mounting screw.See Figure 21.
_ lower plate
blower plate
Figure 18
mounting screw
blower unit mounting screw
blower unit
blower unit
Figure 19
Knockouts "A"
blower plate
Figure 20
blower plate mounting
screw
blower unit mounting screw
Figure 21
12
Loading...
+ 25 hidden pages