(For Converting Free Standing Ranges from Natural Gas to Liquefied Petroleum Gas)
(For Models with 1 Small, 2 Medium and 1 Large Sealed Top Burners)
How to Convert the Range for use
with LP/Propane Gas
1. Convert the Pressure Regulator
To access the regulator, remove the warmer drawer.
a. _ Electrical Shock Hazard can occur and
result in serious injury or death. Disconnect electrical
power to the range before removing the warmer
drawer for servicing.
b. Open the drawer to the fully opened position.
c. Locate glide lever on each side of drawer, pull up on the
left glide lever and push down on the right glide lever
(see illustration).
d. Pull the drawer away from the range.
pull upwith E_er
%
I []
[]
Push down with finger
Remove
Regulato
Front Access Access
to Regulator:Remove Cover
e.
PressureRegulator
P
Remove the regulator access cover. Do not remove the
Pressure Regulator or allow it to turn.
f. Remove the dust protector from the cap. Using a 5/8"
wrench, unscrew the cap from the pressure regulator.
Do not remove the spring from the regulator•
g. Turn the cap over so the hollow end faces outward.
Place the solid end of the cap into the loop end of the
dust protector as shown in illustration below.
h. Replace the cap on the regulator. The letters LPshould
be visible on the exposed end of the cap. Snap the dust
protector over the regulator cap.
Dust
Protector
Spring _
. Cap
Hollow End Solid End
Towards Towards
Regulator Regulator
for Natural Gas for LP/Propane Gas
2. Convert Surface Burners for use with LP!
Propane Gas
Unlikethe standard gas range, THIS COOKTOP
IS NOT REMOVABLE. Do not attempt to remove this
cooktop.
Save the red natural gas orifices removed from the appliance
for possible future conversions to natural gas.
For large burner 10,000 BTU*: (Right front burner)
a. Remove the top grate and burner cap.
b. Remove the natural gas orifice from the center of
the burners using a 7 mm nutdriver.
c. Replace orifice in large burner with supplied
LP/Propane gas 1.00 mm green orifice. Tighten
orifice until snug. Use caution not to overtighten.
d. Remove screw "A". Insert large choke with smaller
inside diameter up and cutout down, as shown.
Replace screw"A". Be sure screw head is in line with
recess on choke.
For medium burners 7,500 BTU*: (Left front and left rear
burner)
a. Remove the top grate and burner cap.
b. Remove the natural gas orifice from the center of
the burners using a 7 mm nutdriver.
c. Replace orifice in medium burner with supplied
LP/Propane gas 0.89 mm brass orifice. Tighten
orifices until snug. Use caution not to overtighten.
d. Remove screw"A". Insert small choke with flat side
down. Replace screw "A". Be sure screw head is in
line with recess on choke.
e. Insert LPIPropane restrictor in cavity directly opposite
from the electrode. Curved side facing center of
burner. Tighten restrictor securely in place using
screw "B" supplied. Do not overtighten screw.
*For operation at elevations above 2000 ft., appliance
rating shall be reduced at the rate of 4 percent for each
1000 ft. above sea level.
2