Kenmore 153339960, 153339760, 153339560, 153339511HA, 153339460 Owner’s Manual

...
Owner's Manual
POWER MISER TM9
GAS WATER HEATER
FOR POTABLE WATER HEATING ONLY,
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN MOBILE HOMES.
MODEL NO.
153.339210 HA
153.339410 HA
153.339511 HA
40 Gallon Short High Altitude 40 Gallon Short
30 Gallon 40 Gallon High Altitude
40 Gallon 50 Gallon High Altitude
50 Gallon 50 Gallon High Recovery
40 Gallon (L.P.)
i iiil
ii: iiili
l i:i ii!i!!!
....
Safety Instruction
Installation
Operation
Care and Maintenance
Troubleshooting
Parts List
For Your Safety
AN ODORANT ISADDEDTOTHE GASUSED BYTHIS WATER HEATER.
i
i _iiiiiiiii!!iiiii_!i_ili:_iiiii!iiiiiiii
!
i i_i_!i!iii!i:ili:!;);::iii::!:!i:i_;::!jii
x i
!
C3 Technology TM Gas Water Heaters meet
the new ANSI Z21,10,1 standard that deals with the accidental or unintended ignition
of flammable vapors, such as those emitted by gasoline.
Read and understand instruction manuai and safety messages
before installing, operating or servicing this water heater
Failure to fallow instructionsand safety messages could result in
death or serious injury Instruction manua! must remain
with water heater
Sino puedeleer o entender elingles y necesita elmanual instructivo
y/o etiquetas en esparlol puede obtenerlos Ilamando al
1-800-821-2017. NO TRATE DE ]NSTALAR O OPERAR ESTE
CALENTADORDEAGUAsi noenflendelainformaciOnen lasetiquetas oen elmanual instructivo. No hacer casode esta advertencia podrla
resultaren laMUERTEO GRAVESLESIONESCORPORALES.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
--Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS:
o Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building.
-Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
= if you cannot reach your gas supplier,
call the fire department,
--Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A
PRINTED IN THE USA 0703 www.sears.com SUPERSEDES PART NO 184256-000
PART NO 184483-000
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very
important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
to potential personal injury hazards. Obey all safety This is the safety alert symbol. It is used to alert you
messages that follow this symbol to avoid possible
injury or death.
DANGER indicates an imminently
hazardous situation which, if not avoided, could result in death or injury.
WARNING indicates a potentially hazardous
situation which, if notavoided, could result
in death or injury.
situation which, if not avoided, may result
CAUTION indicates apotentially hazardous in minor or moderate injury.
CAUTION used without the safety alert
symbol indicates a potentially hazardous
situation which, if notavoided, could result
-- in property damage.
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.
IMPORTANT DEFINITIONS
Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.
© Sears, Roebuck and Co.
2
Read and understand instruction manual and safety messages
before installing, operating or servicing this water heater
Failure to follow instructions and safety messages could result in
death or serious Injury blstruction manual must [emain
with water heater
Water temperature over 125°F
(52°C) can cause severe burns instantly result ng in severe injury
or death. Children, the elderly, and the
physically or mentalJy dJsabted are at highest riskfor scald injury.
Feel water before bathing or
showering.
Temperature limiting valves are
available
Read instruction manual for safe
temperature setting
_LJ_ Fire Hazard
_,_, For continued protection against
risk of fire;
_., ,Do not install water heater on
W _v I carpeted floor.
_ ,Do not operate water heater if
, _ j flood damaged
Explosion Hazard
Overheated water can cause water tank explosion
Properly sized tempeature end pressure relief valve must
be installed in opening provided
Fire or Explosion Hazard
- Do not store or use gasoline or other flammable vapors and liquids n the vicinity of this or any other
appliance
Avoid all ignition sources if you smell LP gas.
Do not expose water heater control to excessive gas pressure
Use only gas shown on rating plate.
Maintain required clearances to combustibles
Keep ignition sources away from faucets after
Read instruction manual before
,- extended period of non-use.
installing, using or servicing
water heater
Improper installation and use may result
in property damage.
Do not operate water heater if flood damaged.
Inspect and replace anode
Install in location with drainage.
Fill tank with water before operat on
Be alert for thermal expansion Refer to instruction manual for installation and service.
Breathing Hazard - Carbon Monoxide Gas
install vent system in accordance with codes
Do not operate water heater if flood damaged
High altitude orifice mustbe installed for operation above 3,300 feet (1,006 m) (or above 5500 (I ,676 m) feet for high altitude models)
, ; ° Do not operateifsoot buildup.
Do not obstruct water heater air intake
O
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual
° Do not place chemical vapor emitting
with insulating jacket.
products near water heater
° Gas and carbon monoxide detectors
are availa b/e
3
ThankYou for purchasing a Kenmore water heater. Propedy
installed and maintained, it should give you years of trouble
free service. If you should decide that you want the new water
heater professionally installed by Sears call 1-800-4-MY-HOME ®. They will arrange for prompt, quality installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual:
CSA - Canadian Standards Association ANSI - American National Standards Institute
NFPA- National Fire Protection Association ASME - American Society of Mechanical Engineers
GAMA - Gas Appliance Manufacturers Association
This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 CSA 4.1 (current edition).
Read the "Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must . read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following: In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley
Rd, Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from possible carbon monoxide poisoning and fires. See
figure 1.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual. For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00. Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
RECOVERY MINIMUM DIMENSIONS
TANK TYPE RATEGALS. VENTPIPE DIAMETER IN INCHES(mm)
CAPACITY OF B'DJ PERHOUR INCHES INCHES HEIGHTTO
MODELNUMBER IN GALS(LTRS) GAS RATE @90°F RISE (mm) (mm) JACKET TOP
153.339210 HA 40 (151) NATURAL 40,000 40.9 3"(76) or 4" (102) 20 1/4" (514) 47 1/4" (1,200)
153.339260 40 (151) NATURAL 40,000 40.9 3"(76) or 4" (102) 20 1/4 "(514) 47 1/4" (1,200)
153.339360 30 (114) NATURAL 40,000 40.9 3" (76) or 4" (102) 15 3/4" (400) 57 1/2" (1,461)
153.339410 HA 40 (151) NATURAL 40,000 40.9 3" (76) or 4" (102) 18 1/4" (464) 55 1/2" (1,410)
153.339460 40 (151) NATURAL 40,000 40.9 3" (76) or 4" (102) 18 1/4" (464) 55 1/2" (1,410)
153.339511 HA 50 (189) NATURAL 40,000 40.9 3" (76) or 4" (102) 20 1/4" (514) 56 1/2" (1,435)
153.339560 50 (189) NATURAL 40,000 40.9 3" (76) or 4" (102) 20 1/4" (514) 56 1/2" (1,435)
153.339760 50 (189) NATURAL 52,500 53.7 4" (102) 20 1/4" (514) 56 1/4" (1,429)
153.339960 40 (151) PROPANE 37,000 37.8 3" (76) or 4" (102) 18 1/4" (464) 55 1/2" (1,410)
Materials Needed
To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these material, depending on your type of installation.
WATER HEATER tl__.l_<_ ,,,,_
IBSTA T,O. .......
KIT WITH FLEXIBLE _,;_, I CONNECTORS i!¸_ _!: ! FOR 3/4" (10.05 ram) OR 112" (12.7 ram)
THREADEDOR COPPER PLUMBING
i_ J,_N_ _T_ _r_ WATER HEATER HEAT
I I HEAT LOSS DUE TO
TRAPS HELP REDUCE
FLEXIBLE WATER HEATER GAS CONNECTOR WITH FITTINGS
DRAIN PANS AVAILABLE IN 20" (508 mm) DIAMETER FOR WATER HEATERS
HAVING A DIAMETER t8" (457 ram) OR LESS, 24" (6t6mm) DIAMETER FOR
WATER HEATERS HAVING A DIAMETER 22" (559 mm) OR LESSAND AVAILABLE IN 28" (7tl ram) DIAMETER FOR WATER
HEATERS HAVING A DIAMETER 26" (660 mm) OR LESS
EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS
(7.6 LITERS) AND 6 GALLONS (t8.9 LITERS) CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER
Basic Tools
You may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local
Sears Store.
Pipe Wrenches (2) 14" (356 mm) ;_ Screwdriver
Tin Snips
6' (1.82 m) Tape or Folding Ruler Garden Hose
Drill Pipe Dope or Teflon Tape DRILL
SLOT-HEAD SCREWDRIVER
TIN SNIPS
PHILLIPS SCREWDRIVER
ROLL OF TEFLON
TAPE (USE ONLY OH
WATER HEATER
CONNECTIONS)
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WATER AND GAS
CONNECTIONS
Additional Tools Needed When Sweat Soldering
Tubing Cutters or Hacksaw
Propane Tank
Soft Solder Solder Flux
Emery Cloth
Wire Brushes
TUBING CUTTER
HACKSAW
3/4" (19 mm) WIRE BRUSH
PROPANE
TORCH
ROLL OF
EMERY CLOTH
GARDEN HOSE 6 FOOT TAPE PIPE WRENCH
t/2" (t3 mm) WINE BRUSH
ROLL OF LEAD*FREE
SOFT SOLDER
SOLDER
FLUX
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe B Drafthood
C Anode D Hot Water Outlet
E Outlet F FlexibleWaterConnections
G Gas Supply H ManuaIGas Shut-off Valve I Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TOVENTTERMINATION
ON ROOF
A
J Drip Leg (Sediment Trap) S Flue Baffle
K Inner Door T Thermostat L Outer door U Drain Valve
M Union V Pilotand Main Burner N Inlet Water Shut-off Valve W Flue
O Cold Water Inlet X Drain Pan
P Inlet DipTube Y Thermostat Shield (optional)
Q Temperature-Pressure Relief Valve Z Piezolgnitor
R Rating Plate AA Air Intake Screen
INSTALL THERMAL EXPANSION
TANK IF WATER HEATER
IS INSIALLED IN A CLOSED
WATER SYSTEM
(T) THERMOSTAT
GAS CONTROL KNOB
WATER TEMPERATURE
(ADJUSTING DIAL)
/
x
AA
*ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
Q
"OFF .... PILOT .... ON" i
POSITION POSITION POSITION i
_TOP VIEW
(V) PILOT & MAIN BURNER
BURNER TUBE
W
Y
_'J MAIN BURNER
TH ER_COU PLEs_-x_ _
PILOT TUBING / "PILOT BURNER
THERMOCOUPLE
TGO
FIGURE1.
7
Removing the Old Water Heater
(_ Attach a hose to the water heater
drain valve and put the other end in a floor drain or outdoors. Open
the water heater drain valve. Open
a nearby hot water faucet which will relieve pressure in the water
heater and speed draining. The
water passing out of the drain valve
may be extremely hot. To avoid being scalded, make sure all
connections are tight and that the
water flow is directed away from
any person, see Figures 2 and 5.
FIGURE5.
FIGURE2.
(_) Turn the gas supply to the
(_) Turn "OFF" the water supply to the
(_ Check again to make sure the gas supply is to the
"OFF"
water heater.
If the main gas line shutoff valve serving all gas appliances is used, also shut "OFF" the gas at
each appliance. Leave all gas appliances shut "OFF" until the
water heater installation is
completed, see Figures 2 and 3.
water heater at the water shut off
valve or water meter. Some installations require that the water
be turned off to the entire house, see Figures 2 and 4.
water heater. Then disconnect the gas supply connection from the gas control valve.
FIGURE&
FIGURE&
"OFF"
(_Disconnect the vent from the draft hood where it connects
to the water heater. In most installations the vent pipe can
be lifted off after any screw or other attached devices are removed. Dispose of the draft hood. The new water heater
has a draft hood which must be used for proper operation.
If have to the water the twoyou
water pipes can be cut with a hacksaw approximately four
inches away from where they connect to the water heater,
see Figure 6. This will avoid cutting off pipes too short. Additional cuts can be made later if necessary, Disconnect the temperature-pressure relief valve drain line. When the
water heater is drained, disconnect the hose from the drain
valve. Close the drain valve. The water heater is now
completely disconnected and ready to be removed.
If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each
line. Also disconnect the piping remaining to the water heater,
see Figure 7. These pieces should be saved since they may
be needed when reconnecting the new water heater.
Disconnect the temperature-pressure relief valve drain line.
When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is
now completely disconnected and ready to be removed.
Mineral buildup or sediment may have accumulated in the
old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could
cause staining.
copper piping heater, copper
pipe
FIGURE&
Burn hazard
- Hot water discharge.
, Keep hands clear of drain
valve discharge,
FIGURE7.
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for
the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed:
Select a location indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system
as possible. Selected location must provide adequate clearances for
servicing and proper operation of the water heater.
Property Damage Hazard
heater's pilot light or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area.
Even though this water heater is a flammable vapors ignition resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other
flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.
Fire Hazard
For continued protection against riskof fire:
,Do not instalJ water heater on
carpeted flooc
.Do not operate water heater if
flood damaged.
AIIwater heaters eventually leak
Do notinstall without adequate drainage
Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow
will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must
have a minimum length and width of at least 2 inches (51 mm) greater that the water heater dimensions and must be piped to
an adequate drain. The pan must not restrict combustion air flow.
Fire or ExpJosion Hazard
" Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other app))ance
Avod all ignition sources if you smell LP gas.
* Donot expose water heater controi to excessive gas
pressure
. Use only gas shown on rating pJate. . Maintain required clearances to combustibles
. Keep ignition sources away from faucets after
,. extended period of non use
Read instruction manual before
_ installing, using or servicing ._,d(
_' water heater
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or
butane, etc.] and other substances such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water
This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may
result in a fire hazard.
Fire or Explosion Hazard
using or servicing water heater.
Improper use may result in fire or explosion
Maintan required clearances to combustibles.
Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 ram) from the vent
pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension
may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater.
TOP ViEW TOP VIEW
OF CLOSET OF CLOSET
WITHOUT DOOR WITH DOOR
(}" MIN O"MIN.
O" I_IN, 4" MIN,
S" MIN,
FIGURE8.
9
Breathing Hazard - Carbon Monoxide Gas
Install water heater in accordance
with the instruction manual and
NFPA 54.
Energy Conservation Act standards with respect to insulation
and standby loss requirements, making an insulation blanket
unnecessary.
Breathing Hazard - Carbon Monoxide Gas
To avoid injury, combustion and ventilation air must be taken from
outdoors.
S
Do not place chemical vapor
emitting products near water
heater.
Breathingcarbon monoxidecancause brain damageor
death. Always read andunderstandinstructionmanual
A gas water heater cannot operate properly without the correct amount of air for combustion, see Figure 9. Do not install in a
confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. Ifyou have any doubts or questions at
all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause
death, serious bodily injury, or property damage.
12" MAX. (305rnrn)
VENTILATION
AIR
OPENING O
AIRDUCT
FRONTVIEW _ (305ram)
OFDOOR
FIGURE9.
If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation air be taken from outside these areas.
.... . ?f_'v Do not obstruct water heater air
q':s. intake with insulating blanket.
i_i ','_i" Gas and carbon monoxide
detectors are available,
_ _ lni_thal_-Wltne.rthe(?_erinmaCCa°_dance
Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual
_i& WARNING
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions (See Figure 1 for
identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious
personal injury or death.
Do not apply insulation to the top of the water heater, as this
will interfere with safe operation of the draft hood.
Do not cover the outer door, thermostat or temperature & pressure relief valve.
Do not allow insulation to come within 2" (50.8 mm) of the
floor to prevent blockage of combustion air flow to the burner.
Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
Do obtain new warning and instruction labels from Sears
for placement on the blanket directly over the existing labels.
Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.
Combustion Air and Ventilation for Appliances Located in Unconfined Spaces
Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in
addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.
Insulation Blankets
Insulation blankets available to the general public for external
use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters, Your Kenmore water heater meets or exceeds the National Appliance
UNCONFINED SPACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with
doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue
gases. However, in buildings of tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier, etc.), additional air may need to be provided using the methods
described in Combustion Air and Ventilation for Appliances
Located in Confined Spaces.
10
Loading...