40 Gal. High Altitude
40 Gal.
50 Gal. High Altitude
50 Gal.
75 Gal. High Altitude
75 Gal
POWER MISERY 12
GAS WATER HEATER
• Safety Instructions
• Installation
• Operation
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED BY THIS
WATER HEATER
• Care and Maintenance
• Troubleshooting
• Parts List
Caution:
Read and Follow
All Safety Rules and
Operating Instructions
Before First Use of
This Product.
WARNING: If the information in these instructions are not fol
lowed exactly, a fire or explosion may result, causing property
damage, personal injury or death.
-Do not store or use gasoline or other flammable vapors and liq
uids in the vicinity of this or any other appliance.
-WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
buildinr
• Immediately call your §as supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you can not reach your gas supplier, call the fire department.
-Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
A WARNING
Improper installation, adjustment, alteration, service or maintenance
can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAM
AGE. Refer to this manual for assistance or consult the local Sears
Service Center or gas utility for further information.
A WARNING
Flammable vapors may be drawn by air currents from other areas
of the structure to this appliance.
Save this Manual for Future Reference.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
A WARNING
READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE
COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING
OR OPERATING THIS WATER HEATER.
Safety Precautions
▲WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE. Refer to this manu
al for assistance or consult your local Sears Service
Center for further information.
▲WARNING
WATER HEATERS EQUIPPED FOR ONE TYPE GAS
ONLY: This water heater is equipped for one type gas
only. Check the model rating plate near the gas control
valve for the correct gas. DO NOT USE THIS WATER
HEATER WITH ANY GAS OTHER THAN THE ONE
SHOWN ON THE MODEL RATING PLATE. Failure to
use the correct gas can cause problems which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. If you have any questions or doubts consult
your gas supplier or local utility.
_______________▲WARNING_______________
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ
UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR
STORED (GARAGES, STORAGE, AND UTILITY AREAS,
ETC): Flammable liquids (such as gasoline, solvents,
propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious burns to anyone in the area, as well as
property damage.
if installation in such areas is your only option, then the
installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of
flammable vapors from a floor spill being ignited, gasoline
and other flammable substances should never be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.
^
______________
if this water heater will be used in beauty shops, barber
shops, cleaning establishments, or seif-service laundries
with dry cleaning equipment, it is imperative that the
water heater or water heaters be installed so that com
bustion and ventilation air be taken from outside these
areas. Refer to the “Facts to Consider About the
Location” section of this manual and also the latest edi
tion of the National Fuel Gas Code, ANSI Z223.I, also
referred to as NFPA 54 for specifics provided concerning
air required.
▲WARNING
_______________
▲WARNING
A fire can start if combustible materials such as clothing,
cleaning materials, or flammable liquids are placed against
or next to the water heater.
▲WARNING
At the time of manufacture this water heater was provid
ed with a combination temperature-pressures relief valve
certified by a nationally recognized testing laboratory
that maintains periodic inspection of production of listed
equipment or materials, as meeting the requirements for
Relief Valves and Automatic Gas Shutoff Devices for Hot
Water Supply Systems, and the latest edition of ANSI
Z2I.22 and the code requirements of ASME, if replaced,
the valve must meet the requirements of local codes, but
not less than a combination temperature and pressure
relief valve certified as meeting the requirements for
Relief Valves and Automatic Gas Shutoff Devices for Hot
Water Supply Systems, ANSI Z2I.22 by a nationally rec
ognized testing laboratory that maintains periodic
inspection of production of listed equipment or
materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure
of the water heater (ISO Ibs./sq. in.) and a discharge
capacity not less than the water heater input rate as
shown on the model rating plate. (Electric heaters watts divided by 1000 x 3415 equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the
use of a temperature-pressure relief valve complying
vvith ANSI Z2I.22 and ASME, may require a valve model
different from the one furnished with the water heater.
Compliance with such local requirements must be satis
fied by the installer or end user of the water heater with
a locally prescribed temperature-pressure relief valve
installed in the designated opening in the water heater in
place of the factory furnished valve.
For safe operation of the water heater, the relief valve
must not be removed from it’s designated opening or
plugged.
The temperature-pressure relief valve must be Installed
directly into the fitting of the water heater designated for
the relief valve. Position the valve downward and provide
tubing so that any discharge will exit only within 6 inches
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
part. The discharge opening must not be blocked or
reduced in size under any circumstances. Excessive
length, over 30 feet, or use of more than four elbows can
cause restriction and reduce the discharge capacity of
the valve.
No valve or other obstruction is to be placed between
^
the relief valve and the tank. Do not connect tubing
directly to discharge drain unless a 6" air gap is provided.
To prevent bodily injury, hazard to life, or property dam
age, the relief valve must be allowed to discharge water
in quantities should circumstances demand. If the dis
charge pipe is not connected to a drain or other suitable
means, the water flow may cause property damage.
The Discharge Pipe:
• Must not be smaller in size than the outlet pipe size of
the valve, or have any reducing couplings or other
restrictions.
■ Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
• Must be installed so as to allow complete drainage of
both the temperature-pressure relief valve, and the dis
charge pipe.
• Must terminate at an adequate drain.
• Must not have any valve between the relief valve and
tank.
Safety
AWARNING
A gas water heater cannot operate properly without the
correct amount of air for combustion. Do not install in a
confined area such a closet, unless you provide air as
shown in the “Facts to Consider About the Location” sec
tion. Never obstruct the flow of ventilation air. If you have
any doubts or questions at all, call your gas company.
Failure to provide the proper amount of combustion air
can result in a fire or explosion and can cause DEATH,
SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
A WARNING
HOTTER WATER CAN SCALD; Water heaters are
intended to produce hot water. Water heated to a tem
perature which will satisfy clothes washing, dish washing,
and other sanitizing needs can scald and permanently
injure you upon contact. Some people are more likely to
be permanently injured by hot water than others. These
include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home
fits into one of these groups or if there is a local code or
state law requiring a certain temperature water at the hot
water tap, then you must take special precautions. In addi
tion to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a mixing
valve, should be used at the hot water taps used by these
people or at the water heater. Mixing valves are available
at plumbing supply or hardware stores. Follow manufac
turers instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
“Temperature Regulation’’ section in this manual.
A WARNING
Soot build-up indicates a problem that requires correc
tion before further use. Turn "OFF’’ gas to water heater
and leave “OFF" until repairs are made, because failure
to correct the cause of the sooting can result in a fire or
explosion causing DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
AWARNING
This water heater must not be installed directly on car
peting. Carpeting must be protected by a metal or wood
panel beneath the appliance extending beyond the full
width and depth of the appliance by at least 3 inches
(76.2mm) in any direction, or if the appliance is installed
in an alcove or closet, the entire floor must be covered by
the panel. Failure to heed this warning may result in a
fire hazard.
AWARNING
VENT DAMPERS - Any vent damper, whether it is operat
ed thermally or otherwise must be removed if its use
inhibits proper drafting of the water heater.
Thermally Operated Vent Dampers: Gas-fired water
heaters having thermal efficiency in excess of 80% may
produce a relatively low flue gas temperature. Such tem
peratures may not be high enough to properly open ther
mally operated vent dampers. This would cause spillage of
flue gases and may cause carbon monoxide poisoning.
Vent dampers must bear evidence of certification as com
plying with the latest edition of American National
Standard ANSI Z2I.68 (ANSI Z2I.66 & 67, respectively,
cover electrically and mechanically actuated vent
dampers). Before installation of any vent damper, consult
your local Sears Service Center or the gas utility for fur
ther information.
AWARNING
•The appliance and its individual shutoff valve must be dis
connected from the gas supply piping system during any
pressure testing of the gas system at test pressures in
excess of % pound per square inch (3.5kPa).
• The appliance must be isolated from the gas supply pip
ing system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping sys
tem at test pressures equal or less than '/: pound per
square inch (3.5kPa).
______________
BEFORE LIGHTING [PROPANE (L.P.) GAS WATER
HEATERS]: Propane (L.P.) gas is heavier than air. Should
there be a leak in the system, the gas will settle near the
ground. Basements, crawl spaces, skirted areas under
mobile homes (even when ventilated), closets and areas
below ground level will serve as pockets for the accumula
tion of this gas. Before attempting to light or relight the
water heater’s pilot or turning on a nearby electrical light
switch, be absolutely sure there is no accumulated gas in
the area. Search for odor of gas by sniffing at ground level
in the vicinity of the appliance. If odor is detected, follow
steps indicated at “For Your Safety” on the cover page of
this manual then leave the premises.
AWARNING
_______________
^
Chemical vapor corrosion of the flue and vent system
may occur if air for combustion contains certain chemical
vapors. Spray can propellants, cleaning solvents, refrigera
tor and air conditioner refrigerants, swimming pool
chemicals, calcium and sodium chloride, waxes, bleach,
and process chemicals are typical compounds which are
potentially corrosive.
AWARNING
Obstructed or deteriorated vent systems may present a
serious health risk or asphyxiation.
Safety Precautions continued on page 4
AWARNING
Safety
AWARNING
The water heater with draft hood installed must be prop
erly vented to a chimney which terminates outdoors.
Never operate the water heater unless it is vented to the
outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphyxiation.
AWARNING
Minimum clearances between the water heater and com
bustible construction are I" at the sides and rear, 4" at the
front, and 6" from the vent pipe. Clearance from the top
of the jacket is 18" on most models. Note that a lesser
dimension may be allowed on some models. Refer to the
label on the water heater adjacent to the gas control valve
for all clearances.
AWARNfNG
Do not use this appliance if any part of it has been under
water. Immediately call a Sears Service Technician to
inspect the appliance and to replace the gas control or any
part of the burner system which has been under water.
A CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of
the water heater must be accomplished in such a manner
that if the tank or any connections should leak, the flow of
water will not cause damage to the structure. For this
reason, it is not advisable to install the water heater in an
attic or upper floor. When such locations cannot be avoid
ed, a suitable drain pan should be installed under the
water heater. Drain pans are available at your local Sears
store. Such a drain pan must be not greater than I
es deep, have a minimum length and width of at least 2
inches greater than the water heater dimensions and
must be piped to an adequate drain. The pan must not
restrict combustion air flow. Under no circumstances is
the manufacturer or Sears to be held liable for any water
damage in connection with this water heater.
V% inch
AWARNING
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of
time (generally two weeks or more). Hydrogen gas is
extremely flammable and explosive. To prevent the possi
bility of injury under these conditions, we recommend the
hot water faucet be opened for several minutes at the
kitchen sink before any electrical appliances which are
connected to the hot water system are used (such as a
dishwasher or washing machine). If hydrogen gas is pre
sent, there will probably be an unusual sound similar to air
escaping through the pipe as the hot water faucet is
opened. There must be no smoking or open flame near
the faucet at the time it is open.
AWARNING
INSULATING JACKETS: When installing an external
water heater insulation jacket on a gas water heater:
• DO NOT cover the temperature-pressure relief valve.
• DO NOT put insulation over any part of the top of the
gas water heater.
• DO NOT put insulation over the gas control valve or gas
control valve/burner cover, or any access areas to the
burner.
• DO NOT let insulation around the gas water heater to
get within 8 inches of the floor (air must get to the
burner),
• DO NOT cover or remove operating instructions, and
safety related warning labels and materials affixed to the
water heater.
Failure to heed this will result in the possibility of a fire or
explosion.
Removing the Old Water Heater................................................................................................................................................................8
Facts to Consider About the Location........................................................................................................................................................9
Combustion Air and Ventilation for Appliances in Unconfined Spaces...................................................................................................10
Combustion Air and Ventilation for Appliances in Confined Spaces.......................................................................................................10
Water Piping..............................................................................................................................................................................................11
Filling the Water Heater........................................................................................................................................................................... 13
Gas Piping............................................................................................................................................................................................ 14-15
Temperature Regulation.......................................................................................................................................................................... 19
Service and Adjustment.......................................................................................................................................20-22
Tank (Sediment) Cleaning.........................................................................................................................................................................20
Venting System Inspection........................................................................................................................................................................ 20
Start Up Conditions....................................................................................................................................................................................22
“Air” in Hot Water Faucets.....................................................................................................................................................................23
High Temperature Shut Off System........................................................................................................................................................ 24
Not Enough Hot Water.......................................................................................................................................................................... 24
Water is too Hot.......................................................................................................................................................................................24
Parts Order List................................................................................26-27
Customer Responsibilities
Thank You for purchasing a Sears water hearer.
Properly installed and maintained, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears call the local Sears
Service Center or any Sears store. They will arrange for prompt,
quality installation by Sears authorized contractors.
Abbreviations Found In Tbis Instruction Manual
C.S.A. - Canadian Standards Association
A.N.S.I. - American National Standards Institute
N.F.P.A. - National Fire Protection Agency
A WARNING
This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National
Standard/CSA Standard for Gas Water Heaters ANS
Z21.10.1 • CSA 4.1 (latest edition). The installation must
conform with this manual, Local Codes and with the latest
edition of the National Fuel Gas Code, ANSI Z223.I.
This publication is available from your local government or
public library, gas company, or by writing NFPA,
Batterymarch Park, Quincy, MA 02269.
Read the “Safety Precautions” section, pages 2 through 4 of
this manual first and then the entire manual carefully. If you
don’t follow the safety rules, the water heater will not operate
properly. It could cause DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera
tion, and maintenance of the gas-fired water heater. It also
contains warnings through out the manual that you must read
and be aware of. All warnings and all instructions are essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, RFAD
THE ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; ps company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition of the National
Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54.
This publication is available from your local government or
public library or gas company or by writing NFPA,
Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe instal
lation are very important in preventing death from possible
carbon monoxide poisoning and fires.
Examine the location to ensure the water heater complies with
the “Facts to Consider about the Location” section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce
dures. Instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
Product Specifications
MODEL
NUMBER
153.330402
153.330452
153.330502
153.330552
153.330702
153.330752
TANK
CAPACITY
IN GALLONS
40
40
50
50
75
75
TYPE
OF
GAS
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
B.T.U.
RATE
40,000
40,000
40,000
40,000
55,000
55,000
RECOVERY RATE
GALS. PER HOUR
RISE
46.0
46.0
46.0
46.0
59.2
59.2
MINIMUM
VENT
PIPE
3” or 4"
3” or 4”
3” or 4"
3" or 4"
4"
4"
DIMENSIONS IN INCHES
HEIGHT TO
DIAMETER
18"
18"
20"
20"
24"
24”
JACKET TOP
60"
60"
59Z"
59/T
60"
60"
Materials and Basic Tools Needed
Materials Needed
To simplify the installation Sears has available the installation
parts shown below. You may or may not need all of these materi
als, depending on your type of installation.
WATER HEATER STAND 24"x24"xl8"
Gas
Water Heater
Installation
Kit
f II
,,i.L
I
E
I
?
e
í3
WATER HEATER INSTAL
LATION KIT WITH FLEXI
BLE CONNECTORS FOR
3/4" OR I/2" THREADED
OR COPPER PLUMBING
VENT ELBOW
c
EXPANSION TANKS
FOR THERMAL
EXPANSION CONDI
TIONS AVAILABLE IN
2 GALLON AND 5
GALLON CAPACITY
THROUGH LOCAL
SEARS STORE OR
SERVICE CENTERS
VENT PIPE
FLEXIBLE WATER
HEATER GAS CON
NECTOR WITH
FITTINGS
3^irt. H.P.T NurTap№pfVM
WATER HEATER HEAT
TRAPS HELP REDUCE HEAT
LOSS DUE TO THERMAL
SYPHONING
FOR USE WITH WATER HEATERS
INSTALLED IN RESIDENTIAL
GARAGES HAVING A DIAMETER 24"
OR LESS AND A RATED CAPACITY 7S
GALLONS OR LESS
DRAIN PANS AVAILABLE IN 20"
DIAMETER FOR WATER HEATERS
HAVING A DIAMETER 18" OR LESS,
24" DIAMETER FOR WATER HEATERS
HAVING A DIAMETER 22" OR LESS
AND AVAILABLE IN 28" DIAMETER
FOR WATER HEATERS HAVING A
DIAMETER 26" OR LESS
Basic Tools
You may or may not need all of these tools, depending on your
type of installation. These tools can be purchased at your local
Sears store.
• Pipe Wrenches (2) 14"
• Screwdriver
• Tin Snips
• 6 Foot Tape of Folding Rule
• Garden Hose
• Drill
• Pipe dope or Teflon Tape
GARDEN HOSE
SLOT-HEAD SCREWDRIVER
PHILLIPS SCREWDRIVER
PIPE DOPE (SQUEEZE TUBE)
(USE FOR WATER AND
GAS CONNECTIONS)
6 FOOT TAPE
ROLL OF TEFLON TAPE
(USE ONLY ON WATER
CONNECTIONS)
If the main gas line shutoff serving all gas appliances is
used, also shut “OFF” the gas at each appliance. Leave all
gas appliances shut “OFF” until the water heater installa
tion is complete.
^^Turn “OFF” the water to the water
heater. Some installations require that
the water be turned off to the entire
house.
Disconnect the vent pipe from the draft hood where
they connect to the water heater. In most installations
the vent pipe can be lifted off aftet any screw or other
attached devices are removed. Dispose of the draft
hood. The new water heater has the draft hood which
must be used for proper operation.
If you have copper piping to the water
heater, the two copper water pipes can
be cut with a hacksaw approximately 4"
away from where they connect to the
water heater. This will avoid cutting off
the pipes too short. Additional cuts can
be made later if necessary. Disconnect
the temperature-pressure relief valve
drain line. When the water heater is
drained, disconnect the hose from the
drain valve. Close the drain valve. The
water heater is now completely discon
nected and ready to be removed.
Check a^ain to make sure the gas supply
(3)
is “OFF to the water heater. Then dis
connect the gas supply connection from
the gas control valve.
valve and put the other end in a floor
drain or outdoors. Open the water heater
drain valve. Open a nearby hot water
faucet which will relieve pressure in the
water heater and speed draining.
AWARNING
The water passing out of the drain valve may be extremely
hot. To avoid being scalded, make sure all connections are
tight and that the water flow is directed away from any
person.
b. If you have galvanized pipe to the water
heater, loosen the two galvanized pipes
with a pipe wrench at the union in each
line. Also disconnect the piping remain
ing to the water heater. These pieces
should be saved since they may be need
ed when reconnecting the new water
heater. Disconnect the temperature-pres
sure relief valve dram line. When the
water heater is drained, disconnect the
hose from the drain valve. Close the
drain valve. The water heater is now
completely disconnected and ready to be
removed.
A CAUTION
Mineral buildup or sediment may have accumulated in the
old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could
cause staining.
Installation Instructions (cont’d)
Facts to Consider About the
Location
You should carefully choose an indoor location for the new
water heater, because the placement is a very important consid
eration for the safety of the occupants in the building and for
the most economical use of the appliance. This water heater is
not for use in mobile homes or outdoor installation.
Whether replacing an old water heater or putting the water
heater in a new location, the following cricical points must be
observed.
• The location selected should be indoors as close as practical
CO the gas vent or chimney to which the water heater vent is
going CO be connected, and as centralized with the water pip
ing system as possible. The water heater, as all water hearers,
will eventually leak. Do not install without adequate
drainage provisions where water flow will cause damage.
A CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of the
water heater nnust be accomplished in such a manner that if
the tank or any connections should leak, the flow of water will
not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan
should be installed under the water heater. Drain pans are avail
able at your local Sears store. Such a drain pan must be not
greater than I
% inches deep, have a minimum length and width
of at least 2 inches greater than the water heater dimensions
and must be piped to an adequate drain. The pan must not
restrict combustion air flow. Under no circumstances is the
manufacturer or Sears to be held liable for any water damage
in connection with this water heater.
AWARNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE, AND UTILITY AREAS, ETC);
Flammable liquids (such as gasoline, solvents, propane (LP) or
butane, etc.), all of which emit flammable vapors, may be
improperly stored or used in such areas. The gas water heater
pilot light or main burner can ignite such vapors. The resulting
flashback and fire can cause death or serious bums to anyone in
the area, as well as property damage.
If installation in such areas is your only option, then the installa
tion must be accomplished in a way that the pilot flame and
main burner flame are elevated from the floor at least 18 inches.
While this may reduce the chances of flammable vapors from a
floor spill being ignited, gasoline and other flammable substances
should never be stored or used in the same room or area con
taining a gas water heater or other open flame or spark produc
ing appliance.
NOTE; Flammable vapors may be drawn by air currents fram
other areas of the stmcture to the appliance.
AWARNING
Propellants of aerosol sprays and volatile compounds, (clean
ers, chlorine based chemicals, refrigerants, etc.) in addition to
being highly flammable in many cases, will also change to cor
rosive hydrochloric acid when exposed to the combustion
products of the water heater. The results can be hazardous,
and also cause product failure.
The location selection must provide adequate clearances for:
vicing and proper operation ol the water heater.
AWARNING
This water heater must not be installed directly on carpeting.
Carpeting must be protected by a metal or wood panel
beneath the appliance extending beyond the full width and
depth of the appliance by at least 3 inches (76.2mm) in any
direction, or if the appliance is installed in an alcove or closet,
the entire floor must be covered by the panel. Failure to heed
this warning may result in a fire hazard.
AWARNING
Minimum clearances between the water heater and com
bustible construction are I" at the sides and rear, 4" at the
front, and 6" from the vent pipe* Clearance from the top of the
jacket is 18" on most models. Note that a lesser dimension may
be allowed on some models. Refer to the label on the water
heater adjacent to the gas control valve for all clearances.
12“ MAX.
Figure I
VENTILATION
AIR ^
OPENINGS^
+
FRONT VIEW
OF DOOR
12" MAX.
TOP VIEW
OF CLOSET
WITHOUT DOOR
r hIN
TOP view'
OF CLOSET
WITH DOOR
AIR DUCT
3“
MIN.
’ MIN,
AWARNING
A gas water heater cannot operate properly without the cor
rect amount of air for combustion. Do not install in a confined
area such a closet, unless you provide air as shown in the “Facts
to Consider about the Location” section. Never obstruct the
flow of ventilation air. If you have any doubts or questions at all,
call your gas company. Failure to provide the proper amount of
combustion air can result in a fire or explosion and can cause
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
AWARNING
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas. Refer to the "Facts to
Consider About the Location" section of this manual and also
the latest edition of the National Fuel Gas Code, ANSI Z223.I,
also referred to as NFPA 54 for specifics provided concerning
air required.
Loading...